hwGBondGroupProfMinProtectionDs
HUAWEI-GBOND-MIB ·
.1.3.6.1.4.1.2011.6.137.6.1.5
Object
column
r/w
symbols GBondSymbolProtection
This parameter is minimum impulse noise protection for the bearer channel in the downstream direction, expressed in symbols. The parameter can take the following values: noProtection (i.e., INP not required), halfSymbol(i.e., INP length is 1/2 symbol) and 1-16 symbols in steps of 1 symbol.
Context
- MIB
- HUAWEI-GBOND-MIB
- OID
.1.3.6.1.4.1.2011.6.137.6.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Units
- symbols
- Parent
- hwGBondGroupProfEntry
- Table
- hwGBondGroupProfTable
- Siblings
- 15
Syntax
symbols GBondSymbolProtection
- Source
- GBondSymbolProtection
- Base type
Enumeration
Values & Constraints
Type Values
1 | noProtection |
2 | halfSymbol |
3 | singleSymbol |
4 | twoSymbols |
5 | threeSymbols |
6 | fourSymbols |
7 | fiveSymbols |
8 | sixSymbols |
9 | sevenSymbols |
10 | eightSymbols |
11 | nineSymbols |
12 | tenSymbols |
13 | elevenSymbols |
14 | twelveSymbols |
15 | thirteeSymbols |
16 | fourteenSymbols |
17 | fifteenSymbols |
18 | sixteenSymbols |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwGBondGroupProfName This object identifies a row in this table. | column | OctetString | .1.3.6.1.4.1.2011.6.137.6.1.1 |
| hwGBondGroupProfTargetDataRateUs A desired G.Bond port data rate in the upstream direction,
in Kbps, to be achieved during initialization, under
restrictions placed upon the member BCEs by their respective
config… | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.10 |
| hwGBondGroupProfTargetDataRateDs A desired G.Bond port data rate in the downstream direction,
in Kbps, to be achieved during initialization, under
restrictions placed upon the member BCEs by their respective
conf… | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.11 |
| hwGBondGroupProfThreshLowDataRateUs This object configures the G.Bond port low upstream rate
crossing alarm threshold. The value of 0 means that the
low upstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.12 |
| hwGBondGroupProfThreshLowDataRateDs This object configures the G.Bond port low downstream rate
crossing alarm threshold. The value of 0 means that the
low downstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.13 |
| hwGBondGroupProfLowRateCrossingEnable Indicates whether hwGBondLowUpRateCrossingAlarmTrap and hwGBondLowDownRateCrossingAlarmTrap
notifications should be generated for this interface.
Options:
1. enable(1) - I… | column | Enumeration | .1.3.6.1.4.1.2011.6.137.6.1.14 |
| hwGBondGroupProfRowStatus This object is used to create a new row or delete an existing row
in this table. Before a profile can be deleted, it must be not
referenced from all associated bonding group. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.2011.6.137.6.1.15 |
| hwGBondGroupProfBondCpeIncorrectAlarmSwitch This object enable/disable the bonding CPE incorrect alarm switch.
Options:
1. enable(1) - The bonding CPE incorrect alarm switch is enabled
2. disable(2) - The bonding CPE inco… | column | Enumeration | .1.3.6.1.4.1.2011.6.137.6.1.16 |
| hwGBondGroupProfMaxDelayUs This parameter is the maximum one-way interleaving delay introduced
by the PMS-TC on upstream direction. | column | milliseconds Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.2 |
| hwGBondGroupProfMaxDelayDs This parameter is the maximum one-way interleaving delay introduced
by the PMS-TC on downstream direction. | column | milliseconds Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.3 |
| hwGBondGroupProfMinProtectionUs This parameter is minimum impulse noise protection for the bearer channel
in the upstream direction, expressed in symbols. The parameter can take the
following values: noProtecti… | column | symbols GBondSymbolProtection | .1.3.6.1.4.1.2011.6.137.6.1.4 |
| hwGBondGroupProfMinDataRateUs This parameter specifics minimum data rate for the bearer channel
in the upstream direction. The value of 0 means that the minimum
upstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.6 |
| hwGBondGroupProfMinDataRateDs This parameter specifics minimum data rate for the bearer channel
in the downstream direction. The value of 0 means that the minimum
downstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.7 |
| hwGBondGroupProfMaxDataRateUs This parameter specifics maximum data rate for the bearer channel
in the upstream direction. The value of 0 means that the maximum
upstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.8 |
| hwGBondGroupProfMaxDataRateDs This parameter specifics maximum data rate for the bearer channel
in the downstream direction. The value of 0 means that the maximum
downstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.9 |