hwPotsLooplineThresholdTable
HUAWEI-NTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.2.1.1.21
Object
node
No description available.
Context
- MIB
- HUAWEI-NTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.2.1.1.21- Type
- node
- Parent
- hwNTestMIBObjects
- Siblings
- 35
- Children
- 49
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwPstnCircuitTestOprTable Operation table for the PSTN subscriber circuit test:
It realizes the function of the circuit test for analog subscribers in the system. The circuit test helps you to ensure that … | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.1 |
| hwPstnCallerEmulateOprTable Operation table for the PSTN call emulation test (calling party):
It realizes the function of the call emulation test (caller dial) in the system. This test helps check whether a … | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.10 |
| hwPstnCalledEmulateOprTable The operation table of the caller test of the PSTN call emulation test. It is used to realize the caller
test of the PSTN call emulation test, which is used to test whether a use… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.11 |
| hwPstnTelephoneTestOprTable The operation table of the called test of the PSTN call emulation test. It is used to realize the called
test of the PSTN call emulation test, which is used to test whether a use… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.12 |
| hwIsdnUserDiagnoseTestOprTable Operation table for the diagnosis test on the ISDN subscribers:
It realizes the diagnosis test on the ISDN subscribers in the system. This test helps check the status and performa… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.13 |
| hwPstnSignalToneTestOprTable Operation table for the PSTN signal tone test:
It realizes the function of the PSTN signal tone test in the system. This test helps check whether the dial tone and the dial tone d… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.14 |
| hwIsdnMeterTestOprTable Operation table for the ISDN meter test:
It realizes the function of the ISDN meter test in the system. The test board provides, through the meter test function, the interface co… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.15 |
| hwTestBusTestOprTable Test on the circuit/loop-line test bus:
It realizes the function of the test on the circuit/loop-line test bus. This test helps check whether the circuit/loop-line test bus is nor… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.16 |
| hwFrameLooplineAdjustOprTable The loop line test for get check value.
The index of this table is hwFrameIndex | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.17 |
| hwFrameLooplineAdjustTable GET table for the shelf calibration values:
It realizes the function of obtaining the shelf calibration values.
The index of this table is hwFrameIndex. | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.18 |
| hwQosTestIndexNext This object contains an appropriate value to
be used for hwQosTestIndex when creating
entries in the hwQosTestTable. The value
0 indicates that no unassigned entries are
availabl… | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.19 |
| hwIsdnUserInTestOprTable Describes the Operation table for the ISDN subscriber circuit test:
It realizes the function of the circuit test for ISDN subscribers in the system. In the circuit test, th… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.2 |
| hwQosTestOprTable Table for the QoS test.
The index of this table is hwQosTestIndex. | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.20 |
| hwResistEmendationThresholdTable | node | - | .1.3.6.1.4.1.2011.6.21.2.1.1.22 |
| hwTestTimeLimitThresholdTable | node | - | .1.3.6.1.4.1.2011.6.21.2.1.1.23 |
| hwSDLMeterTestOprTable Operation table for the SDL meter test:
It realizes the function of the SDL meter test in the system. The test board provides, through the meter test function, the interface conn… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.24 |
| hwSDLDMMTestOprTable Operation table for the SDL DMM test:
It realizes the function of the SDL DMM test in the system.
In the test, the voltage, resistance, and capacitance of the
loop line are tes… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.25 |
| hwLoopLineToneOprTable Operation table for the loop-line tone test:
It realizes the function of the test on the circuit and loop-line signals.
The index of this table is ifIndex. | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.26 |
| hwPotsSelfCircuitTestOprTable Operation table for the PSTN subscriber circuit test.
The index of this table is ifIndex. | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.27 |
| hwPstnCallTestOprTable | node | - | .1.3.6.1.4.1.2011.6.21.2.1.1.28 |
| hwPstnCallTestResultTable Table for the result of the query test
The index of this table is hwPstnCallTestResultIndex | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.29 |
| hwIsdnUserOutTestOprTable Operation table for the ISDN subscriber loop-line test:
It realizes the function of the loop-line test for ISDN subscribers in the system. In the loop-line test, the Activate NT1,… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.3 |
| hw112UserInDialTestOprTable This table is used to check whether a subscriber telephone can work in the normal state. The method is that the operator emulates a tested port to make calls.
The index of this ta… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.30 |
| hwISDNDiagnoseTestTable User fault test table.
The index of this table is ifIndex. | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.31 |
| hwPstnCallEmulateOprTable Operation table for the PSTN call emulation test (called party). It realizes the
function of the PSTN call emulation test (called party). This test helps check whether a subscrib… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.32 |
| hwPstnLoopTestOprTable Loop test table
The index of this table is hwPstnLoopTestSerialNo | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.33 |
| hwPstnCallEmulateConfigTable | node | - | .1.3.6.1.4.1.2011.6.21.2.1.1.34 |
| hwLineTestParaTable pots test para config table
The index of this table is hwLineTestParaFrameIndex and hwLineTestParaSlotIndex | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.35 |
| hwMonitorTestOprTable monitor test table
The index of this table is ifIndex | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.36 |
| hwIsdnUserOutLineTestOprTable Operation table for the ISDN subscriber loop-line test.
It realizes the function of the loop-line test for ISDN subscribers in the system. In the loop-line test, the voltage, resi… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.4 |
| hwIsdnPortStateSwitchTestOprTable Operation table for the test on ISDN port status switching:
It realizes the function of the test on ISDN port status switching in the system. In the test, the status of a port is … | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.5 |
| hw112UserRingTestOprTable Ringing test on the 112 analog subscriber phones:
It realizes the function of the ringing test on the phones of subscribers in the system. This test helps check whether a subscrib… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.6 |
| hw112UserDialTestOprTable Operation table for the test on the DTMF or pulse feature of the 112 analog subscriber phones:
It realizes the test on the DTMF or pulse feature of the subscriber phones in the sy… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.7 |
| hw112UserHowlerTestOprrTable Operation table for the howler tone test on 112 analog subscriber phones:
It realizes the function of the howler tone test on the subscriber phones in the system. This test helps … | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.8 |
| hw112IsdnDiagnoseTestOprTable Operation table for the diagnosis test on the 112 ISDN subscribers:
It realizes the function of the diagnosis test on the 112 ISDN subscribers in the system. Its test items are th… | table | - | .1.3.6.1.4.1.2011.6.21.2.1.1.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwTouchThePowerVolThreshold Hazardous AC voltage level
Unit: V
Default: 50 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.1 |
| hwABPoorLineInsulationMaxThreshold A-B insulation difference: A-B resistance upper limit.
Unit: ohm
Default: 20000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.10 |
| hwLeakageGroundCapThreshold Leakage: ground capacitance threshold.
Unit: nF
Default: 700 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.11 |
| hwNormalGroundCap1Threshold Normal: ground capacitance threshold 1.
Unit: nF
Default: 200 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.12 |
| hwNormalGroundCap2Threshold Normal: ground capacitance threshold 2.
Unit: nF
Default: 350 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.13 |
| hwNormalGroundCap3Threshold Normal: ground capacitance threshold 3.
Unit: nF
Default: 50 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.14 |
| hwAbnormalImpedanceABhreshold On hook: lower limit of the A-B abnormal impedance (ohm)
Default: 10000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.15 |
| hwAbnormalACElectricCurrentThreshold Abnormal AC current: threshold of the abnormal AC current (mA)
Default: 1000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.16 |
| hwAbnormalDCElectricCurrentThreshold Abnormal DC current: threshold of the abnormal DC current (mA)
Default: 1000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.17 |
| hwAbnormalACVoltageThreshold Abnormal AC voltage: threshold 1 of the abnormal AC voltage (V)
Default: 10 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.18 |
| hwAbnormalDCVoltage1Threshold Abnormal DC voltage: threshold 1 of the abnormal DC voltage (V)
Default: 10 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.19 |
| hwLoopLineMixedVolThreshold Foreign EMF DC voltage level.
Unit: V
Default: 10 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.2 |
| hwAbnormalDCVoltage2Threshold Abnormal DC voltage: threshold 2 of the abnormal DC voltage (V)
Default: 55 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.20 |
| hwAbnormalOnhookLoopLineElectricCurrentMaxThreshold Abnormal on-hook loop current: upper limit of the abnormal on-hook loop current (mA)
Default: 30 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.21 |
| hwAbnormalOnhookLoopResistanceThreshold Abnormal on-hook loop resistance: threshold of the abnormal on-hook loop resistance (ohm)
Default: 250000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.22 |
| hwAbnormalOffhookLoopResistanceThreshold Abnormal off-hook loop resistance: threshold of the abnormal off-hook loop resistance (ohm)
Default: 250000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.23 |
| hwAbnormalGroundInsulationResistance1Threshold Abnormal ground insulation resistance: threshold 1 of the abnormal ground insulation resistance (ohm)
Default: 5000000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.24 |
| hwAbnormalGroundPoorLineInsulation1Threshold Abnormal ground insulation difference: threshold 1 of the abnormal ground insulation difference (ohm)
Default: 250000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.25 |
| hwAbnormalGroundCapacitanceThreshold Abnormal ground capacitance: threshold of the abnormal ground capacitance (nF)
Default: 200 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.26 |
| hwAbnormalCapacitanceABMinThreshold Abnormal: lower limit of the abnormal A-B capacitance (nF)
Default: 0 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.27 |
| hwAbnormalCapacitanceABMaxThreshold Abnormal: upper limit of the abnormal A-B capacitance (nF)
Default: 2000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.28 |
| hwAbnormalNoiseThreshold Abnormal noise: threshold 1 of the abnormal noise (dBm)
Default: 65 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.29 |
| hwLoopLineGroundingVolThreshold Loop line grounding: Ground resistance threshold.
