circuitPoleSensorStateChange
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.0.104
Object
notification
BCM2/PMC circuit pole sensor state change. Which value field to use depends on the metadata of the sensor. measurementsCircuitPoleSensorValue is undefined for sensors which can have negative readings, measurementsCircuitPoleSensorSignedValue is undefined for sensors whose range exceeds the Integer32 range. Both fields do not apply to sensors without numerical readings.
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| trapInformation | node | - | .1.3.6.1.4.1.13742.6.0.0 |
| systemStarted The system has started. | notification | - | .1.3.6.1.4.1.13742.6.0.1 |
| peripheralDeviceFirmwareUpdate The firmware update state of a peripheral device changed while
performing update to peripheralDevicePackageFirmwareVersion. | notification | - | .1.3.6.1.4.1.13742.6.0.100 |
| unitSensorReset An unit sensor was reset. | notification | - | .1.3.6.1.4.1.13742.6.0.101 |
| unitSensorStateChange Unit-level sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsUnitSensorValue is undefined for sensors which can
have negative readin… | notification | - | .1.3.6.1.4.1.13742.6.0.102 |
| circuitSensorStateChange BCM2/PMC branch circuit sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsCircuitSensorValue is undefined for sensors which can
have… | notification | - | .1.3.6.1.4.1.13742.6.0.103 |
| circuitAdded A new branch circuit has been configured | notification | - | .1.3.6.1.4.1.13742.6.0.105 |
| circuitDeleted A configured branch circuit has been deleted | notification | - | .1.3.6.1.4.1.13742.6.0.106 |
| circuitModified A configured branch circuit has been modified | notification | - | .1.3.6.1.4.1.13742.6.0.107 |
| circuitSensorReset An circuit sensor was reset. | notification | - | .1.3.6.1.4.1.13742.6.0.108 |
| powerMeterAdded A new power meter or panel has been configured | notification | - | .1.3.6.1.4.1.13742.6.0.109 |
| userAdded A user account was added to the system. | notification | - | .1.3.6.1.4.1.13742.6.0.11 |
| powerMeterDeleted A configured power meter has been deleted | notification | - | .1.3.6.1.4.1.13742.6.0.110 |
| powerMeterModified A configured power meter has been modified | notification | - | .1.3.6.1.4.1.13742.6.0.111 |
| smsMessageTransmissionFailure Sending an SMS message failed. | notification | - | .1.3.6.1.4.1.13742.6.0.112 |
| smartCardInserted A smartcard was inserted into a card reader. | notification | - | .1.3.6.1.4.1.13742.6.0.113 |
| smartCardRemoved A smartcard was removed from a card reader. | notification | - | .1.3.6.1.4.1.13742.6.0.114 |
| rawConfigurationDownloaded The raw configuration was downloaded from the device. | notification | - | .1.3.6.1.4.1.13742.6.0.115 |
| rawConfigurationUpdated A raw configuration update was applied on the device. | notification | - | .1.3.6.1.4.1.13742.6.0.116 |
| hwFailureStatusChanged A hardware component's failure state has changed. | notification | - | .1.3.6.1.4.1.13742.6.0.117 |
| outletGroupAdded A new outlet group has been configured | notification | - | .1.3.6.1.4.1.13742.6.0.118 |
| outletGroupModified A configured outlet group has been modified | notification | - | .1.3.6.1.4.1.13742.6.0.119 |
| userModified A user account was modified. | notification | - | .1.3.6.1.4.1.13742.6.0.12 |
| outletGroupDeleted A configured outlet group has been deleted | notification | - | .1.3.6.1.4.1.13742.6.0.120 |
| outletGroupSensorStateChange Outlet group sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsOutletGroupSensorValue is undefined for sensors which can
