newSpectrumMgmtLoopMeasurementMethod

PDN-SPECTRUMMGMT-MIB · .1.3.6.1.4.1.1795.2.24.2.6.19.2.1.1.3

Object

column Enumeration
This object indicates the measurement method used in
describing the Loop Length of a circuit. Following are the
details of each of the options:
              
    none(1)       - Indicates that the Spectral Compliance
                    is NOT dependant on any Loop Length
                    measurements or configurations.
    loopLength(2) - The 'ConfLoopLength' object is used to
                    determine spectral compliance. The
                    'ConfEWL' & 'ConfQuadMode' objects are
                    not used in this mode.
    ewl(3)        - The 'ConfEWL' object is used to
                    configure the estimated loop length,
                    which is used to determine spectral
                    compliance. In this mode the
                    'ConfLoopLength' & 'ConfQuadMode'
                    objects are not used.
    quadMode(4)   - The 'ConfQuadMode' object is used to
                    determine spectral compliance. The
                    'ConfEWL' & 'ConfLoopLength' objects
                    are not used in this mode.
              
This object determines which of the three objects :
'ConfEWL', 'ConfLoopLength' or 'ConfQuadMode' is used
(if any) to enforce spectrally compliant maximum
'Tx Rates' and the maximum allowed 'Tx Power' on a given
circuit.

Context

MIB
PDN-SPECTRUMMGMT-MIB
OID
.1.3.6.1.4.1.1795.2.24.2.6.19.2.1.1.3
Type
column
Access
readonly
Status
current
Parent
newSpectrumMgmtGeneralConfigEntry
Table
newSpectrumMgmtGeneralConfigTable
Siblings
3

Syntax

Enumeration

Values & Constraints

Enumerated Values
1none
2loopLength
3ewl
4quadMode