diskSASHBAAlarm
DATA-DOMAIN-MIB ·
.1.3.6.1.4.1.19746.2.0.25
Object
notification
deprecated
Meaning: Unsupported multi-path setting is enabled in the hba firmware. What to do: contact Data Domain support.
Context
- MIB
- DATA-DOMAIN-MIB
- OID
.1.3.6.1.4.1.19746.2.0.25- Type
- notification
- Status
- deprecated
- Parent
- dataDomainMibTraps
- Siblings
- 243
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| powerSupplyFailedAlarm deprecated Meaning: Power Supply failed
What to do: replace the power supply | notification | - | .1.3.6.1.4.1.19746.2.0.1 |
| fileSpaceWarningAlarm deprecated Meaning: A File System Resource space is 90% utilized. The index value of the alarm indicates
the file system index that may be looked up in the fileSystem table 'fileSystemSpac… | notification | - | .1.3.6.1.4.1.19746.2.0.10 |
| unsupportedEnclosurePSU Description:
A power supply has been detected in an enclosure which does not provide complete environmental information.
This will not affect normal operations but should be rep… | notification | - | .1.3.6.1.4.1.19746.2.0.10000 |
| unsupportedPowerSupply Description:
The installed power supply is an unsupported model.
The system may exhibit unexpected behavior.
Action:
Replace the power supply with a supported model.
… | notification | - | .1.3.6.1.4.1.19746.2.0.10001 |
| openFanDrawer Description:
Fan drawer is not closed securely.
Failure to secure the fan drawer may allow the system to overheat and shut down.
Action:
Close and secure the fan draw… | notification | - | .1.3.6.1.4.1.19746.2.0.10002 |
| memoryRiserFault Description:
A critical failure has been detected in a memory riser.
Memory attached to this riser may disappear from the system inventory.
The system may exhibit unexpected beha… | notification | - | .1.3.6.1.4.1.19746.2.0.10003 |
| pCILinkDegraded Description:
The system has detected that PCI communication speed is degraded.
This will not cause the system to fail but may impact performance of affected components.
… | notification | - | .1.3.6.1.4.1.19746.2.0.10004 |
| invalidHardwareCritical Description:
During device inventory verification, the system found missing or invalid hardware, or devices installed in the wrong location.
The filesystem cannot be enabled wit… | notification | - | .1.3.6.1.4.1.19746.2.0.10005 |
| invalidHardwareWarning Description:
During device inventory verification, the system found missing or invalid hardware, or devices installed in the wrong location.
Some components may not operate as e… | notification | - | .1.3.6.1.4.1.19746.2.0.10006 |
| correctableErrorWarning Description:
The system has detected excessive correctable errors on a component that may indicate a hardware failure.
Action:
Contact your contracted support provid… | notification | - | .1.3.6.1.4.1.19746.2.0.10007 |
| spuriousInterruptDisabled Description:
Excessive spurious hardware messages have been detected that may indicate a hardware failure.
Action:
Contact your contracted support provider or visit u… | notification | - | .1.3.6.1.4.1.19746.2.0.10008 |
| corruptEncryptionKeys Description:
File system was locked as the encryption keys cannot not be validated. One or more
encryption keys could be corrupt.
Action:
Contact your contracted sup… | notification | - | .1.3.6.1.4.1.19746.2.0.10009 |
| duplicateVTLPoolNames Description:
VTL directory pool and a VTL mtree pool have been detected with the same name.
Viewing pool information will only retrieve tapes from the mtree pool. Tapes in the
di… | notification | - | .1.3.6.1.4.1.19746.2.0.10010 |
| generalHardwareFailure Description:
A critical failure has been detected in one or more chassis components.
The system may exhibit unexpected behavior.
Action:
Contact your contracted suppo… | notification | - | .1.3.6.1.4.1.19746.2.0.10011 |
| iOModuleMacFault Description:
A Mac fault has been detected with an I/O module and it will not function correctly.
Action:
The I/O module must be replaced.Contact your contracted supp… | notification | - | .1.3.6.1.4.1.19746.2.0.10013 |
| storageMigrationCannotResume Description:
The system has detected a condition which prevented the storage
migration from continuing and has suspended the data copy phase.
Action:
Contact your con… | notification | - | .1.3.6.1.4.1.19746.2.0.10500 |
| storageMigrationCopyComplete Description: … | notification | - | .1.3.6.1.4.1.19746.2.0.10501 |
| storageMigrationUserSuspend Description:
An administrator has suspended the data copy phase of storage migration.
Data copy cannot proceed until it is manually resumed.
Action:
Resume the storag… | notification | - | .1.3.6.1.4.1.19746.2.0.10502 |
| cMTaskEnded Description:
A long running task has ended.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | notification | - | .1.3.6.1.4.1.19746.2.0.10503 |
| physicalCapacityMeasurementTasksLost Description:
File system has been disabled either by a failure or user action.
Physical-capacity-measurement samples for these tasks are no longer available.
Action:
… | notification | - | .1.3.6.1.4.1.19746.2.0.10504 |
| physicalCapacityMeasurementTasksLostMTree Description:
MTree replication was broken or resynced causing one or more physical-capacity-measurement sample tasks to be cancelled.
Physical-capacity-measurement samples for th… | notification | - | .1.3.6.1.4.1.19746.2.0.10505 |
| physicalCapacityMeasurementScheduleFailed Description:
A physical-capacity-measurement sample task that was scheduled to run was unable to start due to an error.
Some or all of the physical-capacity-measurement samples f… | notification | - | .1.3.6.1.4.1.19746.2.0.10506 |
| historicalDatabaseFailoverError Description:
Historical database failover failed.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
to help debug the pro… | notification | - | .1.3.6.1.4.1.19746.2.0.10507 |
| hAdegraded Description:
A condition has been detected causing the configured HA system to be degraded.
Any failover attempt will not succeed.
Action:
Display the HA detailed sta… | notification | - | .1.3.6.1.4.1.19746.2.0.10508 |
| upgradeInProgress Description:
DD OS upgrade is in progress.
The system will not be available for backup and restore operations.
The alert will be cleared after the upgrade operation is complete.
… | notification | - | .1.3.6.1.4.1.19746.2.0.10509 |
| hAofflineErrors Description:
Critical system errors have been detected causing the configured HA system to be in offline state.
Access to system services may be unavailable.
Action:
… | notification | - | .1.3.6.1.4.1.19746.2.0.10510 |
| suspendedMReplMissingUnits Description:
Mtree replication on this context cannot continue until all archive units used by this Mtree are online.
Replication will resume automatically once all archive units… | notification | - | .1.3.6.1.4.1.19746.2.0.10511 |
| foreignPack Description:
The enclosure pack is unusable by the file system.
Storage configuration can not be modified while a foreign device is present.
Action:
If this is expect… | notification | - | .1.3.6.1.4.1.19746.2.0.10512 |
| vDiskSCSITargetMismatch Description:
VDisk configuration does not match SCSI Target configuration.
Non-matching devices are not available and must be deleted or repaired.
Action:
Contact you… | notification | - | .1.3.6.1.4.1.19746.2.0.10513 |
| hATimeOutOfSync Description:
Timestamps of logs and system events will not match between the HA nodes.