have negati… | notification | - | .1.3.6.1.4.1.13742.6.0.121 |
| outletGroupSensorReset An outlet group sensor was reset. | notification | - | .1.3.6.1.4.1.13742.6.0.122 |
| outletGroupPowerControl An outlet group switching operation has been performed. | notification | - | .1.3.6.1.4.1.13742.6.0.123 |
| serverPowerControlInitiated A server power control operation was initiated. | notification | - | .1.3.6.1.4.1.13742.6.0.124 |
| serverPowerControlCompleted A server power control operation has completed. | notification | - | .1.3.6.1.4.1.13742.6.0.125 |
| webcamStorageUploadStarted A new snapshot upload to webcam storage has started. | notification | - | .1.3.6.1.4.1.13742.6.0.126 |
| testEventTriggered A test event was triggered. | notification | - | .1.3.6.1.4.1.13742.6.0.127 |
| actuatorSwitched An actuator control operation has been performed. | notification | - | .1.3.6.1.4.1.13742.6.0.128 |
| keypadPinEntered A PIN was entered into a keypad. | notification | - | .1.3.6.1.4.1.13742.6.0.129 |
| userDeleted A user account was deleted from the system. | notification | - | .1.3.6.1.4.1.13742.6.0.13 |
| doorAccessGranted Door access was granted. | notification | - | .1.3.6.1.4.1.13742.6.0.130 |
| doorAccessDenied Door access was denied. | notification | - | .1.3.6.1.4.1.13742.6.0.131 |
| doorAccessRuleAdded A door access rule was added. | notification | - | .1.3.6.1.4.1.13742.6.0.132 |
| doorAccessRuleChanged A door access rule was changed. | notification | - | .1.3.6.1.4.1.13742.6.0.133 |
| doorAccessRuleDeleted A door access rule was deleted. | notification | - | .1.3.6.1.4.1.13742.6.0.134 |
| inletLinePairSensorStateChange Inlet line pair sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsInletLinePairSensorValue is undefined for sensors which can
have n… | notification | - | .1.3.6.1.4.1.13742.6.0.135 |
| tacPlusError A TACACS+ error occurred; errorDescription describes the error | notification | - | .1.3.6.1.4.1.13742.6.0.136 |
| outletSuspended An outlet was suspended after being suspected to have caused an OCP trip event. | notification | - | .1.3.6.1.4.1.13742.6.0.137 |
| userRenamed A user account was renamed. | notification | - | .1.3.6.1.4.1.13742.6.0.138 |
| roleAdded A role was added to the system. | notification | - | .1.3.6.1.4.1.13742.6.0.14 |
| roleModified A role was modified. | notification | - | .1.3.6.1.4.1.13742.6.0.15 |
| inletDipEvent Dip event on the inlet voltage sensor. | notification | - | .1.3.6.1.4.1.13742.6.0.151 |
| inletSwellEvent Dip event on the inlet voltage sensor. | notification | - | .1.3.6.1.4.1.13742.6.0.152 |
| inletPoleDipEvent Dip event on the voltage sensor of an inlet pole. | notification | - | .1.3.6.1.4.1.13742.6.0.153 |
| inletPoleSwellEvent Swell event on the voltage sensor of an inlet pole. | notification | - | .1.3.6.1.4.1.13742.6.0.154 |
| portFuseStateChange The state of a port fuse changed. | notification | - | .1.3.6.1.4.1.13742.6.0.155 |
| roleDeleted A role was deleted from the system. | notification | - | .1.3.6.1.4.1.13742.6.0.16 |
| systemReset The system was rebooted. | notification | - | .1.3.6.1.4.1.13742.6.0.2 |
| deviceUpdateStarted The device firmware update has started. | notification | - | .1.3.6.1.4.1.13742.6.0.20 |
| deviceUpdateCompleted The device firmware update has completed. | notification | - | .1.3.6.1.4.1.13742.6.0.21 |
| userBlocked A blocked user tried to log in. | notification | - | .1.3.6.1.4.1.13742.6.0.22 |
| powerControl An outlet switching operation has been performed.
Note that measurementsOutletSensorState represents the state of the outlet at the time the trap was sent.
