outletGroupSensorDecimalDigits
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.12.3.1.7
Object
column
SNMPv2-SMIUnsigned32
The number of digits displayed to the right of the decimal point. This parameter does not apply to sensors without numerical reading.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.12.3.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- outletGroupSensorConfigurationEntry
- Table
- outletGroupSensorConfigurationTable
- Siblings
- 18
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| outletGroupSensorMaximum The largest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGr… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.11 |
| outletGroupSensorMinimum The smallest possible reading as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletG… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.12 |
| outletGroupSensorHysteresis The hysteresis used when crossing a threshold towards the normal state.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the valu… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.13 |
| outletGroupSensorStateChangeDelay The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon as
it is detected; if it is non-zero, say n, then the assertion
… | column | Unsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.14 |
| outletGroupSensorLowerCriticalThreshold The lower critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGr… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.21 |
| outletGroupSensorLowerWarningThreshold The lower warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGro… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.22 |
| outletGroupSensorUpperCriticalThreshold The upper critical threshold as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGr… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.23 |
| outletGroupSensorUpperWarningThreshold The upper warning threshold as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGro… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.24 |
| outletGroupSensorEnabledThresholds A bit string indicating which thresholds are enabled.
This parameter does not apply to sensors without numerical reading. | column | Bits | .1.3.6.1.4.1.13742.6.3.12.3.1.25 |
| outletGroupSensorSignedMaximum The largest possible reading as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroup… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.26 |
| outletGroupSensorSignedMinimum The smallest possible reading as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGrou… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.27 |
| outletGroupSensorSignedLowerCriticalThreshold The lower critical threshold as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroup… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.28 |
| outletGroupSensorSignedLowerWarningThreshold The lower warning threshold as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroupS… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.29 |
| outletGroupSensorSignedUpperCriticalThreshold The upper critical threshold as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroup… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.30 |
| outletGroupSensorSignedUpperWarningThreshold The upper warning threshold as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroupS… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.12.3.1.31 |
| outletGroupSensorLogAvailable Is data logging enabled for this sensor? | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.12.3.1.4 |
| outletGroupSensorUnits The unit in which the sensor reading is reported.
This parameter does not apply to sensors without numerical reading. | column | SensorUnitsEnumeration | .1.3.6.1.4.1.13742.6.3.12.3.1.6 |
| outletGroupSensorResolution The resolution: the minimum difference between any two measured values
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.12.3.1.9 |