upsBatteryfirst
GEPARALLELUPS-MIB ·
.1.3.6.1.4.1.818.1.1.11.2
Object
node
No description available.
Context
- MIB
- GEPARALLELUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.11.2- Type
- node
- Parent
- geFirstUPS
- Siblings
- 11
- Children
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
Enumerated Values
1 | onbypass |
2 | onInverter |
3 | onDetour |
4 | loadOff |
5 | other |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsIdentfirst | node | - | .1.3.6.1.4.1.818.1.1.11.1 |
| upsGetSetfirst | node | - | .1.3.6.1.4.1.818.1.1.11.10 |
| geUPSTrapsfirst | node | - | .1.3.6.1.4.1.818.1.1.11.11 |
| upsDiagnosticfirst | node | - | .1.3.6.1.4.1.818.1.1.11.12 |
| upsInputfirst | node | - | .1.3.6.1.4.1.818.1.1.11.3 |
| upsOutputfirst | node | - | .1.3.6.1.4.1.818.1.1.11.4 |
| upsBypassfirst | node | - | .1.3.6.1.4.1.818.1.1.11.5 |
| upsAlarmfirst | node | - | .1.3.6.1.4.1.818.1.1.11.6 |
| upsTestfirst | node | - | .1.3.6.1.4.1.818.1.1.11.7 |
| upsControlfirst | node | - | .1.3.6.1.4.1.818.1.1.11.8 |
| upsConfigfirst | node | - | .1.3.6.1.4.1.818.1.1.11.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsBatteryStatusfirst The indication of the capacity remaining in the UPS
system's batteries. A value of batteryNormal
indicates that the remaining run-time is greater than
upsConfigLowBattTime. A v… | scalar | Enumeration | .1.3.6.1.4.1.818.1.1.11.2.1 |
| upsSecondsOnBatteryfirst If the unit is on battery power, the elapsed time
since the UPS last switched to battery power, or the
time since the network management subsystem was last
restarted, whichever is… | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.11.2.2 |
| upsEstimatedMinutesRemainingfirst An estimate of the time to battery charge depletion
under the present load conditions if the utility power
is off and remains off, or if it were to be lost and
remain off.(*) | scalar | minutes PositiveInteger32 | .1.3.6.1.4.1.818.1.1.11.2.3 |
| upsEstimatedChargeRemainingfirst An estimate of the battery charge remaining expressed
as a percent of full charge.(*) | scalar | percent Integer32 | .1.3.6.1.4.1.818.1.1.11.2.4 |
| upsBatteryVoltagefirst The magnitude of the present battery voltage.(*) | scalar | 0.1 Volt DC NonNegativeInteger32 | .1.3.6.1.4.1.818.1.1.11.2.5 |
| upsBatteryCurrentfirst The present battery current.(*) | scalar | 0.1 Amp DC SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.11.2.6 |
| upsBatteryTemperaturefirst The ambient temperature at or near the UPS Battery
casing.(*) | scalar | degrees Centigrade SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.11.2.7 |
| upsBatteryRipplefirst The present DC link RMS voltage ripple.(*) | scalar | 0.1 Volt RMS SNMPv2-SMIInteger32 | .1.3.6.1.4.1.818.1.1.11.2.8 |