upsAlarmUpsOffAsRequested
GEPARALLELUPS-MIB ·
.1.3.6.1.4.1.818.1.1.10.6.3.12
Object
node
The entire UPS has shutdown as commanded.(*)
Context
- MIB
- GEPARALLELUPS-MIB
- OID
.1.3.6.1.4.1.818.1.1.10.6.3.12- Type
- node
- Status
- current
- Parent
- upsWellKnownAlarms
- Siblings
- 30
Syntax
No syntax metadata recorded.
Values & Constraints
Enumerated Values
1 | unknown |
2 | batteryNormal |
3 | batteryLow |
4 | batteryDepleted |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAlarmBatteryBad One or more batteries have been determined to require
replacement.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.1 |
| upsAlarmBypassBad The Bypass is out of tolerance.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.10 |
| upsAlarmOutputOffAsRequested The UPS has shutdown as requested, i.e., the output
is off.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.11 |
| upsAlarmChargerFailed An uncorrected problem has been detected within the
UPS charger subsystem.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.13 |
| upsAlarmUpsOutputOff The output of the UPS is in the off state.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.14 |
| upsAlarmUpsSystemOff The UPS system is in the off state.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.15 |
| upsAlarmFanFailure The failure of one or more fans in the UPS has been
detected.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.16 |
| upsAlarmFuseFailure The failure of one or more fuses has been detected.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.17 |
| upsAlarmGeneralFault A general fault in the UPS has been detected.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.18 |
| upsAlarmDiagnosticTestFailed The result of the last diagnostic test indicates a
failure.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.19 |
| upsAlarmOnBattery The UPS is drawing power from the batteries.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.2 |
| upsAlarmCommunicationsLost A problem has been encountered in the communications
between the agent and the UPS.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.20 |
| upsAlarmAwaitingPower The UPS output is off and the UPS is awaiting the
return of input power.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.21 |
| upsAlarmShutdownPending A upsShutdownAfterDelay countdown is underway.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.22 |
| upsAlarmShutdownImminent The UPS will turn off power to the load in less than
5 seconds; this may be either a timed shutdown or a
low battery shutdown.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.23 |
| upsAlarmTestInProgress A test is in progress, as initiated and indicated by
the Test Group. Tests initiated via other
implementation-specific mechanisms can indicate the
presence of the testing in the … | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.24 |
| upsAlarmReceptacleOff The receptacle are switch off | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.25 |
| upsAlarmHighSpeedBusFailure A problem on the High Speed Bus communication is detected | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.26 |
| upsAlarmHighSpeedBusJACRCFailure A CRC problem on the Highspeed Bus JA is detected. | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.27 |
| upsAlarmConnectivityBusFailure A problem on the Connectivity Bus communication is detected | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.28 |
| upsAlarmHighSpeedBusJBCRCFailure A CRC problem on the Highspeed Bus JB is detected. | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.29 |
| upsAlarmLowBattery The remaining battery run-time is less than or equal
to upsConfigLowBattTime.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.3 |
| upsAlarmCurrentSharing The System detects an high current sharing on the parallel system | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.30 |
| upsAlarmDCRipple The System detects an high ripple voltage on one DC link | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.31 |
| upsAlarmDepletedBattery The UPS will be unable to sustain the present load
when and if the utility power is lost.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.4 |
| upsAlarmTempBad A temperature is out of tolerance.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.5 |
| upsAlarmInputBad An input condition is out of tolerance.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.6 |
| upsAlarmOutputBad An output condition (other than OutputOverload) is
out of tolerance.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.7 |
| upsAlarmOutputOverload The output load exceeds the UPS output capacity.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.8 |
| upsAlarmOnBypass The Bypass is presently engaged on the UPS.(*) | node | - | .1.3.6.1.4.1.818.1.1.10.6.3.9 |