hwPowerRemoteLineState
HUAWEI-POWER-MIB ·
.1.3.6.1.4.1.2011.6.2.1.7.1.9
Object
column
r/w
Bits
State of line U1. Options: 1. u1state(0) - indicates the power remote line state is u1 state 2. u2state(1) - indicates the power remote line state is u2 state 3. u3state(2) - indicates the power remote line state is u3 state 4. u4state(3) - indicates the power remote line state is u4 state 5. a1state(4) - indicates the power remote line state is a1 state 6. a2state(5) - indicates the power remote line state is a2 state 7. a3state(6) - indicates the power remote line state is a3 state 8. a4state(7) - indicates the power remote line state is a4 state
Context
- MIB
- HUAWEI-POWER-MIB
- OID
.1.3.6.1.4.1.2011.6.2.1.7.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwRemoteProvidePowerInfoEntry
- Table
- hwRemoteProvidePowerInfoTable
- Siblings
- 9
Syntax
Bits
Values & Constraints
Enumerated Values
0 | u1state |
1 | u2state |
2 | u3state |
3 | u4state |
4 | a1state |
5 | a2state |
6 | a3state |
7 | a4state |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwPowerCentralState State of the central module.
Options:
1. normal(1) - indicates the normal state
2. temOver(2) - indicates the over-temperature | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.1 |
| hwPowerCentralLoadState state of central load.
Options:
1. normal(1) - indicates the normal state
2. overload(2) - indicates overload
3. nonload(3) - indicates non-load | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.10 |
| hwPowerCentralDCInPutState State of central module DC input:
Options:
1.normal(1) - indicates the normal state
2.lack(2) - indicates the voltage underflow
3.over(3) - indicates the voltage overflow | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.2 |
| hwPowerCentralDCOutputState State of central module DC output.
Options:
1. normal(1) - indicates the normal state
2. volLack(2) - indicates the voltage underflow
3. volOver(3) - indicates… | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.3 |
| hwPowerCentralDCOutputMode Mode of central module DC output.
Options:
1. highVolMode(1) - indicates the high voltage output mode
2. lowVolMode(2) - indicates the low voltage output mode | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.4 |
| hwPowerRemoteCommState Remote power module communications state.
Options:
1. normal(1) - indicates the normal state
2. revfault(2) - indicates the receiving of fault
3. sendfault(3) - indicates… | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.5 |
| hwPowerRemoteDCInputState State of remote module DC input.
Options:
1. normal(1) - indicates the normal state
2. lack(2) - indicates that the voltage is underflow | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.6 |
| hwPowerRemoteLineCurState state of line between central and remote module.
Options:
1.normal(1) - indicates the normal state
2.cablejoining(2) - indicates the cable joining
3.curLeakage(3) - indica… | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.7 |
| hwPowerRemotePowerState state of remote UA60 power.
Options:
1. normal(1) - indicates the normal state
2. fault(2) - indicates the faulty state | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.8 |