upsESystemConfigOutputVoltage
EPPC-MIB ·
.1.3.6.1.4.1.935.10.1.1.2.7
Object
The magnitude of the nominal output voltage presented in 0.1V. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2
Context
- MIB
- EPPC-MIB
- OID
.1.3.6.1.4.1.935.10.1.1.2.7- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsESystemSummary
- Siblings
- 21
Values & Constraints
Type Constraints
range: 0..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsESystemStatus mandatory The indication of UPS system status. | scalar | Enumeration | .1.3.6.1.4.1.935.10.1.1.2.1 |
| upsESystemConfigOutputPower mandatory The magnitude of the nominal true power rating presented in W . | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.10 |
| upsESystemConfigOutputLoadHighSetPoint mandatory The maximum output load allowed before the load is too high for
UPS operation | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.11 |
| upsESystemConfigOverTemperatureSetPoint mandatory The maximum temperature allowed before the UPS
operation temperature is too high, presented in 0.1 degree. | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.12 |
| upsESystemInputSourceNum mandatory The present external source of input power. | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.2.13 |
| upsESystemInputLineBads mandatory The number of times the Input was out of tolerance in voltage or frequency.
Its value should be initialized 0 after agent restarting. | scalar | RFC1155-SMICounter | .1.3.6.1.4.1.935.10.1.1.2.14 |
| upsESystemInputNumPhases mandatory The number of input phase utilized is this device, serves as the table index.
This value indicate the device initialized feature. | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.2.15 |
| upsESystemInputTable mandatory A list of input table entries. The number of entries is given by the
value of upsESystemInputNumPhase. | table | - | .1.3.6.1.4.1.935.10.1.1.2.16 |
| upsESystemOutputNumPhase mandatory The number of metered output phases, serves as the table index.
This value indicate the device initialized feature. | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.2.17 |
| upsESystemOutputTable mandatory A list of output table entries. The number of entries is given
by the value of upsESystemOutputNumPhase. | table | - | .1.3.6.1.4.1.935.10.1.1.2.18 |
| upsESystemBypassNumPhase mandatory The number of bypass phases, serves as the table index.
This value indicate the device initialized feature | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.2.19 |
| upsESystemTemperature mandatory The temperature of UPS presented in 0.1 degree. | scalar | Integer32 | .1.3.6.1.4.1.935.10.1.1.2.2 |
| upsESystemBypassTable mandatory A list of bypass table entries. The number of entries is given by the
value of upsESystemBypassNumPhase. | table | - | .1.3.6.1.4.1.935.10.1.1.2.20 |
| upsESystemConfigBelowCapacityLimit mandatory The UPS batteries capacity(%) limit for shutdown | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.21 |
| upsESystemConfigBelowRemainTimeLimit mandatory The UPS batteries backup time(minute) limit for shutdown | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.22 |
| upsESystemWarningCode mandatory The warning code of UPS. Please refer the warning table
of 'Q6' for details. | scalar | OctetString | .1.3.6.1.4.1.935.10.1.1.2.3 |
| upsESystemFaultCode mandatory The fault code of UPS.Please refer the fault code
of 'Q6' for details. | scalar | OctetString | .1.3.6.1.4.1.935.10.1.1.2.4 |
| upsESystemConfigInputVoltage mandatory The magnitude of the nominal input voltage presented in 0.1 V. On those
systems which support read-write access to this object, if there is an
attempt to set this variable to a… | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.5 |
| upsESystemConfigInputFrequence mandatory The nominal input frequency presented in 0.1 Hz. On those systems which support
read-write access to this object, if there is an attempt to
set this variable to a value that is … | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.6 |
| upsESystemConfigOutputFrequency mandatory The nominal output frequency presented in 0.1Hz. On those systems which support
read-write access to this object, if there is an attempt to set
this variable to a value that is … | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.8 |
| upsESystemConfigOutputVA mandatory The magnitude of the nominal Volt-Amp rating presented in VA. | scalar | UPS-MIBNonNegativeInteger | .1.3.6.1.4.1.935.10.1.1.2.9 |