This condition will not have an effect on HA functionality or system operation.
… | notification | - | .1.3.6.1.4.1.19746.2.0.10514 |
| enclosureMixDriveType Description:
An unsupported mix of enclosures with different drive types may impact performance and lead to unexpected system behavior.
Action:
Recable the enclosures… | notification | - | .1.3.6.1.4.1.19746.2.0.10515 |
| fileSpaceSevereAlarm deprecated Meaning: A File System Resource space is 95% utilized. The index value of the alarm indicates
the file system index that may be looked up in the fileSystem table 'fileSystemSpac… | notification | - | .1.3.6.1.4.1.19746.2.0.11 |
| fileSpaceCriticalAlarm deprecated Meaning: A File System Resource space is 100% utilized. The index value of the alarm indicates
the file system index that may be looked up in the fileSystem table 'fileSystemSpa… | notification | - | .1.3.6.1.4.1.19746.2.0.12 |
| diskFailedAlarm deprecated Meaning: some problem has been detected about the indicated disk. The index value
of the alarm indicates the disk index that may be looked up in the disk tables
'diskProperties… | notification | - | .1.3.6.1.4.1.19746.2.0.14 |
| diskOverheatWarningAlarm deprecated Meaning: the temperature reading of the indicated disk has exceeded the 'warning'
temperature level. If it continues to rise, it may eventually trigger a
shutdown of the DDR. … | notification | - | .1.3.6.1.4.1.19746.2.0.15 |
| diskOverheatAlertAlarm deprecated Meaning: the temperature reading of the indicated disk is more than halfway between
the 'warning' and 'shutdown' temperature levels. If it continues to rise, it will
trigger a sh… | notification | - | .1.3.6.1.4.1.19746.2.0.16 |
| diskOverheatShutdownAlarm deprecated Meaning: the temperature reading of the indicated disk has surpassed the 'shutdown'
temperature level. The DDR will be shutdown. The index value of the alarm indicates
the disk… | notification | - | .1.3.6.1.4.1.19746.2.0.17 |
| raidReconSevereAlarm deprecated Meaning: A raid group is MAX degraded with no reconstruction after less than 71 hours or
A disk group is degraded with none max degraded with no reconstruction. This alarm is sen… | notification | - | .1.3.6.1.4.1.19746.2.0.18 |
| raidReconCriticalAlarm deprecated Meaning: Raid group is MAX degraded with no reconstruction after 71 hours. This can
happen due to a disk failing at run-time or boot-up.
What to do: the disk should be replaced to… | notification | - | .1.3.6.1.4.1.19746.2.0.19 |
| systemOverheatWarningAlarm deprecated Meaning: the temperature reading of one of the thermometers in the Chassis has exceeded
the 'warning' temperature level. If it continues to rise, it may eventually trigger a
s… | notification | - | .1.3.6.1.4.1.19746.2.0.2 |
| raidReconCriticalShutdownAlarm deprecated Meaning: Raid group is MAX degraded with no reconstruction after 71 hours. This can
happen due to a disk failing at run-time or boot-up.
What to do: the disk must be replaced. | notification | - | .1.3.6.1.4.1.19746.2.0.20 |
| raidGroupMissingAlarm deprecated Meaning: one or more raid groups are missing.
What to do: disk may need replacement, or raid administration may be necessary. | notification | - | .1.3.6.1.4.1.19746.2.0.21 |
| diskNoSpareAlarm deprecated Meaning: there is no spare available for the raid group.
What to do: disk may need replacement, or raid administration may be necessary. | notification | - | .1.3.6.1.4.1.19746.2.0.22 |
| diskPathAlarm deprecated Meaning: multipath configuration is experiencing a problem. The number of paths set up is less than
the required number of paths. Disk index is the first disk in the enclosure … | notification | - | .1.3.6.1.4.1.19746.2.0.23 |
| diskSASAlarm deprecated Meaning: SAS configuration error. Maximum enclosures has been reached, or there
is a topology problem.
What to do: SAS configuration documentation should be consulted. administ… | notification | - | .1.3.6.1.4.1.19746.2.0.24 |
| snapshotFullAlarm deprecated Meaning: maximum number of snapshots has been reached.
What to do: expire some old snapshots to make room. | notification | - | .1.3.6.1.4.1.19746.2.0.26 |
| snapshotHWMAlarm deprecated Meaning: the number of snapshots has exceeded a predefined percentage (current 90%) of the maximum.
What to do: begin expiring snapshots so that the maximum is not reached. | notification | - | .1.3.6.1.4.1.19746.2.0.27 |
| clusterNodeAlarm deprecated Meaning: node is not reachable on any network interface.
What to do: check status of network and wiring. if that fails, try
rebooting the node. | notification | - | .1.3.6.1.4.1.19746.2.0.28 |
| clusterInterfaceAlarm deprecated Meaning: one interface of the cluster node is down.
What to do: check status of network and wiring. if that fails, try
rebooting the node. | notification | - | .1.3.6.1.4.1.19746.2.0.29 |
| systemOverheatAlertAlarm deprecated Meaning: the temperature reading of one of the thermometers in the Chassis is more than
halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, … | notification | - | .1.3.6.1.4.1.19746.2.0.3 |
| replSyncAlarm deprecated Meaning: a replication context is disabled due to nvram loss.
What to do: break replication on source and destination, then reconfigure
them and run replication sync. | notification | - | .1.3.6.1.4.1.19746.2.0.30 |
| systemStartupAlarm deprecated Meaning: system has rebooted or started. this does not indicate any abnormal activity.
What to do: nothing, unless reboot was triggered by other abnormal conditions, such as
temp… | notification | - | .1.3.6.1.4.1.19746.2.0.31 |
| filesysRelaunchAlarm deprecated Meaning: file system has undergone too many relaunches. it is probably unstable.
What to do: consult system logs. software or hardware restart may fix the malfunction. | notification | - | .1.3.6.1.4.1.19746.2.0.32 |
| filesysDDGCFailedAlarm deprecated Meaning: DDGC cleaning process has failed.
What to do: consult system logs. software or hardware restart may fix the malfunction. | notification | - | .1.3.6.1.4.1.19746.2.0.33 |
| filesysGeneralProblemAlarm deprecated Meaning: a general problem has occurred with the file system.
What to do: consult system logs. software or hardware restart may fix the malfunction. | notification | - | .1.3.6.1.4.1.19746.2.0.34 |
| diskUnsupportedAlarm deprecated Meaning: the model of the disk is unsupported by current DD platform. The index value
of the alarm indicates the disk index that may be looked up in the disk tables
'diskProper… | notification | - | .1.3.6.1.4.1.19746.2.0.35 |
| eventIPMIUnmanageAlarm deprecated Meaning: IPMI unmanaged alert detected.
