Sets the monitoring of the device temperature.
Context
- MIB
- HM2-DIAGNOSTIC-MIB
- OID
.1.3.6.1.4.1.248.11.22.1.3.1.1.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hm2SigConCommonEntry
- Table
- hm2SigConCommonTable
- Siblings
- 17
Syntax
HM2-TC-MIBHmEnabledStatus
- Source
- HM2-TC-MIBHmEnabledStatus
- Base type
Enumeration
Values & Constraints
Type Values
1 | enable |
2 | disable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hm2SigConID This index is used to identify the associated signalling contact. | column | Integer32 | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.1 |
| hm2SigConSenseFan Sets the monitoring of the device fan modules. | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.11 |
| hm2SigConSenseModuleRemoval Sets the monitoring of module removal (platform dependant). | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.12 |
| hm2SigConSenseExtNvmRemoval Sets the monitoring of the external non-volatile memory removal. | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.13 |
| hm2SigConSenseExtNvmNotInSync Sets the monitoring whether the external non-volatile memory is in
sync with the configuration in NVRAM. | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.14 |
| hm2SigConSenseRingRedundancy Sets the monitoring of the ring redundancy. | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.15 |
| hm2SigConSenseEthernetLoops Sets the monitoring for Ethernet loops. | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.16 |
| hm2SigConSenseHumidity Sets the monitoring of the device humidity. | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.17 |
| hm2SigConSenseStpPortBlock Sets the monitoring for STP loops. | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.18 |
| hm2SigConTrapEnable Determines whether a trap shall be sent or not, when
the signal contact operating state changes. | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.2 |
| hm2SigConTrapCause This object identifies the cause for a trap.
The index of the entity which produces the trap
is specified by hm2SigConTrapCauseIndex. | column | Enumeration | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.3 |
| hm2SigConTrapCauseIndex This attribute specifies the entity which produces the trap.
power-supply: index of power-supply table
link-failure: index of interface table
temperature: 0
ext-nvm-removal… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.4 |
| hm2SigConMode This attribute specifies the behavior of the relay contact.
The factory settings for signal contact 1 is monitoring the
correct operation of entries specified to be survived.
When… | column | Enumeration | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.5 |
| hm2SigConOperState This attribute shows the current operating state of the
signal contact. | column | Enumeration | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.6 |
| hm2SigConOperTimeStamp This attribute shows local system time (hm2SystemLocalTime) of the last hm2SigConOperState change. | column | HM2-TC-MIBHmTimeSeconds1970 | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.7 |
| hm2SigConManualActivate When operating in manual mode, the signal contact state can
be set by this attribute. | column | Enumeration | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.8 |
| hm2SigConSenseLinkFailure Sets the monitoring of the network connection(s). | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.22.1.3.1.1.1.9 |