juniFrCircuitSentFECNs
Juniper-FRAME-RELAY-MIB ·
.1.3.6.1.4.1.4874.2.2.10.1.1.4.1.22
Object
column
SNMPv2-SMICounter32
Number of frames sent to the network indicating forward congestion since the virtual circuit was created. This occurs when the remote DTE sets the FECN flag, or when a switch in the network enqueues the frame to a trunk whose transmission queue is congested.
Context
- MIB
- Juniper-FRAME-RELAY-MIB
- OID
.1.3.6.1.4.1.4874.2.2.10.1.1.4.1.22- Type
- column
- Access
- readonly
- Status
- current
- Parent
- juniFrCircuitEntry
- Table
- juniFrCircuitTable
- Siblings
- 22
Syntax
SNMPv2-SMICounter32
- Source
- SNMPv2-SMICounter32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| juniFrCircuitIfIndex The ifIndex Value of the ifEntry this virtual circuit is layered onto. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.1 |
| juniFrCircuitCreationTime The value of sysUpTime when the virtual circuit was created, whether by
the Data Link Connection Management Interface or by a SetRequest. | column | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.10 |
| juniFrCircuitLastTimeChange The value of sysUpTime when last there was a change in the virtual
circuit state | column | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.11 |
| juniFrCircuitCommittedBurst This variable indicates the maximum amount of data, in bits, that the
network agrees to transfer under normal conditions, during the
measurement interval. A value of zero (the de… | column | Integer32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.12 |
| juniFrCircuitExcessBurst This variable indicates the maximum amount of uncommitted data bits
that the network will attempt to deliver over the measurement interval.
By default, if not confi… | column | Integer32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.13 |
| juniFrCircuitThroughput Throughput is the average number of 'Frame Relay Information Field'
bits transferred per second across a user network interface in one
direction, measured over the measurement int… | column | Integer32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.14 |
| juniFrCircuitMulticast This indicates whether this VC is used as a unicast VC (i.e. not
multicast) or the type of multicast service subscribed to. | column | Enumeration | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.15 |
| juniFrCircuitType Indication of whether the VC was manually created (static), or
dynamically created (dynamic) via the data link control management
interface. | column | Enumeration | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.16 |
| juniFrCircuitDiscards The number of inbound frames dropped because of format errors, or
because the VC is inactive. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.17 |
| juniFrCircuitReceivedDEs Number of frames received from the network indicating that they were
eligible for discard since the virtual circuit was created. This occurs
when the remote DTE sets the DE flag,… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.18 |
| juniFrCircuitSentDEs Number of frames sent to the network indicating that they were eligible
for discard since the virtual circuit was created. This occurs when the
local DTE sets the DE flag, indica… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.19 |
| juniFrCircuitDlci The Data Link Connection Identifier for this virtual circuit. | column | FRAME-RELAY-DTE-MIBDLCI | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.2 |
| juniFrCircuitLogicalIfIndex Normally the same value as frDlcmiIfIndex, but different when an
implementation associates a virtual ifEntry with a DLC or set of DLCs in
order to associate higher layer objects s… | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.20 |
| juniFrCircuitRowStatus This object is used to create a new row or modify or destroy an
existing row in the manner described in the definition of the RowStatus
textual convention. Writable objects in th… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.21 |
| juniFrCircuitSentBECNs Number of frames sent to the network indicating backward congestion
since the virtual circuit was created. This occurs when the remote DTE
sets the BECN flag, or when a switch in… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.23 |
| juniFrCircuitState Indicates whether the particular virtual circuit is operational. In
the absence of a Data Link Connection Management Interface, virtual
circuit entries (rows) may be created by s… | column | Enumeration | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.3 |
| juniFrCircuitReceivedFECNs Number of frames received from the network indicating forward
congestion since the virtual circuit was created. This occurs when the
remote DTE sets the FECN flag, or when a swit… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.4 |
| juniFrCircuitReceivedBECNs Number of frames received from the network indicating backward
congestion since the virtual circuit was created. This occurs when the
remote DTE sets the BECN flag, or when a swi… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.5 |
| juniFrCircuitSentFrames The number of frames sent from this virtual circuit since it was
created. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.6 |
| juniFrCircuitSentOctets The number of octets sent from this virtual circuit since it was
created. Octets counted are the full frame relay header and the
payload, but do not include the flag characters o… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.7 |
| juniFrCircuitReceivedFrames Number of frames received over this virtual circuit since it was
created. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.8 |
| juniFrCircuitReceivedOctets Number of octets received over this virtual circuit since it was
created. Octets counted include the full frame relay header, but do not
include the flag characters or the CRC. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.9 |