What to do: check alert message | notification | - | .1.3.6.1.4.1.19746.2.0.36 |
| systemOverheatShutdownAlarm deprecated Meaning: the temperature reading of one of the thermometers in the Chassis has reached
or exceeded the 'shutdown' temperature level. The DDR will be shutdown to prevent damage
to … | notification | - | .1.3.6.1.4.1.19746.2.0.4 |
| fanModuleFailedAlarm deprecated Meaning: a Fan Module in the enclosure has failed. The index of the fan is given
as the index of the alarm. This same index can be looked up in the environmentals
table 'fanProp… | notification | - | .1.3.6.1.4.1.19746.2.0.5 |
| controllerUnreachableAlert Description:
This is a GDA event raised by the Master controller when it fails to reach a Worker
controller for more than 5 minutes. An unreachable Worker controller implies none… | notification | - | .1.3.6.1.4.1.19746.2.0.5002 |
| controllerIfaceUnreachableAlert Description:
This is a GDA event raised by the Master controller when it fails to reach a particular
Worker controller interface for more than 5 minutes. An unreachable interface… | notification | - | .1.3.6.1.4.1.19746.2.0.5003 |
| correctableECCLimitReached Description:
Single bit correctable ECC limit reached.
Action:
Replace the failed DIMM(s).
Contact your contracted support provider or visit us online at https://supp… | notification | - | .1.3.6.1.4.1.19746.2.0.5004 |
| uncorrectableECCerror Description:
Multi bit uncorrectable ECC error.
Action:
Replace the failed DIMM(s).
Contact your contracted support provider or visit us online at https://support.emc… | notification | - | .1.3.6.1.4.1.19746.2.0.5005 |
| legacyChassisTempWarning Description:
Current temperature sensor reading exceeds warning threshold.
Action:
Monitor temperature readings. If alert persists, check ambient room temperature and… | notification | - | .1.3.6.1.4.1.19746.2.0.5006 |
| legacyChassisTempCritical Description:
Current temperature sensor reading exceeds critical threshold.
Action:
Check ambient room temperature and for blocked air flow.
If the problem persists, … | notification | - | .1.3.6.1.4.1.19746.2.0.5007 |
| legacyPowerSupplyWarning Description:
A power supply has failed, is unplugged, or absent.
Action:
Check power supply cables and LED. Replace with other working power supply.
If there are outs… | notification | - | .1.3.6.1.4.1.19746.2.0.5008 |
| legacyFanWarning Description:
A fan has failed.
Action:
Check for any failed fan. If failed, replace with new fan.
If the problem persists, contact your contracted support provider or… | notification | - | .1.3.6.1.4.1.19746.2.0.5009 |
| powerSupplyWarning Description:
A power supply has failed, is unplugged, or absent.
Action:
Check power supply cables and LED. Replace with other working power supply.
If the problem pe… | notification | - | .1.3.6.1.4.1.19746.2.0.5010 |
| fanWarning Description:
A fan has failed or is missing.
Action:
Check for any failed or missing fan. Reseat the fan.
If the problem persists, contact your contracted support pro… | notification | - | .1.3.6.1.4.1.19746.2.0.5011 |
| voltageWarning Description:
Voltage sensor reading exceeds warning threshold.
Action:
If the problem persists, contact your contracted support provider or visit us online at https:/… | notification | - | .1.3.6.1.4.1.19746.2.0.5012 |
| powerWarning Description:
Current power consumption reading exceeds warning threshold.
Action:
If the problem persists, contact your contracted support provider or visit us online… | notification | - | .1.3.6.1.4.1.19746.2.0.5013 |
| correctECCWarning Description:
Memory correctable ECC errors exceed warning threshold.
Action:
These memory errors are automatically corrected by the system.
If the problem persists, … | notification | - | .1.3.6.1.4.1.19746.2.0.5014 |
| processorWarning Description:
Processor status sensor alert.
Action:
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | notification | - | .1.3.6.1.4.1.19746.2.0.5016 |
| powerUnitWarning Description:
This event is expected after power off, power cycle, or AC power loss event.
Action:
If this alert is not expected, check power cords and AC power.
If th… | notification | - | .1.3.6.1.4.1.19746.2.0.5017 |
| unCorrectECCWarning Description:
Memory uncorrectable ECC error alert.
Action:
If the problem persists, contact your contracted support provider or visit us online at https://support.emc… | notification | - | .1.3.6.1.4.1.19746.2.0.5018 |
| chassisSensorCritical Description:
Current sensor reading or state exceeds critical condition.
Action:
Check the specific alert message for information.
Monitor temperature readings. If al… | notification | - | .1.3.6.1.4.1.19746.2.0.5020 |
| chassisTempWarning Description:
Current temperature sensor reading exceeds warning threshold.
Action:
Monitor temperature readings. If alert persists, check ambient room temperature
an… | notification | - | .1.3.6.1.4.1.19746.2.0.5021 |
| chassisTempCritical Description:
Current temperature sensor reading exceeds critical threshold.
Action:
Check ambient room temperature and for blocked air flow.
If the problem persists,… | notification | - | .1.3.6.1.4.1.19746.2.0.5022 |
| cPUFailureWarning Description:
DDOS has detected a fault with the indicated CPU.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | notification | - | .1.3.6.1.4.1.19746.2.0.5023 |
| legacyBMCHangCritical Description:
While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational.
This could mask serious problems such as overheating.
A… | notification | - | .1.3.6.1.4.1.19746.2.0.5024 |
| bMCHangCritical Description:
While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational.
This could mask serious problems such as overheating.
A… | notification | - | .1.3.6.1.4.1.19746.2.0.5025 |
| abnormalShutdown Description:
The system has been shutdown by abnormal method, i.e. not by one of the following:
1) Via IPMI chassis control command
2) Via power button
3) Via OS shutdown
… | notification | - | .1.3.6.1.4.1.19746.2.0.5026 |
| tooManyRelaunches Description:
The filesystem has failed to restart after multiple attempts. Backup and restore services are unavailable.
Action:
Contact your contracted support provi… | notification | - | .1.3.6.1.4.1.19746.2.0.5027 |
| filesystemProblem Description:
A problem is preventing the filesystem from running. This usually
involves the storage being unavailable.
Action:
Check disk shelf cabling. If problem … | notification | - | .1.3.6.1.4.1.19746.2.0.5028 |
| dDFSFailedInShutdown Description:
The filesystem shut down encountered an error. This can potentially leave data in the NVRAM
which would be normally flushed to the disk. Failed shutdown can leave … | notification | - | .1.3.6.1.4.1.19746.2.0.5030 |
| dDFSNoHeartbeat Description:
Filesystem has encountered an error and is forced to restart.
Action:
If the problem persists, contact your contracted support provider or visit us onlin… | notification | - | .1.3.6.1.4.1.19746.2.0.5034 |
| dDFSDiedAfterReboot Description:
The filesystem failed to startup immediately after system reboot.
Action:
Contact your contracted support provider or visit us online at https://support.… | notification | - | .1.3.6.1.4.1.19746.2.0.5036 |
| dDFSDied Description:
The filesystem process failed and is restarting.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com for diagn… | notification | - | .1.3.6.1.4.1.19746.2.0.5037 |
| dDFSRebooted Description:
This is just a notification alert that the system has been rebooted.
Action:
No action required. | notification | - | .1.3.6.1.4.1.19746.2.0.5038 |
| dDFSRebootedDisabled Description:
This is a notification alert sent out during system startup following a
reboot. The system is rebooted with the filesystem in disabled state.
