softwareCuRepSwPackagesMissing
LUM-SOFTWARE-MIB ·
.1.3.6.1.4.1.8708.2.28.2.8.6
Object
scalar
LUM-TCFaultStatus
Software package file(s) are missing on master CU.
When replacing or introducing CU or TU units some software
packages needs to be downloaded to the master CU in order to
automatically upgrade the software running on the replacement
unit.
Please perform an upgrade (or download) to current
enm-release spec file (without rebooting). The alarm should
then be cleared within 5 minutes.
Note that when this alarm is cleared, the alarm 'SW not
distributed' might be seen in up to approximately 5 minutes
before the system has assured that CU SW packages are
transferred to TU units.
Context
- MIB
- LUM-SOFTWARE-MIB
- OID
.1.3.6.1.4.1.8708.2.28.2.8.6- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- softwareCuRep
- Siblings
- 7
Values & Constraints
Type Values
1 | ok |
2 | alarm |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| softwareCuRepAdminStatus The administrative state for the alarm.
down - No alarm will be rasied if SW packages are missing.
service - No alarm will be rasied if SW packages are missi… | scalar | LUM-TCBoardOrInterfaceAdminStatus | .1.3.6.1.4.1.8708.2.28.2.8.1 |
| softwareCuRepUnSaved If the configuration is saved or not. | scalar | Enumeration | .1.3.6.1.4.1.8708.2.28.2.8.2 |
| softwareCuRepSystemMode If dipswitch is changed or not. | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.28.2.8.3 |
| softwareCuRepRebootCu If the CU should be rebooted or not. | scalar | Enumeration | .1.3.6.1.4.1.8708.2.28.2.8.4 |
| softwareCuRepOkConfigure Configure an CU that has correct SW.
Run automatically when in CU replacement mode
when CU is an CU-SFP AND SW is correct.
Asks for the following:
Configuration not sav… | scalar | LUM-TCCommandString | .1.3.6.1.4.1.8708.2.28.2.8.5 |
| softwareCuRepSwNotDistributed Some SW package(s) needed to perform a CU replacement with
automatic upgrade are not transferred to a traffic unit. This
means that CU replacement with auto-upgrade will not work … | scalar | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.28.2.8.7 |
| softwareCuRepSupportedReplacements The types of control unit boards which should be supported as
replacements for the current main control unit.