measurementsInletSensorIsAvailable
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.5.2.3.1.2
Object
column
SNMPv2-TCTruthValue
The sensor is present.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.5.2.3.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- inletSensorMeasurementsEntry
- Table
- inletSensorMeasurementsTable
- Siblings
- 12
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| measurementsInletSensorMinTimeStamp The timestamp of last change of the minimum value of sensor reading
provided as measurementInletSensor[Signed]MinValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.3.1.10 |
| measurementsInletSensorMaxValue The maximum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
inletSensorDecimalDigits. For example, if the value … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.3.1.11 |
| measurementsInletSensorSignedMaxValue The maximum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
inletSensorDecimalDigits. For example, if the value is … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.3.1.12 |
| measurementsInletSensorMaxTimeStamp The timestamp of last change of the maximum value of sensor reading
provided as measurementInletSensor[Signed]MaxValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.3.1.13 |
| measurementsInletSensorMinMaxResetTimeStamp The timestamp of last reset of all minimum and maximum values of sensor reading
including their timestamps, provided as measurementsInletSensor[Signed]{Min|Max}{Value|TimeStamp}
a… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.3.1.14 |
| measurementsInletSensorState The sensor state. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.5.2.3.1.3 |
| measurementsInletSensorValue The sensor reading as an unsigned integer.
The value of this OID variable should be scaled by
inletSensorDecimalDigits. For example, if the value is 1 and
inletSensorDecimalDigits… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.3.1.4 |
| measurementsInletSensorTimeStamp The timestamp for reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.3.1.5 |
| measurementsInletSensorSignedValue The sensor reading as a signed integer.
The value of this OID variable should be scaled by
inletSensorDecimalDigits. For example, if the value is 1 and
inletSensorDecimalDigits is… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.3.1.6 |
| measurementsInletSensorMinMaxValid The minimum and maximum values of sensor reading and their timestamps
provided as measurementsInletSensor[Signed]{Min|Max}{Value|TimeStamp} are valid | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.2.3.1.7 |
| measurementsInletSensorMinValue The minimum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
inletSensorDecimalDigits. For example, if the value … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.3.1.8 |
| measurementsInletSensorSignedMinValue The minimum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
inletSensorDecimalDigits. For example, if the value is … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.3.1.9 |