Action:
No… | notification | - | .1.3.6.1.4.1.19746.2.0.5039 |
| indexRebuildComplete Description:
The metadata rebuild operation that was started by support has completed. The system is ready for the next action.
Action:
Contact your contracted suppo… | notification | - | .1.3.6.1.4.1.19746.2.0.5040 |
| historicalDatabaseRecoverError Description:
All existing historical data has been lost. Data in the historical
database is used for some system reports, but it is not required for proper
system functioning. Th… | notification | - | .1.3.6.1.4.1.19746.2.0.5041 |
| historicalDatabaseBackupError Description:
Historical database backup failed. If the primary historical
database fails without a recent backup present, some or all of the historical
data can be lost when the … | notification | - | .1.3.6.1.4.1.19746.2.0.5042 |
| historicalDatabaseUpgradeError Description:
Historical database upgrade failed during software upgrade. New historical
data fields will not be saved. Some UI reports might be unavailable, or
be missing data.… | notification | - | .1.3.6.1.4.1.19746.2.0.5043 |
| historicalDatabasePruneError Description:
Historical database pruning failed. Pruning ensures the historical database
does not consume more than its allocated disk space.
Action:
Contact your co… | notification | - | .1.3.6.1.4.1.19746.2.0.5044 |
| noHistoricalDatabaseError Description:
Data in the historical database is used for some system reports,
but it is not required for proper system functioning. This failure may occur
during head swap proces… | notification | - | .1.3.6.1.4.1.19746.2.0.5045 |
| hDTFileTransferFailed Description:
Unable to send historical data update file to Data Domain Management Center.
Action:
Check DNS settings and network connection between the Data Domain
Sy… | notification | - | .1.3.6.1.4.1.19746.2.0.5046 |
| hDTSystemError Description:
System Error occurred while sending historical data to Data Domain Management Center.
Action:
Check configuration and system status, messages logs for in… | notification | - | .1.3.6.1.4.1.19746.2.0.5047 |
| dIMMFailureAlert Description:
DIMM failure detected. DDFS can't be enabled.
Action:
Replace the bad DIMMS. | notification | - | .1.3.6.1.4.1.19746.2.0.5048 |
| memoryAlert Description:
Current memory is less than configured. DDFS can't be enabled.
Action:
Check the DIMMS in DDR. Add new DIMMS and/or replace the bad DIMMS. | notification | - | .1.3.6.1.4.1.19746.2.0.5049 |
| portPathDisabled Description:
A path is disabled. Multipath failover will not work correctly until the port is enabled.
Action:
Verify all storage cabling is connected correctly.
If p… | notification | - | .1.3.6.1.4.1.19746.2.0.5050 |
| diskPathRedundancy Description:
Since only one HBA controller has been detected, disk path redundancy is lost.
Action:
If the HBA configuration is correct, disable multipath configurati… | notification | - | .1.3.6.1.4.1.19746.2.0.5051 |
| missingPortConnection Description:
A port and the attached storage have disappeared.
Action:
Verify the connection and any external storage connected to the missing port. | notification | - | .1.3.6.1.4.1.19746.2.0.5052 |
| missingLunPath Description:
The number of active paths to a LUN has changed.
Action:
If this is due to reconfiguration, verify the topology and disable then re-enable
multipath moni… | notification | - | .1.3.6.1.4.1.19746.2.0.5053 |
| missingDiskPath Description:
The number of active paths to a disk has decreased. Multipath redundancy has been lost
unless there are more than one connection paths.
Action:
Contact y… | notification | - | .1.3.6.1.4.1.19746.2.0.5054 |
| missingEnclosurePath Description:
The number of active paths to a disk has decreased. Multipath redundancy has been lost
unless there are more than one connection paths.
Action:
Use 'encl… | notification | - | .1.3.6.1.4.1.19746.2.0.5055 |
| nvramWarning Description:
DDFS is disabled due to a problem with the NVRAM subsystem.
Action:
Check for other NVRAM-related alerts and follow the action described in those alerts. | notification | - | .1.3.6.1.4.1.19746.2.0.5059 |
| nvramBatteryAlert Description:
DD OS detected an NVRAM card Battery Unit hardware fault.
Probable causes: 1) Battery charging is disabled, or 2) One or more batteries are not charging.
… | notification | - | .1.3.6.1.4.1.19746.2.0.5060 |
| nvramErrorAlert Description:
DD OS detected an NVRAM card fault.
Probable cause: Excessive correctable errors exceed the warning threshold number.
Action:
The NVRAM card may need to … | notification | - | .1.3.6.1.4.1.19746.2.0.5061 |
| phyalert Description:
Enclosure slot has been disabled due to continuous discovery caused by a failed drive.
Action:
Replace the failed drive.
Use 'disk rescan' command specif… | notification | - | .1.3.6.1.4.1.19746.2.0.5062 |
| replProgressThreshholdReached Description:
Collection replication has not made progress and there is data waiting to be replicated.
This means your replica is not up to date.
Action:
- check the … | notification | - | .1.3.6.1.4.1.19746.2.0.5063 |
| replNeedResync Description:
Replication will not proceed until this context is resynced.
Action:
To re-establish replication
- Note the context information
- break the cont… | notification | - | .1.3.6.1.4.1.19746.2.0.5064 |
| replLogFull Description:
No data can be written to the filesystem. Too much data remains to be replicated.
This can be caused by disabled contexts or slow replication.
When the condition is … | notification | - | .1.3.6.1.4.1.19746.2.0.5065 |
| replIncompatibleWorm Description:
New retention-locked files detected on destination during replication resync. Resync cannot proceed.
Action:
Break the existing context and resync to a n… | notification | - | .1.3.6.1.4.1.19746.2.0.5066 |
| replDestNotConfigured Description:
Replication context on the destination is missing or mis-matched. Cannot initialize context.
Action:
- Check both the source and destination configured c… | notification | - | .1.3.6.1.4.1.19746.2.0.5067 |
| replLagThreshholdReached Description:
Replication lag threshold has been exceeded.
Action:
Refer to the knowledge base on ways to resolve the replication lag. | notification | - | .1.3.6.1.4.1.19746.2.0.5068 |
| sASEnclosureCheck Description:
The number of enclosures connected to the port has exceeded the maximum supported limit.
This may cause an unexpected behavior.
Action:
Reduce the number… | notification | - | .1.3.6.1.4.1.19746.2.0.5069 |
| sASTopologyCheck Description:
Invalid cabling has been detected. This may cause unexpected behavior.
Action:
Refer to the cabling guide. Verify the connectivity of the SAS enclosures … | notification | - | .1.3.6.1.4.1.19746.2.0.5070 |
| sASPortDisabled Description:
Excessive errors have caused this port to be disabled. This could be caused by faulty cables or shelf controllers.
Action:
Contact your contracted suppor… | notification | - | .1.3.6.1.4.1.19746.2.0.5071 |
| sSLCertificateCorrupted Description:
The SSL certificate used to establish mutual trust between Data Domain systems is broken.
Action:
Contact your contracted support provider or vis… | notification | - | .1.3.6.1.4.1.19746.2.0.5072 |
| snapshotOver90Percent Description:
Current number of snapshots for an Mtree is at 90% or more of the maximum number of snapshots allowed.
