hwIsdnUserOutLineTestConclusion
HUAWEI-NTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.2.1.1.4.1.7
Object
column
SNMPv2-SMIInteger32
Conclusion Range:1-89 (Enumerated type. 1: Normal 2: Contact with the power line 3: A line mixed with others 4: B line mixed with others 5: Mixed with others (two lines) 6: A line grounding 7: B line grounding 8: AB grounding 9: Self-mixed (small resistance, self-mixed) 10: A-B poor insulation 11: A-ground leakage 12: B-ground leakage 13: AB ground leakage 14: A-B leakage 15: NT1 not connected 16: not on-hook 17: unknown 18: self-Mixed(inMDF) 19: self-Mixed(outMDF) 20: cutLine(inMDF) 21: cutLine(outMDF) 22: A-B voltage abnormal 23:lines voltage abnormal 24:lines resistance abnormal 25: A-B resistance abnormal 26: self-mixed (small resistance, self-mixed) or not on-hook 27:lines abnormal 30: DC voltage(Power feed) 31: AC voltage(Ringing) 32: DC voltage(Offhook) 33: DC voltage 34: AC voltage 60: A->ground AC voltage abnormal 61: B->ground AC voltage abnormal 62: AB-ground AC voltage abnormal 63: AB->ground DC voltage abnormal 64: A->ground DC voltage abnormal 65: B->ground DC voltage abnormal 66: A-B DC voltage abnormal 67: A->ground insulation resistance abnormal 68: B->ground insulation resistance abnormal 69: AB->ground insulation resistance abnormal 70: A->ground poor insulation 71: B->ground poor insulation 72: AB->ground poor insulation 73: A->ground impedance abnormal 74: B->ground impedance abnormal 75: A->B impedance abnormal 76: B->A impedance abnormal 77: A->ground AC current abnormal 78: B->ground AC current abnormal 79: A-B AC current abnormal 80: A->ground DC current abnormal 81: B->ground DC current abnormal 82: A-B DC current abnormal 83: loop current abnormal 84: loop resistance abnormal 85: AB->ground capacitance abnormal 86: A->ground capacitance abnomal 87: B->ground capacitacne abnormal 88: A-B capacitance abnomal 89: noise abnomal
Context
- MIB
- HUAWEI-NTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.2.1.1.4.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- hwIsdnUserOutLineTestOprEntry
- Table
- hwIsdnUserOutLineTestOprTable
- Siblings
- 34
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwIsdnUserOutLineTestOprType Describes the Operation type.
Options:
1. stop(1) -stop the test
2. start(2) -start the test | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.1 |
| hwIsdnUserOutLineTestACAB A->B AC voltage.
Unit: millivolt, ab. mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.10 |
| hwIsdnUserOutLineTestDCAG A->ground DC voltage.
Unit: millivolt, ab. mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.11 |
| hwIsdnUserOutLineTestDCBG B->ground DC voltage.
Unit: millivolt, ab. mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.12 |
| hwIsdnUserOutLineTestDCAB A->B DC voltage.
Unit: millivolt, ab. mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.13 |
| hwIsdnUserOutLineTestRAG A->ground insulation resistance.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.14 |
| hwIsdnUserOutLineTestRBG B->ground insulation resistance.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.15 |
| hwIsdnUserOutLineTestRAB A->B insulation resistance.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.16 |
| hwIsdnUserOutLineTestCapAG A->ground capacitance.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.17 |
| hwIsdnUserOutLineTestCapBG B->ground capacitance.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.18 |
| hwIsdnUserOutLineTestCapAB A->B capacitance.
Unit: nF | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.19 |
| hwIsdnUserOutLineTestVoltage ISDN loop line test-Voltage.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.2 |
| hwIsdnUserOutLineTestImpedance Loop-Line Test-Impedance.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.20 |
| hwIsdnUserOutLineTestImpedanceAB A->B impedance.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.21 |
| hwIsdnUserOutLineTestImpedanceBA B->A impedance.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.22 |
| hwIsdnUserOutLineTestImpedanceAG A->ground impedance.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.23 |
| hwIsdnUserOutLineTestImpedanceBG B->ground impedance.
Unit: ohm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.24 |
| hwIsdnUserOutLineTestCurrent Loop line test-Current.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.25 |
| hwIsdnUserOutLineTestACCurrentAG A->ground AC current
Unit: mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.26 |
| hwIsdnUserOutLineTestACCurrentBG B->ground AC current.
Unit: mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.27 |
| hwIsdnUserOutLineTestACCurrentAB AB AC current.
Unit: mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.28 |
| hwIsdnUserOutLineTestDCCurrentAG A->ground DC current.
Unit: mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.29 |
| hwIsdnUserOutLineTestResistance ISDN loop line test-Resistance.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.3 |
| hwIsdnUserOutLineTestDCCurrentBG B->ground DC current.
Unit: mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.30 |
| hwIsdnUserOutLineTestDCCurrentAB AB DC current.
Unit: mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.31 |
| hwIsdnUserOutLineTestLoopCurrent Loop-Line Test-Loop Current.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.32 |
| hwIsdnUserOutLineTestLC Loop Current.
Unit: mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.33 |
| hwIsdnUserOutLineTestNoise Loop-Line Test-Noise .
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.34 |
| hwIsdnUserOutLineTestN Noise.
Unit: dBm | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.35 |
| hwIsdnUserOutLineTestCapacitance ISDN loop line test-Capacitance.
Options:
1. notest(1) -no test is applied
2. test(2) -a test is applied | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.4 |
| hwIsdnUserOutLineTestBusyProcFlag Busy control flag .
Options:
1. busyNoTest(1) -indicates no test when busy
2. busyTest(2) -indicates remedy test when busy | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.5 |
| hwIsdnUserOutLineTestStatus Test status.
Options:
1. normal(1) -indicates normal
2. abnormal(2) -indicates abnormal
3. portbusy(3) -indicates busy port
4. outoftim… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.6 |
| hwIsdnUserOutLineTestACAG A->ground AC voltage.
Unit: millivolt, ab. mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.8 |
| hwIsdnUserOutLineTestACBG B->ground AC voltage.
Unit: millivolt, ab. mV | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.2.1.1.4.1.9 |