outletGroupSensorUpperCriticalThreshold
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.12.3.1.23
Object
The upper critical threshold as an unsigned integer. The value of this OID variable should be scaled by outletGroupSensorDecimalDigits. For example, if the value is 1 and outletGroupSensorDecimalDigits is 2, then actual value is 0.01. The value is clamped if the scaled threshold exceeds 4294967295. It is undefined for sensors which can have negative readings. This parameter does not apply to sensors without numerical reading.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.12.3.1.23- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- outletGroupSensorConfigurationEntry
- Table
- outletGroupSensorConfigurationTable
- Siblings
- 18
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| outletGroupSensorMaximum The largest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGr… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.11 |
| outletGroupSensorMinimum The smallest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletG… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.12 |
| outletGroupSensorHysteresis The hysteresis used when crossing a threshold towards the normal state.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the valu… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.13 |
| outletGroupSensorStateChangeDelay The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon as
it is detected; if it is non-zero, say n, then the assertion
… | column | Unsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.14 |
| outletGroupSensorLowerCriticalThreshold The lower critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGr… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.21 |
| outletGroupSensorLowerWarningThreshold The lower warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGro… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.22 |
| outletGroupSensorUpperWarningThreshold The upper warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGro… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.24 |
| outletGroupSensorEnabledThresholds A bit string indicating which thresholds are enabled.
This parameter does not apply to sensors without numerical reading. | column | Bits | .1.3.6.1.4.1.13742.6.3.12.3.1.25 |
| outletGroupSensorSignedMaximum The largest possible reading as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroup… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.26 |
| outletGroupSensorSignedMinimum The smallest possible reading as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGrou… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.27 |
| outletGroupSensorSignedLowerCriticalThreshold The lower critical threshold as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroup… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.28 |
| outletGroupSensorSignedLowerWarningThreshold The lower warning threshold as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroupS… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.29 |
| outletGroupSensorSignedUpperCriticalThreshold The upper critical threshold as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroup… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.30 |
| outletGroupSensorSignedUpperWarningThreshold The upper warning threshold as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroupS… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.31 |
| outletGroupSensorLogAvailable Is data logging enabled for this sensor? | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.12.3.1.4 |
| outletGroupSensorUnits The unit in which the sensor reading is reported.
This parameter does not apply to sensors without numerical reading. | column | SensorUnitsEnumeration | .1.3.6.1.4.1.13742.6.3.12.3.1.6 |
| outletGroupSensorDecimalDigits The number of digits displayed to the right of the decimal point.
This parameter does not apply to sensors without numerical reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.7 |
| outletGroupSensorResolution The resolution: the minimum difference between any two measured values
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.9 |