Action:
Consider expiring existing snapshots of th… | notification | - | .1.3.6.1.4.1.19746.2.0.5075 |
| snapshotLimitReached Description:
Data Domain system has a limit on the number of existing snapshots held at once for a single Mtree.
Once this limit is reached no more snapshots can be created of th… | notification | - | .1.3.6.1.4.1.19746.2.0.5076 |
| sNTZMultipleIterations Description:
Indicates that sanitization will be run in multiple iterations.
In the worst case this can take 15-20 days for 280 TBs. It means
that the system will not run at ful… | notification | - | .1.3.6.1.4.1.19746.2.0.5077 |
| coredumpWarning Description:
/ddvar might soon run out of space to save system core dumps.
Action:
Remove unwanted files from /ddvar to free up some space.
Lack of space can result i… | notification | - | .1.3.6.1.4.1.19746.2.0.5078 |
| coredumpDisabled Description:
Space in /ddvar is not sufficient enough for saving system core dumps.
Action:
Remove unwanted files from /ddvar to free up some space.
Lack of space can… | notification | - | .1.3.6.1.4.1.19746.2.0.5079 |
| spaceOver80Percent Description:
Space usage has exceeded 80% of the total capacity.
Lack of space can result in missing important logs or loss of file system functionality.
Action:
If i… | notification | - | .1.3.6.1.4.1.19746.2.0.5080 |
| spaceOver90Percent Description:
Space usage has exceeded 90% of the total capacity.
Lack of space can result in missing important logs or loss of file system functionality.
Action:
If i… | notification | - | .1.3.6.1.4.1.19746.2.0.5081 |
| diskAccessError Description:
A hardware fault has been detected for this drive. The drive or the cabling to it may have a problem.
Action:
Contact your contracted support provider or… | notification | - | .1.3.6.1.4.1.19746.2.0.5082 |
| diskFailure Description:
Unable to communicate with a disk. This disk cannot be used at this time.
Action:
Contact your contracted support provider or visit us online at https://… | notification | - | .1.3.6.1.4.1.19746.2.0.5083 |
| diskTemperatureWarning Description:
The disk temperature has exceeded a specified threshold. If the temperature continues to increase,
the system could fail or the system could be shut down.
… | notification | - | .1.3.6.1.4.1.19746.2.0.5084 |
| diskTemperatureShutdown Description:
One or more disks have exceeded the shut down temperature threshold. The system is shutting down.
Action:
Verify the environment is at its normal tempera… | notification | - | .1.3.6.1.4.1.19746.2.0.5085 |
| unsupportedHardwareSpareSize Description:
The disk capacity is too small for it to be of any use in the system.
Action:
Replace with a larger capacity disk. | notification | - | .1.3.6.1.4.1.19746.2.0.5086 |
| missingDiskGroup Description:
One or more critical disks/LUNs are unavailable.
Action:
Make sure all storage is securely connected.
Look at alert history for any path failures.
Check … | notification | - | .1.3.6.1.4.1.19746.2.0.5087 |
| diskGroupReconstructionNoProgress Description:
One or more disks are failed and the RAID reconstruction is not running.
Action:
Make sure there is/are spare disk(s) in the system. | notification | - | .1.3.6.1.4.1.19746.2.0.5088 |
| diskGroupReconstruction Description:
Two or more disks are failed and the RAID protection is in critical state.
If an additional disk fails, there might be permanent loss of data.
The system will shut d… | notification | - | .1.3.6.1.4.1.19746.2.0.5089 |
| diskGroupReconstructionShutdown Description:
Two or more disks are failed and the RAID protection is in critical state for over a
considerable period of time. If an additional disk fails, there might be permane… | notification | - | .1.3.6.1.4.1.19746.2.0.5090 |
| diskGroupReconstructionCritical Description:
Two or more disks are failed and the RAID protection is in critical state for over a
considerable period of time. If an additional disk fails, there might be permane… | notification | - | .1.3.6.1.4.1.19746.2.0.5091 |
| diskUnknown Description:
Disk is unknown.
Action:
Add disk to the system. | notification | - | .1.3.6.1.4.1.19746.2.0.5092 |
| lowSpares Description:
Not enough spare disks can be detected for this tier.
There may be failed disks or connectivity issues with disks or enclosures.
Action:
Replace any fail… | notification | - | .1.3.6.1.4.1.19746.2.0.5094 |
| unsupportedConfigurationROL Description:
Raid on LUN from 4.8 is no longer supported. Please follow instruction on how to increase
usable space in your filesystem.
Action:
1) migrate … | notification | - | .1.3.6.1.4.1.19746.2.0.5095 |
| cpismissing Description:
An archive unit is missing which could result in failure to access files in that unit.
Action:
- check power connection of each shelf.
- check data cable… | notification | - | .1.3.6.1.4.1.19746.2.0.5500 |
| containerMarkedInvalid Description:
The restorer filesystem has detected a data integrity check failure
due to hardware/software problems. There is potential for data loss or
corruption and needs immed… | notification | - | .1.3.6.1.4.1.19746.2.0.5501 |
| smiMrc Description:
BIOS SMI MRC interrupt
Action:
Check if system memory size has been decreased due to a DIMM has been disabled.
If yes, replace the bad DIMM.
If the probl… | notification | - | .1.3.6.1.4.1.19746.2.0.5502 |
| nvramBatteryLowChargeAlert Description:
The NVRAM battery is charging, but is below the threshold.
The filesystem will not start until the battery charge reaches the threshold.
Action:
Wait f… | notification | - | .1.3.6.1.4.1.19746.2.0.5508 |
| ext3NvlogDisabled Description:
DDOS RAID log is disabled due to a problem with the NVRAM subsystem.
Action:
Check for other NVRAM-related alerts and follow the action described in thos… | notification | - | .1.3.6.1.4.1.19746.2.0.5527 |
| enclosureMixType Description:
An unsupported mix of enclosure models have been detected. For example, a mixture of ES30s and ES20s.
Action:
Refer to the configuration guide for valid … | notification | - | .1.3.6.1.4.1.19746.2.0.5528 |
| replPathTooLong Description:
Path is too long
Action:
Shorten the path. | notification | - | .1.3.6.1.4.1.19746.2.0.5531 |
| nvramFailingAlarm deprecated Meaning: The system has detected that the NVRAM is potentially failing. There has
been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties'
and 'nvramS… | notification | - | .1.3.6.1.4.1.19746.2.0.6 |
| compromisedEncryptionKeys Description:
Data on disk may be at risk of disclosure. Data encrypted with
the compromised keys should be re-encrypted before shipping the disks.
One can get the list of comprom… | notification | - | .1.3.6.1.4.1.19746.2.0.6001 |
| newEncryptionKey Description:
Old key is still used for encrypting new data.
The file system needs to be restarted to activate the new key.
Action:
Restart the filesystem. | notification | - | .1.3.6.1.4.1.19746.2.0.6002 |
| encryptionKeyTableFull Description:
Encryption key table is full. No new keys can be added until some keys are
deleted.
Action:
Free up key table space by deleting an unused key and then ad… | notification | - | .1.3.6.1.4.1.19746.2.0.6003 |
| uncertifiedFirmware Description:
Firmware version is not compatible with this version of DDOS and may cause unexpected behavior.
