ostLinkAggrPortCfgActiveNum

OMNITRON-LAG-MIB · .1.3.6.1.4.1.7342.18.2.1.5

Object

column r/w SNMPv2-SMIUnsigned32
This object selects number of active ports in a link aggregation
group as indicated by the associated port number.
              
If the number of active ports in a link aggregation group is equal
or greater than the number of ports in the group all ports can be
active.
              
If the number of active port in a link aggregation group is less
than the number of ports in a group one or more of the ports
have to be select as 'standby'.
              
Ports selected for standby are those that ports that don't have a
link, don't have a peer partner, or their port priority is less than
the other ports in a group.
              
From 802.1AX 2008:
Every link between systems operating LACP is assigned a unique
priority. This priority comprises (in priority order) the System
Priority, System ID, Port Priority, and Port Number of the higher-
priority system. In priority comparisons, numerically lower values
have higher priority.
              
Ports are considered for active use in an aggregation in link priority
order, starting with the port attached to the highest priority link.
Each port is selected for active use if preceding higher priority
selections can also be maintained; otherwise, the port is selected
as standby.

Context

MIB
OMNITRON-LAG-MIB
OID
.1.3.6.1.4.1.7342.18.2.1.5
Type
column
Access
readwrite
Status
current
Parent
ostLinkAggrPortCfgEntry
Table
ostLinkAggrPortCfgTable
Siblings
9

Syntax

SNMPv2-SMIUnsigned32
Source
SNMPv2-SMIUnsigned32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects