hwLoopLineMixedABThreshold
HUAWEI-NTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.2.1.1.21.8
Object
scalar
r/w
Integer32
Loop line mixed with others: A-B resistance threshold. Unit: ohm Initial value: 2000
Context
- MIB
- HUAWEI-NTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.2.1.1.21.8- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hwPotsLooplineThresholdTable
- Siblings
- 48
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwTouchThePowerVolThreshold Hazardous AC voltage level
Unit: V
Default: 50 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.1 |
| hwABPoorLineInsulationMaxThreshold A-B insulation difference: A-B resistance upper limit.
Unit: ohm
Default: 20000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.10 |
| hwLeakageGroundCapThreshold Leakage: ground capacitance threshold.
Unit: nF
Default: 700 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.11 |
| hwNormalGroundCap1Threshold Normal: ground capacitance threshold 1.
Unit: nF
Default: 200 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.12 |
| hwNormalGroundCap2Threshold Normal: ground capacitance threshold 2.
Unit: nF
Default: 350 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.13 |
| hwNormalGroundCap3Threshold Normal: ground capacitance threshold 3.
Unit: nF
Default: 50 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.14 |
| hwAbnormalImpedanceABhreshold On hook: lower limit of the A-B abnormal impedance (ohm)
Default: 10000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.15 |
| hwAbnormalACElectricCurrentThreshold Abnormal AC current: threshold of the abnormal AC current (mA)
Default: 1000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.16 |
| hwAbnormalDCElectricCurrentThreshold Abnormal DC current: threshold of the abnormal DC current (mA)
Default: 1000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.17 |
| hwAbnormalACVoltageThreshold Abnormal AC voltage: threshold 1 of the abnormal AC voltage (V)
Default: 10 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.18 |
| hwAbnormalDCVoltage1Threshold Abnormal DC voltage: threshold 1 of the abnormal DC voltage (V)
Default: 10 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.19 |
| hwLoopLineMixedVolThreshold Foreign EMF DC voltage level.
Unit: V
Default: 10 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.2 |
| hwAbnormalDCVoltage2Threshold Abnormal DC voltage: threshold 2 of the abnormal DC voltage (V)
Default: 55 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.20 |
| hwAbnormalOnhookLoopLineElectricCurrentMaxThreshold Abnormal on-hook loop current: upper limit of the abnormal on-hook loop current (mA)
Default: 30 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.21 |
| hwAbnormalOnhookLoopResistanceThreshold Abnormal on-hook loop resistance: threshold of the abnormal on-hook loop resistance (ohm)
Default: 250000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.22 |
| hwAbnormalOffhookLoopResistanceThreshold Abnormal off-hook loop resistance: threshold of the abnormal off-hook loop resistance (ohm)
Default: 250000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.23 |
| hwAbnormalGroundInsulationResistance1Threshold Abnormal ground insulation resistance: threshold 1 of the abnormal ground insulation resistance (ohm)
Default: 5000000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.24 |
| hwAbnormalGroundPoorLineInsulation1Threshold Abnormal ground insulation difference: threshold 1 of the abnormal ground insulation difference (ohm)
Default: 250000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.25 |
| hwAbnormalGroundCapacitanceThreshold Abnormal ground capacitance: threshold of the abnormal ground capacitance (nF)
Default: 200 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.26 |
| hwAbnormalCapacitanceABMinThreshold Abnormal: lower limit of the abnormal A-B capacitance (nF)
Default: 0 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.27 |
| hwAbnormalCapacitanceABMaxThreshold Abnormal: upper limit of the abnormal A-B capacitance (nF)
Default: 2000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.28 |
| hwAbnormalNoiseThreshold Abnormal noise: threshold 1 of the abnormal noise (dBm)
Default: 65 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.29 |
| hwLoopLineGroundingVolThreshold Loop line grounding: Ground resistance threshold.
Unit: ohm
Default: 20000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.3 |
| hwLoopParamsCab Cable characteristic capacitance per unit length between tip and ring
Unit : nf per km
Range: 0-100
Default: 19 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.30 |
| hwLoopParamsCagbg Cable characteristic capacitance per unit length between tip and GND and ring and GND
Unit : nf per km
Range: 0-100
Default: 62 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.31 |
| hwLoopParamsRab Cable loop DC resistance per unit length (sum of both wires)
Unit : ohm per km
Range: 50-600
Default: 295 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.32 |
| hwLrcThMaxsc maximum resistance for tip or ring short-circuit to GND
Unit : ohm
Range: 0-1000000
Default: 2000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.33 |
| hwLrcThMaxLg maximum resistance for tip or ring leakage to GND
Unit : ohm
Range: 0-1000000
Default: 200000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.34 |
| hwHdcvL Hazardous DC voltage level
Unit : mV
Range: 0-500000
Default: 80000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.35 |
| hwFacvL Foreign EMF AC voltage level
Unit : mVrms
Range: 0-200000
Default: 10000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.36 |
| hwMinetsiSc minimum ETSI signature capacitance
Unit : nf
Range: 100-500
Default: 350 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.37 |
| hwMaxetsiSc maximum ETSI signature capacitance
Unit : nf
Range: 500-1000
Default: 520 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.38 |
| hwMinetsiPr minimum PPA resisitance
Unit : ohm
Range: 200000-400000
Default: 350000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.39 |
| hwOffHookABMinThreshold Off-hook: A-B resistance lower limit.
Unit: ohm
Default: 3000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.4 |
| hwMaxetsiPr maximum PPA resistance
Unit : ohm
Range: 400000-700000
Default: 520000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.40 |
| hwMinZenerZv minimum voltage to conduct current through the zener diode
Unit : mV
Range: 500-10000
Default: 1000
Step: 100 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.41 |
| hwMaxRcrTr maximum RC network resistance between tip and ring
Unit : ohm
Range: 0-10000000
Default: 1000000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.42 |
| hwMinRcrTr minimum RC network resistance between tip and ring
Unit : ohm
Range: 0-10000000
Default: 10000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.43 |
| hwCpeCab minimum RC network capacitance between tip and ring
Unit : nf
Range: 0-5000
Default: 350 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.44 |
| hwMinhrTr minimum high resistance between tip and ring
Unit : ohm
Range: 0-10000000
Default: 1000000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.45 |
| hwFvcLim minimum foreign voltage
Unit : mV
Range: 0-50000
Default: 8000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.46 |
| hwMinOffhookR minimum equivalent resistance when off-hook on zero kilometres
Unit : ohm
Range: 0-1000
Default: 200 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.47 |
| hwLepPar line length windage for open wire failure
Unit : m
Range: 0-500
Default: 200 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.48 |
| hwLooplineThresholdOprType Operation type.
Options:
1. restore(1) -restore default threshold value
2. invalid(-1) -invalid | scalar | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.21.49 |
| hwOffHookABMaxThreshold Off-hook: A-B resistance upper limit.
Unit: ohm
Default: 100000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.5 |
| hwOffHookLoopMinThreshold Off-hook: loop resistance lower limit.
Unit: ohm
Initial value: 100 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.6 |
| hwOffHookLoopMaxThreshold Off-hook: loop resistance upper limit.
Unit: ohm
Initial value: 3000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.7 |
| hwABPoorLineInsulationMinThreshold A-B insulation difference: A-B resistance lower limit.
Unit: ohm
Initial value: 2000 | scalar | Integer32 | .1.3.6.1.4.1.2011.6.21.2.1.1.21.9 |