Action:
The firmware must be updated as soon as possible,… | notification | - | .1.3.6.1.4.1.19746.2.0.6004 |
| filesystemNVRAMDataLoss Description:
Filesystem cannot be enabled because of NVRAM mismatch. This can happen because of an improper headswap or NVRAM card replacement operation.
Action:
Cont… | notification | - | .1.3.6.1.4.1.19746.2.0.6005 |
| mtreeQuotaSoftLimit Description:
The Soft Limit Quota for this MTree has been reached. This will not affect the operation of the system and is only a warning.
If a Quota Hard Limit is set for this … | notification | - | .1.3.6.1.4.1.19746.2.0.6007 |
| mtreeQuotaHardLimit Description:
The Hard Limit Quota for this MTree has been reached. No more data will be written to this MTree.
If a backup operation was running, it probably failed and must be r… | notification | - | .1.3.6.1.4.1.19746.2.0.6008 |
| interfaceConnectivityDown Description:
Network connectivity on this interface is down.
This interface is not pingable and cannot be used to send or receive any data.
All data transfers using this interfac… | notification | - | .1.3.6.1.4.1.19746.2.0.6009 |
| interfaceConnectivityIntermittent Description:
Network connectivity on this interface is intermittent. Data may not be sent or received successfully.
Data transfers using this interface may experience performanc… | notification | - | .1.3.6.1.4.1.19746.2.0.6010 |
| interfaceMisconfiguration Description:
Network interface configuration problem detected. This may be a result of changing the NIC hardware without reconfiguring the interface.
This could indicate an unsup… | notification | - | .1.3.6.1.4.1.19746.2.0.6011 |
| recoverFromNVRAMFailed Description:
Due to NVRAM issues, filesystem has been disabled in order to maintain data integrity.
No backups will run until this problem is resolved.
Action:
Contac… | notification | - | .1.3.6.1.4.1.19746.2.0.6013 |
| cleaningError Description:
Unable to reclaim unused space and this may impact the ability to backup.
Action:
Contact your contracted support provider or visit us online at https://… | notification | - | .1.3.6.1.4.1.19746.2.0.6014 |
| bMCPartialHang Description:
BMC firmware is not responsive.
Action:
Use CLI or Enterprise Manager to check fan, voltage, and power supply readings.
If the system fails to fetch the … | notification | - | .1.3.6.1.4.1.19746.2.0.6015 |
| fileMigrationError Description:
File migration is suspended until this problem is resolved.
Action:
Contact your contracted support provider or visit us online at https://support.emc.co… | notification | - | .1.3.6.1.4.1.19746.2.0.6016 |
| unusableHostCertificate Description:
Enterprise Manager will not start up using the imported certificate. However, it will start up using the default self-signed certificate.
Following is the list of p… | notification | - | .1.3.6.1.4.1.19746.2.0.6017 |
| missingHostCertificate Description:
The imported certificate is missing. However, the Enterprise Manager will start up using the default self-signed certificate.
Action:
If you want to use … | notification | - | .1.3.6.1.4.1.19746.2.0.6018 |
| foreignEnclosure Description:
The enclosure is unusable by the filesystem.
Storage configuration can not be modified while a foreign device is present.
Action:
If this is expected as … | notification | - | .1.3.6.1.4.1.19746.2.0.6019 |
| interfaceConnectivityUpAndRunning Description:
Network interface is up and running for a period of time after experiencing instability.
Action:
No action needed. | notification | - | .1.3.6.1.4.1.19746.2.0.6020 |
| tcpZeroWindowAlert Description:
The TCP connection is active but data is not being transferred.
This may cause other communication failures.
Action:
Check the remote application that us… | notification | - | .1.3.6.1.4.1.19746.2.0.6101 |
| insecureEncryptedReplication Description:
Encrypted replication is configured between this system and the remote host.
The remote host is running a DDOS version that does not support a fully secure communica… | notification | - | .1.3.6.1.4.1.19746.2.0.6102 |
| nvramHWAlert Description:
The NVRAM card is not in a usable state.
The file system cannot be accessed until the fault is corrected or the NVRAM card is replaced.
Action:
Contact y… | notification | - | .1.3.6.1.4.1.19746.2.0.6504 |
| nvramEnvAlert Description:
The temperature sensor on the NVRAM card or the remote battery detected a temperature
that is higher than the warning threshold. If there are other environmental a… | notification | - | .1.3.6.1.4.1.19746.2.0.6505 |
| nvramEventHWAlert Description:
NVRAM firmware detects an NVRAM card hardware fault.
Action:
The NVRAM card may need to be replaced. Contact your contracted support provider or visit us… | notification | - | .1.3.6.1.4.1.19746.2.0.6506 |
| nvramBattAlert Description:
The remote battery for an NVRAM card is not in a usable state.
The file system cannot be accessed until the fault is corrected or the NVRAM remote battery is replace… | notification | - | .1.3.6.1.4.1.19746.2.0.6507 |
| nvramCondAlert Description:
The NVRAM battery power or charging has been set as disabled.
This condition is either the result of an explicit setting, or indicates a fault
in the NVRAM card or… | notification | - | .1.3.6.1.4.1.19746.2.0.6508 |
| upgradeFailure Description:
During the upgrade process, there was an error that requires manual intervention. The system is not usable.
Action:
Contact your contracted support provi… | notification | - | .1.3.6.1.4.1.19746.2.0.6509 |
| upgradeCompleted Description:
The DD OS upgrade is completed successfully. The system will be ready to use when the filesystem is enabled.
Action:
No action required. | notification | - | .1.3.6.1.4.1.19746.2.0.6510 |
| mailserverError Description:
There is a problem communicating with the configured mail server.
The system will not be able to send out any email notifications that includes alerts, autosupports … | notification | - | .1.3.6.1.4.1.19746.2.0.6511 |
| invalidNICSlot Description:
Network interface cards must be installed in their designated slots.
The network card may not function correctly when installed in the wrong slot.
Action:… | notification | - | .1.3.6.1.4.1.19746.2.0.6512 |
| unsupportedNIC Description:
An unsupported network interface card is installed in the system.
Having an unsupported card installed in the system can cause unexpected errors.
Action: … | notification | - | .1.3.6.1.4.1.19746.2.0.6513 |
| sASHBAFailure Description:
Storage is no longer accessible through this HBA.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | notification | - | .1.3.6.1.4.1.19746.2.0.6514 |
| sASHBAErrors Description:
A SAS HBA has detected correctable errors exceeding the warning threshold.
This will reduce throughput and may indicate a failing HBA.
Action:
If this co… | notification | - | .1.3.6.1.4.1.19746.2.0.6515 |
| unsupportedSASDevice Description:
A SAS HBA has reported a device that is not recognized.
This device is not usable and may adversely affect the system.
Action:
Identify the device and re… | notification | - | .1.3.6.1.4.1.19746.2.0.6516 |
| fanFault Description:
A hardware fault has been detected in an enclosure cooling fan. This may allow the enclosure to overheat.
Action:
The fan must be replaced. Contact your … | notification | - | .1.3.6.1.4.1.19746.2.0.6517 |
| powerSupplyInputFault Description:
A power loss has been detected in an enclosure power supply. This can be caused by a loss of AC power to one power supply.
Action:
Check if AC main powe… | notification | - | .1.3.6.1.4.1.19746.2.0.6518 |
| powerSupplyFailure Description:
A power loss has been detected in an enclosure power supply. This can be caused by a failure in the power supply.
Action:
Power supply needs to be repla… | notification | - | .1.3.6.1.4.1.19746.2.0.6519 |
| powerSupplyAbsent Description:
An enclosure power supply is absent.
Action:
Power supply needs to be replaced. Contact your contracted support provider or visit us online at https://su… | notification | - | .1.3.6.1.4.1.19746.2.0.6520 |
| unsupportedACVoltage Description:
The power supply for this enclosure is connected to an unsupported AC voltage.
The system may operate at a reduced capacity or unexpectedly shut down.
Ac… | notification | - | .1.3.6.1.4.1.19746.2.0.6521 |
| iOModuleFault Description:
A fault has been detected with an I/O module and it will not function correctly.
Action:
The I/O module must be replaced.Contact your contracted support … | notification | - | .1.3.6.1.4.1.19746.2.0.6522 |
| iOModuleInserted Description:
An I/O module has been inserted during system runtime. The I/O module will not be powered on until the system is restarted.
Action:
Restart the system to… | notification | - | .1.3.6.1.4.1.19746.2.0.6523 |
| mgmtModuleFault Description:
A fault has been detected in the management I/O module. Management functions requiring the I/O module will not work.
Action:
The management I/O module mu… | notification | - | .1.3.6.1.4.1.19746.2.0.6524 |
| dIMMFailure Description:
A fault has been detected on a memory card. The memory may no longer be usable by the system and the system may not function with the reduced memory capacity.
… | notification | - | .1.3.6.1.4.1.19746.2.0.6525 |
| sPFault Description:
A fault has been detected on the storage processor. The system may experience unexpected behavior.
Action:
The failed storage processor must be replaced.… | notification | - | .1.3.6.1.4.1.19746.2.0.6526 |
| chassisFailure Description:
A fault has been detected in one of the chassis components. The system may experience unexpected behavior.
Action:
The chassis must be replaced.Contact … | notification | - | .1.3.6.1.4.1.19746.2.0.6527 |
| forcedControllerShutdown Description:
An environmental condition or hardware fault has been detected that may cause significant damage to the hardware or possible data loss, and the system unit is being … | notification | - | .1.3.6.1.4.1.19746.2.0.6528 |
| systemReset Description:
A critical failure caused the system to unexpectedly shut down.
The system was able to boot successfully either because the fault was corrected, the fault was transi… | notification | - | .1.3.6.1.4.1.19746.2.0.6529 |
| duplicateAddressDetection Description:
This IP address has been detected on the network. Connections to this IP address will be adversely impacted.
Action:
Make sure the local and remote syste… | notification | - | .1.3.6.1.4.1.19746.2.0.6530 |
| spaceReclRestartFailed Description:
Archive space reclamation was running before the last shutdown of the filesystem and could not be restarted automatically.
Space will not be reclaimed in the archive… | notification | - | .1.3.6.1.4.1.19746.2.0.6531 |
| spaceReclMissingUnit Description:
Archive units are missing. Space reclamation cannot run unless all configured units are attached.
Space will not be reclaimed in the archive tier until space reclama… | notification | - | .1.3.6.1.4.1.19746.2.0.6532 |
| spaceReclUnitReclaimed Description:
All space on the archive unit has been reclaimed. This unit is available to reuse.
Action:
No action is required. | notification | - | .1.3.6.1.4.1.19746.2.0.6533 |
| spaceReclError Description:
Archive space reclamation has stopped due to the specified error.
Space will not be reclaimed in the archive tier until the error condition is resolved and space rec… | notification | - | .1.3.6.1.4.1.19746.2.0.6534 |
| enclosureHighTemp Description:
The temperature inside the enclosure is high and has exceeded the warning threshold.If no action is taken and the temperature continue to increase, the system will s… | notification | - | .1.3.6.1.4.1.19746.2.0.6535 |
| unsupportedSystemType Description:
An unsupported system type has been detected and needs
to be modified or replaced.
Action:
Contact your contracted support provider or visit us online a… | notification | - | .1.3.6.1.4.1.19746.2.0.6536 |
| bMCHangShutdown Description:
While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational. This could mask serious problems such as overheating.
… | notification | - | .1.3.6.1.4.1.19746.2.0.6537 |
| expiredHostCertificate Description:
Communication using this certificate is vulnerable to disclosure.
Action:
Replace the host certificate with a valid certificate. | notification | - | .1.3.6.1.4.1.19746.2.0.6538 |
| sCSITGTInvalidRegistry Description:
A registry entry used in the SCSI Target system is invalid.
The SCSI Target services, including VTL, DD-BOOST FC and VDISK will be
inaccessible until this problem is… | notification | - | .1.3.6.1.4.1.19746.2.0.6539 |
| encryptionKeyExportFailed Description:
The automatic export of the encryption keys failed.
This could result in encrypted data being inaccessible.
Action:
Manually export the encryption keys. | notification | - | .1.3.6.1.4.1.19746.2.0.6540 |
| sSDEndOfLife Description:
The SSD has reached end of life and could fail at any time.
The system may shut down unexpectedly if the drive is not replaced.
Action:
Contact your cont… | notification | - | .1.3.6.1.4.1.19746.2.0.6541 |
| tapeReposition Description:
The tape volume was adjusted to the last consistent data position during
VTL recovery. Recent pending updates to the volume may have been discarded.
Actio… | notification | - | .1.3.6.1.4.1.19746.2.0.6542 |
| multipleDiskReadErrors Description:
There are too many disks reporting read errors in the same RAID group.
As each of these disks completes reconstruction it will be failed.
If the ongoing RAID reconst… | notification | - | .1.3.6.1.4.1.19746.2.0.6543 |
| missingCreplUnits Description:
The collection replication destination is not in a consistent state and will not be usable until matching retention units are added to the destination.
Ac… | notification | - | .1.3.6.1.4.1.19746.2.0.6544 |
| nvramBattEndOfLife Description:
The remote battery for NVRAM us currently usable but is approaching the end of its life.
If the battery is not replaced before it reaches end of its life, the filesy… | notification | - | .1.3.6.1.4.1.19746.2.0.6545 |
| fileSystemFailedAlarm deprecated Meaning: The File System process on the DDR has had a serious problem and has had
to restart.
What to do: check the system logs for conditions that may be triggering the failure.
… | notification | - | .1.3.6.1.4.1.19746.2.0.7 |
| bMCFailure Description:
BMC is unresponsive or unable to access some required information. This may be corrected by a BMC reset procedure. If the condition is serious, the file system will … | notification | - | .1.3.6.1.4.1.19746.2.0.7000 |
| unsupportedDriveModel Description:
This system only supports certain drive models.
The unsupported drives are unusable and must be replaced for proper system operation.
Action:
Identify an… | notification | - | .1.3.6.1.4.1.19746.2.0.7001 |
| driveMixType Description:
Mixing drive types within an enclosure is not supported and may cause unexpected system behavior.
