vdsl2ChConfProfMinProtectionDs

HUAWEI-VDSL2-LINE-MIB · .1.3.6.1.4.1.2011.6.115.1.5.2.1.1.12

Object

column r/w symbols HUAWEI-VDSL2-LINE-TC-MIBVdsl2SymbolProtectionDs
If retransmission is not used in downstream direction,this parameter
is minimum impulse noise protection for the bearer channel on downstream
direction. The minimum impulse noise protection for the bearer channel,
expressed in symbols.  The parameter can take the following
values: noProtection (i.e., INP not required), halfSymbol
(i.e., INP length is 1/2 symbol) and 1-16 symbols in steps
of 1 symbol.
Unit: symbols

Context

MIB
HUAWEI-VDSL2-LINE-MIB
OID
.1.3.6.1.4.1.2011.6.115.1.5.2.1.1.12
Type
column
Access
readwrite
Status
current
Units
symbols
Parent
vdsl2ChConfProfileEntry
Table
vdsl2ChConfProfileTable
Siblings
55

Syntax

symbols HUAWEI-VDSL2-LINE-TC-MIBVdsl2SymbolProtectionDs
Source
HUAWEI-VDSL2-LINE-TC-MIBVdsl2SymbolProtectionDs
Base type
Enumeration

Values & Constraints

Type Values
1noProtection
2halfSymbol
3singleSymbol
4twoSymbols
5threeSymbols
6fourSymbols
7fiveSymbols
8sixSymbols
9sevenSymbols
10eightSymbols
11nineSymbols
12tenSymbols
13elevenSymbols
14twelveSymbols
15thirteenSymbols
16fourteenSymbols
17fifteenSymbols
18sixteenSymbols

Related Objects

Sibling Objects