softwareCuRepSwNotDistributed
LUM-SOFTWARE-MIB ·
.1.3.6.1.4.1.8708.2.28.2.8.7
Object
scalar
LUM-TCFaultStatus
Some SW package(s) needed to perform a CU replacement with
automatic upgrade are not transferred to a traffic unit. This
means that CU replacement with auto-upgrade will not work on
this node.
Note that this alarm might be seen in up to approximately 5
minutes after a 'SW not downloaded' alarm is cleared to inform
that SW packages are not yet distributed.
Possible reasons:
1. If parts of the master CU software were updated without an
enm-spec file there might be a mismatch between executing
and expected software resulting in this alarm. If so
perform a full upgrade to preferred enm-spec version.
2. More than one traffic unit might be needed to distribute
software, insert another traffic unit into the node main
subrack or if running CU-SFP as master CU, reconfigure the
'Supported replacement CUs' attribute to the control unit
type(s) appropriate for your system.
Context
- MIB
- LUM-SOFTWARE-MIB
- OID
.1.3.6.1.4.1.8708.2.28.2.8.7- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- softwareCuRep
- Siblings
- 7
Values & Constraints
Type Values
1 | ok |
2 | alarm |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| softwareCuRepAdminStatus The administrative state for the alarm.
down - No alarm will be rasied if SW packages are missing.
service - No alarm will be rasied if SW packages are missi… | scalar | LUM-TCBoardOrInterfaceAdminStatus | .1.3.6.1.4.1.8708.2.28.2.8.1 |
| softwareCuRepUnSaved If the configuration is saved or not. | scalar | Enumeration | .1.3.6.1.4.1.8708.2.28.2.8.2 |
| softwareCuRepSystemMode If dipswitch is changed or not. | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.28.2.8.3 |
| softwareCuRepRebootCu If the CU should be rebooted or not. | scalar | Enumeration | .1.3.6.1.4.1.8708.2.28.2.8.4 |
| softwareCuRepOkConfigure Configure an CU that has correct SW.
Run automatically when in CU replacement mode
when CU is an CU-SFP AND SW is correct.
Asks for the following:
Configuration not sav… | scalar | LUM-TCCommandString | .1.3.6.1.4.1.8708.2.28.2.8.5 |
| softwareCuRepSwPackagesMissing Software package file(s) are missing on master CU.
When replacing or introducing CU or TU units some software
packages needs to be downloaded to the master CU in order … | scalar | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.28.2.8.6 |
| softwareCuRepSupportedReplacements The types of control unit boards which should be supported as
replacements for the current main control unit.
The system will transfer the software packages for the boa… | scalar | Enumeration | .1.3.6.1.4.1.8708.2.28.2.8.8 |