hwGBondGroupProfEntry
HUAWEI-GBOND-MIB ·
.1.3.6.1.4.1.2011.6.137.6.1
Object
row
The table hwGBondGroupProfTable contains the bonding group profile configuration. A default profile with an index of 'DEFVAL' will always exist and its parameters will be set to vendor-specific values, unless otherwise specified in this document. The index of this entry is hwGBondGroupProfName.
Context
- MIB
- HUAWEI-GBOND-MIB
- OID
.1.3.6.1.4.1.2011.6.137.6.1- Type
- row
- Status
- current
- Parent
- hwGBondGroupProfTable
- Table
- hwGBondGroupProfTable
- Children
- 16
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwGBondGroupProfName This object identifies a row in this table. | column | OctetString | .1.3.6.1.4.1.2011.6.137.6.1.1 |
| hwGBondGroupProfTargetDataRateUs A desired G.Bond port data rate in the upstream direction,
in Kbps, to be achieved during initialization, under
restrictions placed upon the member BCEs by their respective
config… | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.10 |
| hwGBondGroupProfTargetDataRateDs A desired G.Bond port data rate in the downstream direction,
in Kbps, to be achieved during initialization, under
restrictions placed upon the member BCEs by their respective
conf… | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.11 |
| hwGBondGroupProfThreshLowDataRateUs This object configures the G.Bond port low upstream rate
crossing alarm threshold. The value of 0 means that the
low upstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.12 |
| hwGBondGroupProfThreshLowDataRateDs This object configures the G.Bond port low downstream rate
crossing alarm threshold. The value of 0 means that the
low downstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.13 |
| hwGBondGroupProfLowRateCrossingEnable Indicates whether hwGBondLowUpRateCrossingAlarmTrap and hwGBondLowDownRateCrossingAlarmTrap
notifications should be generated for this interface.
Options:
1. enable(1) - I… | column | Enumeration | .1.3.6.1.4.1.2011.6.137.6.1.14 |
| hwGBondGroupProfRowStatus This object is used to create a new row or delete an existing row
in this table. Before a profile can be deleted, it must be not
referenced from all associated bonding group. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.2011.6.137.6.1.15 |
| hwGBondGroupProfBondCpeIncorrectAlarmSwitch This object enable/disable the bonding CPE incorrect alarm switch.
Options:
1. enable(1) - The bonding CPE incorrect alarm switch is enabled
2. disable(2) - The bonding CPE inco… | column | Enumeration | .1.3.6.1.4.1.2011.6.137.6.1.16 |
| hwGBondGroupProfMaxDelayUs This parameter is the maximum one-way interleaving delay introduced
by the PMS-TC on upstream direction. | column | milliseconds Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.2 |
| hwGBondGroupProfMaxDelayDs This parameter is the maximum one-way interleaving delay introduced
by the PMS-TC on downstream direction. | column | milliseconds Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.3 |
| hwGBondGroupProfMinProtectionUs This parameter is minimum impulse noise protection for the bearer channel
in the upstream direction, expressed in symbols. The parameter can take the
following values: noProtecti… | column | symbols GBondSymbolProtection | .1.3.6.1.4.1.2011.6.137.6.1.4 |
| hwGBondGroupProfMinProtectionDs This parameter is minimum impulse noise protection for the bearer channel
in the downstream direction, expressed in symbols. The parameter can take the
following values: noProtec… | column | symbols GBondSymbolProtection | .1.3.6.1.4.1.2011.6.137.6.1.5 |
| hwGBondGroupProfMinDataRateUs This parameter specifics minimum data rate for the bearer channel
in the upstream direction. The value of 0 means that the minimum
upstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.6 |
| hwGBondGroupProfMinDataRateDs This parameter specifics minimum data rate for the bearer channel
in the downstream direction. The value of 0 means that the minimum
downstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.7 |
| hwGBondGroupProfMaxDataRateUs This parameter specifics maximum data rate for the bearer channel
in the upstream direction. The value of 0 means that the maximum
upstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.8 |
| hwGBondGroupProfMaxDataRateDs This parameter specifics maximum data rate for the bearer channel
in the downstream direction. The value of 0 means that the maximum
downstream data rate is not fixed. | column | Kbps Unsigned32 | .1.3.6.1.4.1.2011.6.137.6.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwGBondGroupProfName This object identifies a row in this table. | column | OctetString | .1.3.6.1.4.1.2011.6.137.6.1.1 |