hwRsBaudrate
HUAWEI-PORT-MIB ·
.1.3.6.1.4.1.2011.5.25.157.1.23.3.1.6
Object
column
r/w
Integer32
This object indicates the baud rate of a serial interface. The value can be : 0: 600bit/s, 1: 1200bit/s, 2: 2400bit/s, 3: 4800bit/s, 4: 9600bit/s, 5: 19200bit/s, 6: 38400bit/s, 7: 48000bit/s, 8~38: N*64Kbit/s N<=31. The default value is 9600 bit/s in asynchronous transfer mode and 64 kbit/s in synchronous transfer mode.
Context
- MIB
- HUAWEI-PORT-MIB
- OID
.1.3.6.1.4.1.2011.5.25.157.1.23.3.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwRsEntry
- Table
- hwRsTable
- Siblings
- 12
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-38
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwRsIfIndex The value of this object identifies the index of a serial interface on a device. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.1 |
| hwRsStopbits This object indicates the number of stop bits contained in a serial interface's asynchronous frame.
This object can be configured in asynchronous clock mode.
The value can be 1-b… | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.10 |
| hwRsDatabits This object indicates the number of data bits contained in a serial interface's asynchronous frame.
This object can be configured in asynchronous clock mode.
The value ranges from… | column | Integer32 | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.11 |
| hwRsMuxProtocol This object indicates the type of a serial interface's sub-rate multiplexing protocol.
This object can be configured in asynchronous clock mode.
The value can be sbit-loop,sbit=0… | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.12 |
| hwRsX50PhaseMode This object indicates the envelope phase mode multiplexed by a serial interface's x.50 sub-rate.
The value can be sequence or interval. The default value is sequence. | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.13 |
| hwRsPortMode This object indicates the type of a serial interface.
The value can be rs-232,rs-485,rs-422,,v.24,x.21 or v.35.
For NED1MPAA/CR23MPAA PICs:
Ports 0 and 2 work in rs-232 mode. Th… | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.2 |
| hwRsWorkMode This object indicates the mode in which a serial interface works.
The value can be dce or dte. The default value is dce. | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.3 |
| hwRsPhysicalMode This object indicates the mode in which a serial interface transmits signals.
The value can be async or sync. The default value is async. | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.4 |
| hwRsClockSource This object indicates the clock source mode of a serial interface.
The value can be internal,external or slave. The default value is internal. | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.5 |
| hwRsClockSendMode This object indicates the mode in which clock signals transmitted by a serial interface are sampled.
This mode can be configured in synchronous clock mode.
The value can be inpha… | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.7 |
| hwRsClockReceiveMode This object indicates the mode in which clock signals received by a serial interface are sampled.
This mode can be configured in synchronous clock mode.
The value can be inphase … | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.8 |
| hwRsParity This object indicates the parity check mode of a serial interface's asynchronous frames.
This mode can be configured in asynchronous clock mode.
The value can be none,even or odd… | column | Enumeration | .1.3.6.1.4.1.2011.5.25.157.1.23.3.1.9 |