Action:
Ensure that all drives within the enclosure are… | notification | - | .1.3.6.1.4.1.19746.2.0.7002 |
| sMSUnresponsive Description:
The System Management Service has reached the maximum number of concurrent
requests and has been unresponsive for over five minutes. This may indicate
a serious co… | notification | - | .1.3.6.1.4.1.19746.2.0.7500 |
| nISCommFailure Description:
Unable to query information from the NIS server.
This could be a network problem or an authentication failure with the NIS server.
This could prevent NIS servers fr… | notification | - | .1.3.6.1.4.1.19746.2.0.7501 |
| unsupportedHardwareConfig Description:
Unsupported virtual machine hardware configuration was detected.
This configuration may cause unexpected behavior.
Action:
Fix the hardware configurati… | notification | - | .1.3.6.1.4.1.19746.2.0.7502 |
| unsupportedVirtualCPU Description:
The current number of CPU sockets and cores in the
virtual machine configuration is not valid for the
current storage capacity. The file system will not
be enable… | notification | - | .1.3.6.1.4.1.19746.2.0.7503 |
| dNSUnresponsive Description:
No DNS servers responded to a DNS query. This may be caused by a network failure or a DNS server problem.
System functions that require name address resolution will … | notification | - | .1.3.6.1.4.1.19746.2.0.7504 |
| nTPDFailed Description:
Network Time Protocol (NTP) daemon is not running. NTP daemon has detected a
time difference between this system and the configured network time server
(drift) great… | notification | - | .1.3.6.1.4.1.19746.2.0.7505 |
| invalidEnclosureTopology Description:
The cables connecting enclosures to the controller are not installed correctly. This can cause unpredictable system behavior. Recable the enclosures immediately.
… | notification | - | .1.3.6.1.4.1.19746.2.0.7506 |
| diskPathSpeedDegraded Description:
SAS connection speed is degraded and could reduce disk performance.
Action:
Check cable seating and replace if needed.
If the problem persists, contact y… | notification | - | .1.3.6.1.4.1.19746.2.0.7507 |
| targetDriverPortOffline Description:
No connection is detected on the Fibre Channel Port.
Action:
If this port is not in use, please disable it. If port is being
used, please restore Fibre … | notification | - | .1.3.6.1.4.1.19746.2.0.7508 |
| targetDriverPortOnline Description:
Fibre Channel Port is online.
Action:
No action required | notification | - | .1.3.6.1.4.1.19746.2.0.7509 |
| targetDriverPortCore Description:
An error occurred on the Fibre Channel Port that resulted in a HBA core.
Action:
Contact your contracted support provider or visit us online at https://… | notification | - | .1.3.6.1.4.1.19746.2.0.7510 |
| targetDriverPortMultipleCore Description:
An error occurred on the Fibre Channel Port that caused multiple HBA core attempts. The Fibre Channel Port is disabled.
Action:
Contact your contracted … | notification | - | .1.3.6.1.4.1.19746.2.0.7511 |
| targetDriverPortFWLoadFailed Description:
The Fibre Channel Port is unable to load required firmware. The Fibre Channel Port is disabled.
Action:
Contact your contracted support provider or visi… | notification | - | .1.3.6.1.4.1.19746.2.0.7512 |
| targetDriverPortUnreadable Description:
Unable to access one or more resources on the HBA. The Fibre Channel Port is disabled.
Action:
Contact contact your contracted support provider or visit… | notification | - | .1.3.6.1.4.1.19746.2.0.7513 |
| targetDriverPortTooManyOsc Description:
The system has detected a Fibre Channel Port has been transitioning
between online and offline too frequently. This may cause disruption in i/o.
Action:
… | notification | - | .1.3.6.1.4.1.19746.2.0.7514 |
| insufficientSpaceForEncryption Description:
Additional space is needed on the archive tier to encrypt the existing data.
Free space up to 1% of data size may be required.
Un-encrypted data will not get encrypt… | notification | - | .1.3.6.1.4.1.19746.2.0.7515 |
| dDFSRequiresReboot Description:
File system was unable to start because an abnormal internal
condition was detected.
Action:
Reboot the system. If problem persists, contact your contrac… | notification | - | .1.3.6.1.4.1.19746.2.0.7516 |
| storageUnitStreamSoftLimit Description:
Stream soft limit quota for this storage-unit and type of stream has been exceeded.
Crossing this limit may cause reduced performance as the system hard limits are r… | notification | - | .1.3.6.1.4.1.19746.2.0.7517 |
| spaceReclSuspended Description:
Archive space reclamation has suspended due to the specified error.
Space will not be reclaimed in the archive tier until the error condition is resolved and space r… | notification | - | .1.3.6.1.4.1.19746.2.0.7518 |
| metadataWarningThreshold Description:
Large amount of metadata has been created by the filesystem.
Continuing without cleaning would cause the filesystem to enter into read-only mode.
Action: … | notification | - | .1.3.6.1.4.1.19746.2.0.7519 |
| mtreeCascadeNeedResync Description:
This Mtree is now a cascaded source. Since this mtree already has data, this replication context requires a resync to proceed.
Action:
To re-establish… | notification | - | .1.3.6.1.4.1.19746.2.0.7520 |
| filesystemCorruption Description:
Filesystem processing detected some corruption.
This may be isolated to a single file or multiple files,
preventing you from reading the corrupted files.
If a syst… | notification | - | .1.3.6.1.4.1.19746.2.0.7521 |
| missingTierStorage Description:
Critical storage resources are unavailable, preventing the tier from functioning.
Action:
Verify all storage is functional and configured correctly.
If t… | notification | - | .1.3.6.1.4.1.19746.2.0.7522 |
| spaceReclUnitError Description:
Space reclamation encountered an error and cannot proceed on the specified archive unit.
If you have more than one archive unit, space reclamation will continue on … | notification | - | .1.3.6.1.4.1.19746.2.0.7523 |
| bMCFailureSysBBU Description:
BMC is unresponsive or unable to access some required information. This may be corrected by a BMC reset procedure. If the condition is serious, the file system will … | notification | - | .1.3.6.1.4.1.19746.2.0.7524 |
| fileSpaceMaintenanceAlarm deprecated Meaning: DDVAR File System Resource Space is running low for system maintenance activities. The
system may not have enough space for the routine system activities to run without … | notification | - | .1.3.6.1.4.1.19746.2.0.8 |
| licenseExpiring Description:
The temporary license indicated is about to expire. The function provided by this license will cease to operate.
Action:
Contact your [account team] to p… | notification | - | .1.3.6.1.4.1.19746.2.0.8001 |
| licenseExpired Description:
The temporary license indicated has expired. The function provided by this license has stopped operating.
Action:
Contact your [account team] to purchase… | notification | - | .1.3.6.1.4.1.19746.2.0.8002 |
| fileSpacePreWarningAlarm deprecated Meaning: A File System Resource space is 80-85% utilized. While not critical, the space usage
should be monitored. The index value of the alarm indicates the file system index t… | notification | - | .1.3.6.1.4.1.19746.2.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| diskSerialNumber Serial Number of the disk | column | DiskSerialNumberTC | .1.3.6.1.4.1.19746.1.6.1.1.1.6 |