juniERXSysAdminTimingSource

Juniper-ERX-System-MIB · .1.3.6.1.4.1.4874.2.2.17.1.1.16

Object

scalar deprecated r/w JuniTimingSelector
The administrative timing source for the ERX system.  The ERX
periodically monitors the status of three timing sources, primary,
secondary and tertiary.  If the systems current timing source fails, the
system will automatically downgrade to the next timing source.  If the
system is configured to automatically upgrade
(juniERXSysTimingDisableAutoUpgrade is set to false(2)) the system will
switch back to the higher timing source when it becomes available.
          
A timing source failure can be detected by comparing the operational and
admin timing sources.  If they are not equal, the system has swapped
timing sources because the administratively set value is in the error
state.

Context

MIB
Juniper-ERX-System-MIB
OID
.1.3.6.1.4.1.4874.2.2.17.1.1.16
Type
scalar
Access
readwrite
Status
deprecated
Parent
juniERXSysGeneral
Siblings
24

Syntax

JuniTimingSelector
Source
JuniTimingSelector
Base type
Integer32

Values & Constraints

Type Constraints
range: 1..4

Related Objects

Sibling Objects