nvramEnvAlert

DATA-DOMAIN-MIB · .1.3.6.1.4.1.19746.2.0.6505

Object

notification
Description: 
The temperature sensor on the NVRAM card or the remote battery detected a temperature 
that is higher than the warning threshold.  If there are other environmental alerts, 
this may indicate a cooling problem where the system is installed.  
If there are no other environmental alerts, this may indicate a problem with this component.  
When the temperature is reduced, this alert will clear.
          
Action: 
Check cooling and airflow around the system unit.  Remove any blockage, or ensure 
the environmental systems are operating correctly, and the environment is at a normal 
temperature.  If there is no problem in the environment, or if only the NVRAM or 
remote battery are reporting this problem, contact your contracted support provider or visit us online at https://support.emc.com.