upsIdentfirst
GEPARALLELUPS-MIB ·
.1.3.6.1.4.1.818.1.1.11.1
Object
node
No description available.
Context
- MIB
- GEPARALLELUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.11.1- Type
- node
- Parent
- geFirstUPS
- Siblings
- 11
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
Enumerated Values
1 | on |
2 | off |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsGetSetfirst | node | - | .1.3.6.1.4.1.818.1.1.11.10 |
| geUPSTrapsfirst | node | - | .1.3.6.1.4.1.818.1.1.11.11 |
| upsDiagnosticfirst | node | - | .1.3.6.1.4.1.818.1.1.11.12 |
| upsBatteryfirst | node | - | .1.3.6.1.4.1.818.1.1.11.2 |
| upsInputfirst | node | - | .1.3.6.1.4.1.818.1.1.11.3 |
| upsOutputfirst | node | - | .1.3.6.1.4.1.818.1.1.11.4 |
| upsBypassfirst | node | - | .1.3.6.1.4.1.818.1.1.11.5 |
| upsAlarmfirst | node | - | .1.3.6.1.4.1.818.1.1.11.6 |
| upsTestfirst | node | - | .1.3.6.1.4.1.818.1.1.11.7 |
| upsControlfirst | node | - | .1.3.6.1.4.1.818.1.1.11.8 |
| upsConfigfirst | node | - | .1.3.6.1.4.1.818.1.1.11.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsIdentManufacturerfirst The name of the UPS manufacturer.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.11.1.1 |
| upsIdentModelfirst The UPS Model designation.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.11.1.2 |
| upsIdentUPSSoftwareVersionfirst The UPS firmware/software version(s). This variable
may or may not have the same value as
upsIdentAgentSoftwareVersion in some implementations.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.11.1.3 |
| upsIdentAgentSoftwareVersionfirst The UPS agent software version. This variable may or
may not have the same value as
upsIdentUPSSoftwareVersion in some implementations.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.11.1.4 |
| upsIdentNamefirst A string identifying the UPS. This object should be
set by the administrator.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.11.1.5 |
| upsIdentAttachedDevicesfirst A string identifying the devices attached to the
output(s) of the UPS. This object should be set by
the administrator.(*) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.11.1.6 |
| upsIdentUPSSerialNumberfirst The UPS serial number | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.11.1.7 |
| upsIdentComProtVersionfirst The IMV communication protocol version | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.818.1.1.11.1.8 |
| upsIdentOperatingTimefirst The present value of the operating time.
total 'on' time since UPS manufactured | scalar | seconds NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.11.1.9 |