overCurrentProtectorSensorConfigurationEntry
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.4.4.1
Object
row
An entry containing over current protector sensor configuration objects.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.4.4.1- Type
- row
- Status
- current
- Parent
- overCurrentProtectorSensorConfigurationTable
- Table
- overCurrentProtectorSensorConfigurationTable
- Children
- 21
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| overCurrentProtectorSensorTolerance deprecated The tolerance: the maximum difference between measurement and the
actual value. The value of this OID variable should be scaled by
(overCurrentProtectorSensorDecimalDigits + 1). F… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.10 |
| overCurrentProtectorSensorMaximum The largest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.11 |
| overCurrentProtectorSensorMinimum The smallest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 an… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.12 |
| overCurrentProtectorSensorHysteresis The hysteresis used when crossing a threshold towards the normal state.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.13 |
| overCurrentProtectorSensorStateChangeDelay The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon as
it is detected; if it is non-zero, say n, then the assertion
… | column | Unsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.14 |
| overCurrentProtectorSensorLowerCriticalThreshold The lower critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.21 |
| overCurrentProtectorSensorLowerWarningThreshold The lower warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.22 |
| overCurrentProtectorSensorUpperCriticalThreshold The upper critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.23 |
| overCurrentProtectorSensorUpperWarningThreshold The upper warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.24 |
| overCurrentProtectorSensorEnabledThresholds A bit string indicating which thresholds are enabled.
This parameter does not apply to sensors without numerical reading. | column | Bits | .1.3.6.1.4.1.13742.6.3.4.4.1.25 |
| overCurrentProtectorSensorSignedMaximum The largest possible reading as a signed integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
ov… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.4.4.1.26 |
| overCurrentProtectorSensorSignedMinimum The smallest possible reading as a signed integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
o… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.4.4.1.27 |
| overCurrentProtectorSensorSignedLowerCriticalThreshold The lower critical threshold as a signed integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
ov… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.4.4.1.28 |
| overCurrentProtectorSensorSignedLowerWarningThreshold The lower warning threshold as a signed integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
ove… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.4.4.1.29 |
| overCurrentProtectorSensorSignedUpperCriticalThreshold The upper critical threshold as a signed integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
ov… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.4.4.1.30 |
| overCurrentProtectorSensorSignedUpperWarningThreshold The upper warning threshold as a signed integer.
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
ove… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.4.4.1.31 |
| overCurrentProtectorSensorLogAvailable Is data logging enabled for this sensor? | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.4.4.1.4 |
| overCurrentProtectorSensorUnits The unit in which the sensor reading is reported.
This parameter does not apply to sensors without numerical reading. | column | SensorUnitsEnumeration | .1.3.6.1.4.1.13742.6.3.4.4.1.6 |
| overCurrentProtectorSensorDecimalDigits The number of digits displayed to the right of the decimal point.
This parameter does not apply to sensors without numerical reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.7 |
| overCurrentProtectorSensorAccuracy deprecated The accuracy: the maximum relative difference (in percent) between
measurement and the actual value.
This parameter does not apply to sensors without numerical reading. | column | HundredthsOfAPercentage | .1.3.6.1.4.1.13742.6.3.4.4.1.8 |
| overCurrentProtectorSensorResolution The resolution: the minimum difference between any two measured values
The value of this OID variable should be scaled by
overCurrentProtectorSensorDecimalDigits. For example, if … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.4.4.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduId A unique value for each PDU or power meter.
For BCM2 and PMC, pduId can be:
- 0 for the main controller
- The meter ID (rotary switch) for power meter
For a… | column | Integer32 | .1.3.6.1.4.1.13742.6.3.2.1.1.1 |
| overCurrentProtectorIndex A unique value for each overcurrent protector. Its value
ranges between 1 and the value of overCurrentProtectorCount. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.4.3.1.1 |
| sensorType The type of sensor. | column | SensorTypeEnumeration | .1.3.6.1.4.1.13742.6.3.2.5.1.1 |