hwPowerRemoteLineCurState
HUAWEI-POWER-MIB ·
.1.3.6.1.4.1.2011.6.2.1.7.1.7
Object
column
r/w
Enumeration
state of line between central and remote module. Options: 1.normal(1) - indicates the normal state 2.cablejoining(2) - indicates the cable joining 3.curLeakage(3) - indicates the cur Leakage 4.curOver(4) - indicates the cur Over
Context
- MIB
- HUAWEI-POWER-MIB
- OID
.1.3.6.1.4.1.2011.6.2.1.7.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwRemoteProvidePowerInfoEntry
- Table
- hwRemoteProvidePowerInfoTable
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | normal |
2 | cablejoining |
3 | curLeakage |
4 | curOver |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwPowerCentralState State of the central module.
Options:
1. normal(1) - indicates the normal state
2. temOver(2) - indicates the over-temperature | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.1 |
| hwPowerCentralLoadState state of central load.
Options:
1. normal(1) - indicates the normal state
2. overload(2) - indicates overload
3. nonload(3) - indicates non-load | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.10 |
| hwPowerCentralDCInPutState State of central module DC input:
Options:
1.normal(1) - indicates the normal state
2.lack(2) - indicates the voltage underflow
3.over(3) - indicates the voltage overflow | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.2 |
| hwPowerCentralDCOutputState State of central module DC output.
Options:
1. normal(1) - indicates the normal state
2. volLack(2) - indicates the voltage underflow
3. volOver(3) - indicates… | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.3 |
| hwPowerCentralDCOutputMode Mode of central module DC output.
Options:
1. highVolMode(1) - indicates the high voltage output mode
2. lowVolMode(2) - indicates the low voltage output mode | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.4 |
| hwPowerRemoteCommState Remote power module communications state.
Options:
1. normal(1) - indicates the normal state
2. revfault(2) - indicates the receiving of fault
3. sendfault(3) - indicates… | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.5 |
| hwPowerRemoteDCInputState State of remote module DC input.
Options:
1. normal(1) - indicates the normal state
2. lack(2) - indicates that the voltage is underflow | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.6 |
| hwPowerRemotePowerState state of remote UA60 power.
Options:
1. normal(1) - indicates the normal state
2. fault(2) - indicates the faulty state | column | Enumeration | .1.3.6.1.4.1.2011.6.2.1.7.1.8 |
| hwPowerRemoteLineState State of line U1.
Options:
1. u1state(0) - indicates the power remote line state is u1 state
2. u2state(1) - indicates the power remote line state is u2 state
3. u3state(2) - indi… | column | Bits | .1.3.6.1.4.1.2011.6.2.1.7.1.9 |