This may be different f… | notification | - | .1.3.6.1.4.1.13742.6.0.23 |
| userPasswordChanged User password was changed. | notification | - | .1.3.6.1.4.1.13742.6.0.24 |
| passwordSettingsChanged Strong password settings changed. | notification | - | .1.3.6.1.4.1.13742.6.0.28 |
| userLogin A user logged in. | notification | - | .1.3.6.1.4.1.13742.6.0.3 |
| firmwareValidationFailed Validation of an uploaded firmware image failed. | notification | - | .1.3.6.1.4.1.13742.6.0.38 |
| userLogout A user logged out. | notification | - | .1.3.6.1.4.1.13742.6.0.4 |
| logFileCleared The event log has been cleared. | notification | - | .1.3.6.1.4.1.13742.6.0.41 |
| userAuthenticationFailure A user authentication attempt failed. | notification | - | .1.3.6.1.4.1.13742.6.0.5 |
| bulkConfigurationSaved A bulk configuration file was downloaded from the device. | notification | - | .1.3.6.1.4.1.13742.6.0.53 |
| bulkConfigurationCopied A bulk configuration file was copied to the device. | notification | - | .1.3.6.1.4.1.13742.6.0.54 |
| pduSensorStateChange deprecated Unit-level sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsUnitSensorValue is undefined for sensors which can
have negative readin… | notification | - | .1.3.6.1.4.1.13742.6.0.60 |
| inletSensorStateChange Inlet sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsInletSensorValue is undefined for sensors which can
have negative readings, … | notification | - | .1.3.6.1.4.1.13742.6.0.61 |
| inletPoleSensorStateChange Inlet pole sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsInletPoleSensorValue is undefined for sensors which can
have negative r… | notification | - | .1.3.6.1.4.1.13742.6.0.62 |
| outletSensorStateChange Outlet sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsOutletSensorValue is undefined for sensors which can
have negative readings… | notification | - | .1.3.6.1.4.1.13742.6.0.63 |
| outletPoleSensorStateChange Outlet pole sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsOutletPoleSensorValue is undefined for sensors which can
have negative… | notification | - | .1.3.6.1.4.1.13742.6.0.64 |
| overCurrentProtectorSensorStateChange Overcurrent protector sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsOverCurrentProtectorSensorValue is undefined for sensors whi… | notification | - | .1.3.6.1.4.1.13742.6.0.65 |
| externalSensorStateChange External sensor state change. | notification | - | .1.3.6.1.4.1.13742.6.0.66 |
| smtpMessageTransmissionFailure SMTP message transmission failure | notification | - | .1.3.6.1.4.1.13742.6.0.67 |
| ldapError An LDAP error occurred; errorDescription describes the error | notification | - | .1.3.6.1.4.1.13742.6.0.68 |
| deviceUpdateFailed The device firmware update has failed. | notification | - | .1.3.6.1.4.1.13742.6.0.70 |
| loadSheddingModeEntered The PDU has entered load shedding mode | notification | - | .1.3.6.1.4.1.13742.6.0.71 |
| loadSheddingModeExited The PDU has exited load shedding mode | notification | - | .1.3.6.1.4.1.13742.6.0.72 |
| pingServerEnabled The ping feature has been enabled for a server. | notification | - | .1.3.6.1.4.1.13742.6.0.73 |
| pingServerDisabled The ping feature has been disabled for a server. | notification | - | .1.3.6.1.4.1.13742.6.0.74 |
| serverNotReachable A monitored server has become unreachable. | notification | - | .1.3.6.1.4.1.13742.6.0.75 |
| serverReachable A monitored server has become reachable. | notification | - | .1.3.6.1.4.1.13742.6.0.76 |
| rfCodeTagConnected deprecated An RF-Code tag has been connected. | notification | - | .1.3.6.1.4.1.13742.6.0.77 |
| rfCodeTagDisconnected deprecated An RF-Code tag has been disconnected. | notification | - | .1.3.6.1.4.1.13742.6.0.78 |
| deviceIdentificationChanged A device identification parameter has been changed. | notification | - | .1.3.6.1.4.1.13742.6.0.79 |
| userSessionTimeout A user session timed out. | notification | - | .1.3.6.1.4.1.13742.6.0.8 |
| usbExpansionUnitConnected Connectivity to downstream expansion unit has been established.
It applies to the following interfaces:
USB
Ethernet
This trap is sent only if deviceCascadeType is portFor… | notification | - | .1.3.6.1.4.1.13742.6.0.80 |
| usbExpansionUnitDisconnected Connectivity to downstream expansion unit has been lost
It applies to the following interfaces:
USB
Ethernet
This trap is sent only if deviceCascadeType is portForwarding | notification | - | .1.3.6.1.4.1.13742.6.0.81 |
| lhxSupportChanged deprecated Schroff LHX support has been enabled or disabled. | notification | - | .1.3.6.1.4.1.13742.6.0.82 |
| userAcceptedRestrictedServiceAgreement A user accepted the Restricted Service Agreement. | notification | - | .1.3.6.1.4.1.13742.6.0.83 |
| userDeclinedRestrictedServiceAgreement A user declined the Restricted Service Agreement. | notification | - | .1.3.6.1.4.1.13742.6.0.84 |
| wireSensorStateChange obsolete Wire sensor state change. | notification | - | .1.3.6.1.4.1.13742.6.0.85 |
| transferSwitchSensorStateChange Transfer switch sensor state change.