Unit: ohm
Default: 20000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.3 |
| hwLoopParamsCab Cable characteristic capacitance per unit length between tip and ring
Unit : nf per km
Range: 0-100
Default: 19 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.30 |
| hwLoopParamsCagbg Cable characteristic capacitance per unit length between tip and GND and ring and GND
Unit : nf per km
Range: 0-100
Default: 62 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.31 |
| hwLoopParamsRab Cable loop DC resistance per unit length (sum of both wires)
Unit : ohm per km
Range: 50-600
Default: 295 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.32 |
| hwLrcThMaxsc maximum resistance for tip or ring short-circuit to GND
Unit : ohm
Range: 0-1000000
Default: 2000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.33 |
| hwLrcThMaxLg maximum resistance for tip or ring leakage to GND
Unit : ohm
Range: 0-1000000
Default: 200000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.34 |
| hwHdcvL Hazardous DC voltage level
Unit : mV
Range: 0-500000
Default: 80000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.35 |
| hwFacvL Foreign EMF AC voltage level
Unit : mVrms
Range: 0-200000
Default: 10000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.36 |
| hwMinetsiSc minimum ETSI signature capacitance
Unit : nf
Range: 100-500
Default: 350 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.37 |
| hwMaxetsiSc maximum ETSI signature capacitance
Unit : nf
Range: 500-1000
Default: 520 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.38 |
| hwMinetsiPr minimum PPA resisitance
Unit : ohm
Range: 200000-400000
Default: 350000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.39 |
| hwOffHookABMinThreshold Off-hook: A-B resistance lower limit.
Unit: ohm
Default: 3000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.4 |
| hwMaxetsiPr maximum PPA resistance
Unit : ohm
Range: 400000-700000
Default: 520000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.40 |
| hwMinZenerZv minimum voltage to conduct current through the zener diode
Unit : mV
Range: 500-10000
Default: 1000
Step: 100 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.41 |
| hwMaxRcrTr maximum RC network resistance between tip and ring
Unit : ohm
Range: 0-10000000
Default: 1000000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.42 |
| hwMinRcrTr minimum RC network resistance between tip and ring
Unit : ohm
Range: 0-10000000
Default: 10000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.43 |
| hwCpeCab minimum RC network capacitance between tip and ring
Unit : nf
Range: 0-5000
Default: 350 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.44 |
| hwMinhrTr minimum high resistance between tip and ring
Unit : ohm
Range: 0-10000000
Default: 1000000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.45 |
| hwFvcLim minimum foreign voltage
Unit : mV
Range: 0-50000
Default: 8000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.46 |
| hwMinOffhookR minimum equivalent resistance when off-hook on zero kilometres
Unit : ohm
Range: 0-1000
Default: 200 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.47 |
| hwLepPar line length windage for open wire failure
Unit : m
Range: 0-500
Default: 200 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.48 |
| hwLooplineThresholdOprType Operation type.
Options:
1. restore(1) -restore default threshold value
2. invalid(-1) -invalid | scalar | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.21.49 |
| hwOffHookABMaxThreshold Off-hook: A-B resistance upper limit.
Unit: ohm
Default: 100000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.5 |
| hwOffHookLoopMinThreshold Off-hook: loop resistance lower limit.
Unit: ohm
Initial value: 100 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.6 |
| hwOffHookLoopMaxThreshold Off-hook: loop resistance upper limit.
Unit: ohm
Initial value: 3000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.7 |
| hwLoopLineMixedABThreshold Loop line mixed with others: A-B resistance threshold.
Unit: ohm
Initial value: 2000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.8 |
| hwABPoorLineInsulationMinThreshold A-B insulation difference: A-B resistance lower limit.
Unit: ohm
Initial value: 2000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.9 |