mesErpHoldOffTime

LUM-MES-MIB · .1.3.6.1.4.1.8708.2.32.2.26.1.1.12

Object

column r/w Unsigned32
A hold-off timer coordinates timing of protection
switches between multiple layers. The timer gives
another protection layer the possibility to solve
the issue before performing the protection
switch. When a signal fail event occurs, this event
is not reported until the hold-off timer has elapsed.
              
The hold-off time is defined in steps of
100 milliseconds.
              
Note! A non-zero hold-off time will impact the
protection switch time performance.

Context

MIB
LUM-MES-MIB
OID
.1.3.6.1.4.1.8708.2.32.2.26.1.1.12
Type
column
Access
readwrite
Status
current
Parent
mesErpEntry
Table
mesErpTable
Siblings
48

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-10000

Related Objects

Sibling Objects