portBsciAdminCallInfoInRequestPacket
NETLINK-SPECIFIC-MIB ·
.1.3.6.1.4.1.173.7.3.4.1.1.11
Object
column
mandatory
r/w
Enumeration
Specifies whether the user will have the option of including call information in a call request packet.
Context
- MIB
- NETLINK-SPECIFIC-MIB
- OID
.1.3.6.1.4.1.173.7.3.4.1.1.11- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- portBsciAdminEntry
- Table
- portBsciAdminTable
- Siblings
- 29
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | no |
2 | yes |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| portBsciAdminBlockedFlag mandatory Causes the port to be enabled or disabled at node IPL. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.1 |
| portBsciAdminUseEBCDIC mandatory Specifies whether all devices on a line use the same
character set for successive session polls. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.10 |
| portBsciAdminClearVCOnLastDeviceDown mandatory Causes the virtual circuit to be cleared when no
terminals are using it. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.12 |
| portBsciAdminTransTextSupported mandatory Causes all characters transmitted to be treated as data. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.13 |
| portBsciAdminEndToEndAck mandatory Allows management of acknowledgments end to end across
the network rather than locally at each end. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.14 |
| portBsciAdminFullDuplex mandatory Specifies full-duplex transmission. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.15 |
| portBsciAdminMultidrop mandatory Specifies whether transmission will be multidrop. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.16 |
| portBsciAdminSlowPollRetryCount mandatory Specifies how many times the control unit will be polled
before it is put on the slow poll list. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.17 |
| portBsciAdminSlowPollRetryFreq mandatory Specifies the number of times active control units will
be polled between pollings on the slow poll list. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.18 |
| portBsciAdminStartSynchChars mandatory Specifies the number of synchronization characters
that will be added to the beginning of each frame. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.19 |
| portBsciAdminConnector mandatory Physical port interface connector type. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.2 |
| portBsciAdminEndPadChars mandatory Specifies the number of padding characters that will
be added to the end of each frame. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.20 |
| portBsciAdminPollInterval mandatory Specifies the time between passes through the polling list. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.21 |
| portBsciAdminNoResponseTimer mandatory Activated after transmission of a general poll or a
data frame. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.22 |
| portBsciAdminNoResponseRetryCount mandatory Specifies how many times the user device will be polled
before control is passed on the next cluster. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.23 |
| portBsciAdminErrorRetransmitCount mandatory Specifies the number of times the Netlink device will
resend a block of data after the receiving device has
detected an error in that block. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.24 |
| portBsciAdminNAKRetryCount mandatory Specifies the number of times the Netlink device will
send a frame when the receiving device is unable to
acknowledge. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.25 |
| portBsciAdminBlockCheck mandatory Sets the redundancy check parameter. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.26 |
| portBsciAdminDataMode mandatory Sets the parity parameter. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.27 |
| portBsciAdminRowStatus mandatory This variable is used to manage the creation and deletion
of conceptual rows in the portBsciAdminTable and follows the
SNMPv2 RowStatus conventions by supporting the following val… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.173.7.3.4.1.1.28 |
| portBsciAdminAnswerNonConfigured mandatory Only valid if pad type is HPAD. If yes, the HPAD will
respond to all devices on the line. If no, the HPAD will
respond only to those devices that are configured on the
node. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.29 |
| portBsciAdminSpeed mandatory Data transmission rate in bits per second. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.3 |
| portBsciAdminActivateConnectionWithoutPoll mandatory Only valid if pad type is TPAD. If yes, will active the
TPAD connection without a poll of the connected device. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.30 |
| portBsciAdminRetransmitInterval mandatory Length of time before the node will transmit an I-frame
if the previous transmission is not acknowledged. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.4 |
| portBsciAdminMAXRetransmits mandatory Maximum number of times the node will attempt to send
an I-frame after a retransmission period expiration. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.5 |
| portBsciAdminMaxBytesPerFrame mandatory Maximum frame size that will be transmitted on the port. | column | Integer32 | .1.3.6.1.4.1.173.7.3.4.1.1.6 |
| portBsciAdminGenerateClock mandatory Specifies whether the port will generate the clock
necessary to synchronize traffic over the link. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.7 |
| portBsciAdminRcvClockFromDTE mandatory Allows the clock to be looped back from the DTE
using the TT (Terminal Timing) signal. | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.8 |
| portBsciAdminPadType mandatory BSCI Pad Type | column | Enumeration | .1.3.6.1.4.1.173.7.3.4.1.1.9 |