jnxPingCtlEgressStdDevThreshold

JUNIPER-PING-MIB · .1.3.6.1.4.1.2636.3.7.1.2.1.11

Object

column r/w microseconds Unsigned32
The maximum egress trip time standard deviation allowed over the
course of any test.  If the calculated standard deviation of the
egress trip time at the end of any test exceeds this threshold,
a jnxPingEgressStdDevThresholdExceeded trap will be sent.
This applies only if the probe type (pingCtlType) provides one way
delay measurements.  Currently jnxPingIcmpTimeStamp is the only
supported probe type with this property.

Context

MIB
JUNIPER-PING-MIB
OID
.1.3.6.1.4.1.2636.3.7.1.2.1.11
Type
column
Access
readwrite
Status
current
Units
microseconds
Parent
jnxPingCtlEntry
Table
jnxPingCtlTable
Siblings
22

Syntax

microseconds Unsigned32

Values & Constraints

Object Constraints
range: 0-60000000

Related Objects