softwareCuRepSwPackagesMissing

LUM-SOFTWARE-MIB · .1.3.6.1.4.1.8708.2.28.2.8.6

Object

scalar LUM-TCFaultStatus
Software package file(s) are missing on master CU.
          
When replacing or introducing CU or TU units some software
packages needs to be downloaded to the master CU in order to
automatically upgrade the software running on the replacement
unit.
          
Please perform an upgrade (or download) to current
enm-release spec file (without rebooting). The alarm should
then be cleared within 5 minutes.
Note that when this alarm is cleared, the alarm 'SW not
distributed' might be seen in up to approximately 5 minutes
before the system has assured that CU SW packages are
transferred to TU units.

Context

MIB
LUM-SOFTWARE-MIB
OID
.1.3.6.1.4.1.8708.2.28.2.8.6
Type
scalar
Access
readonly
Status
current
Parent
softwareCuRep
Siblings
7

Syntax

LUM-TCFaultStatus
Source
LUM-TCFaultStatus
Base type
Enumeration

Values & Constraints

Type Values
1ok
2alarm

Related Objects

Sibling Objects