wireSensorResolution
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.8.4.1.9
Object
The resolution: the minimum difference between any two measured values The value of this OID variable should be scaled by wireSensorDecimalDigits. For example, if the value is 1 and wireSensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to sensors without numerical reading.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.8.4.1.9- Type
- column
- Access
- readonly
- Status
- obsolete
- Parent
- wireSensorConfigurationEntry
- Table
- wireSensorConfigurationTable
- Siblings
- 14
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wireSensorTolerance obsolete The tolerance: the maximum difference between measurement and the
actual value. The value of this OID variable should be scaled by
(wireSensorDecimalDigits + 1). For example, if t… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.10 |
| wireSensorMaximum obsolete The largest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
wireSensorDecimalDigits. For example, if the value is 1 and
wireSensorDecim… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.11 |
| wireSensorMinimum obsolete The smallest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
wireSensorDecimalDigits. For example, if the value is 1 and
wireSensorDeci… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.12 |
| wireSensorHysteresis obsolete The hysteresis used when crossing a threshold towards the normal state.
The value of this OID variable should be scaled by
wireSensorDecimalDigits. For example, if the value is 1 … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.13 |
| wireSensorStateChangeDelay obsolete The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon as
it is detected; if it is non-zero, say n, then the assertion
… | column | Unsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.14 |
| wireSensorLowerCriticalThreshold obsolete The lower critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
wireSensorDecimalDigits. For example, if the value is 1 and
wireSensorDecim… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.21 |
| wireSensorLowerWarningThreshold obsolete The lower warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
wireSensorDecimalDigits. For example, if the value is 1 and
wireSensorDecima… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.22 |
| wireSensorUpperCriticalThreshold obsolete The upper critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
wireSensorDecimalDigits. For example, if the value is 1 and
wireSensorDecim… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.23 |
| wireSensorUpperWarningThreshold obsolete The upper warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
wireSensorDecimalDigits. For example, if the value is 1 and
wireSensorDecima… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.24 |
| wireSensorEnabledThresholds obsolete A bit string indicating which thresholds are enabled.
This parameter does not apply to sensors without numerical reading. | column | Bits | .1.3.6.1.4.1.13742.6.3.8.4.1.25 |
| wireSensorLogAvailable obsolete Is data logging enabled for this sensor? | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.8.4.1.4 |
| wireSensorUnits obsolete The unit in which the sensor reading is reported.
This parameter does not apply to sensors without numerical reading. | column | SensorUnitsEnumeration | .1.3.6.1.4.1.13742.6.3.8.4.1.6 |
| wireSensorDecimalDigits obsolete The number of digits displayed to the right of the decimal point.
This parameter does not apply to sensors without numerical reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.8.4.1.7 |
| wireSensorAccuracy obsolete The accuracy: the maximum relative difference (in percent) between
measurement and the actual value.
This parameter does not apply to sensors without numerical reading. | column | HundredthsOfAPercentage | .1.3.6.1.4.1.13742.6.3.8.4.1.8 |