Which value field to use depends on the metadata of the sensor.
measurementsTransferSwitchSensorValue is undefined for sensors which can
have … | notification | - | .1.3.6.1.4.1.13742.6.0.86 |
| deviceSettingsSaved A configuration backup has been downloaded from the device. | notification | - | .1.3.6.1.4.1.13742.6.0.88 |
| deviceSettingsRestored A configuration backup has been restored to the device. | notification | - | .1.3.6.1.4.1.13742.6.0.89 |
| webcamInserted A webcam has been connected. | notification | - | .1.3.6.1.4.1.13742.6.0.90 |
| webcamRemoved A webcam has been disconnected. | notification | - | .1.3.6.1.4.1.13742.6.0.91 |
| inletEnabled PDU operation has been enabled for an inlet | notification | - | .1.3.6.1.4.1.13742.6.0.92 |
| inletDisabled PDU operation has been disabled for an inlet | notification | - | .1.3.6.1.4.1.13742.6.0.93 |
| serverConnectivityUnrecoverable The connection to a monitored server could not be recovered. | notification | - | .1.3.6.1.4.1.13742.6.0.94 |
| radiusError A Radius error occurred; errorDescription describes the error | notification | - | .1.3.6.1.4.1.13742.6.0.95 |
| serverReachabilityError Server reachability error occurred; errorDescription describes the error.
This trap is sent when the Error state is entered.
Reasons for transitioning to the Error state include t… | notification | - | .1.3.6.1.4.1.13742.6.0.96 |
| inletSensorReset An inlet sensor was reset. | notification | - | .1.3.6.1.4.1.13742.6.0.97 |
| outletSensorReset An outlet sensor was reset. | notification | - | .1.3.6.1.4.1.13742.6.0.98 |
| unknownPeripheralDeviceAttached An unsupported peripheral device was attached. | notification | - | .1.3.6.1.4.1.13742.6.0.99 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduName The user-defined name for the PDU. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.2.2.1.13 |
| pduNumber A unique value for each PDU or power meter. This is the same as
pduId, but for use in traps.
For BCM2 and PMC, pduNumber can be:
- 0 for the main controller
- T… | scalar | Integer32 | .1.3.6.1.4.1.13742.6.0.0.3 |
| pxInetAddressType deprecated The type of address format
This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293). | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.13742.6.3.2.2.1.50 |
| pxInetIPAddress deprecated The current IP address. A value of 0.0.0.0 indicates an error
or an unset option.
This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293).
For IPv6, its val… | column | INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.13742.6.3.2.2.1.51 |
| agentInetPortNumber The UDP port number used for accessing the SNMP agent on the device.
This is necessary to identify the expansion unit in a port forwarding cascade. | scalar | INET-ADDRESS-MIBInetPortNumber | .1.3.6.1.4.1.13742.6.0.0.18 |
| circuitNumber A unique value for each circuit. Defined as follows:
circuitNumber = 1000 * panelId + circuitPosition
Examples:
1045 is the the circuit on panel 1 with lowest circuit p… | scalar | Integer32 | .1.3.6.1.4.1.13742.6.0.0.21 |
| circuitPoleNumber A unique value for each circuit pole. | scalar | Integer32 | .1.3.6.1.4.1.13742.6.0.0.22 |
| typeOfSensor The type of sensor. | scalar | SensorTypeEnumeration | .1.3.6.1.4.1.13742.6.0.0.10 |
| measurementsCircuitPoleSensorTimeStamp The timestamp for reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.8.4.1.5 |
| measurementsCircuitPoleSensorValue The sensor reading as an unsigned integer.
The value of this OID variable should be scaled by
circuitPoleSensorDecimalDigits. For example, if the value is 1 and
circuitPoleSensorD… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.8.4.1.4 |
| measurementsCircuitPoleSensorState The sensor state. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.5.8.4.1.3 |
| measurementsCircuitPoleSensorSignedValue The sensor reading as a signed integer.
The value of this OID variable should be scaled by
circuitPoleSensorDecimalDigits. For example, if the value is 1 and
circuitPoleSensorDeci… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.8.4.1.6 |
| oldSensorState The old sensor state used in sensor state transition traps. | scalar | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.0.0.2 |
| RFC1213-MIBsysContact mandatory The textual identification of the contact person
for this managed node, together with information
on how to contact this person. | scalar | OctetString | .1.3.6.1.2.1.1.4 |
| RFC1213-MIBsysName mandatory An administratively-assigned name for this
managed node. By convention, this is the node's
fully-qualified domain name. | scalar | OctetString | .1.3.6.1.2.1.1.5 |
| RFC1213-MIBsysLocation mandatory The physical location of this node (e.g.,
`telephone closet, 3rd floor'). | scalar | OctetString | .1.3.6.1.2.1.1.6 |
| pduSerialNumber The PDU serial number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.2.1.1.4 |