cpqDaSparePercentRebuild
CPQIDA-MIB ·
.1.3.6.1.4.1.232.3.2.4.1.1.11
Object
Drive Array Spare Percent Rebuild.
If the spare status is building(5), then this is percent
complete of of the rebuild.
The data contained on the failed physical drive must be
reconstructed from the fault tolerance data and copied to the
spare so that the spare can function in place of the failed drive.
When the number reaches one hundred (100), the building process
is complete and the spare has replaced the physical drive.
If the value cannot be determined or a rebuild is not active,
the value is set to 4,294,967,295.
Context
- MIB
- CPQIDA-MIB
- OID
.1.3.6.1.4.1.232.3.2.4.1.1.11- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqDaSpareEntry
- Table
- cpqDaSpareTable
- Siblings
- 11
Syntax
RFC1155-SMIGauge
- Source
- RFC1155-SMIGauge
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqDaSpareCntlrIndex mandatory Drive Array Spare Controller Index.
This index maps the spare drive back to the controller to which
it is attached. The value of this index is the same as the one
… | column | Integer32 | .1.3.6.1.4.1.232.3.2.4.1.1.1 |
| cpqDaSpareReplacedDrvBay mandatory Spare Replaced Drive Bay.
If the spare status is active(6) or building(5), then this
has the physical drive bay number of the replaced drive.
If the value cannot be… | column | Integer32 | .1.3.6.1.4.1.232.3.2.4.1.1.10 |
| cpqDaSpareLocationString mandatory Spare Drive Location String.
This string describes the location of the drive in relation to
the controller. If the location string cannot be determined,
the agent … | column | OctetString | .1.3.6.1.4.1.232.3.2.4.1.1.12 |
| cpqDaSparePhyDrvIndex mandatory Drive Array Spare Physical Drive Index.
This index maps the spare to the physical drive it represents.
The value of this index is the same as the one used with the
… | column | Integer32 | .1.3.6.1.4.1.232.3.2.4.1.1.2 |
| cpqDaSpareStatus mandatory Spare Status.
This shows the status of the on-line spare drive.
The following values are valid for the spare status:
Failed (3)
The … | column | Enumeration | .1.3.6.1.4.1.232.3.2.4.1.1.3 |
| cpqDaSpareReplacedDrv mandatory Spare Replaced Drive.
If the spare status is active(6) or building(5), then this
has the physical drive number of the replaced drive. Otherwise
a value of -1 will … | column | Integer32 | .1.3.6.1.4.1.232.3.2.4.1.1.4 |
| cpqDaSpareRebuildBlks obsolete Drive Array Spare Number Of Rebuild Blocks Left.
If the spare status is building(5), then this is the number of
blocks left to rebuild before completion.
… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.3.2.4.1.1.5 |
| cpqDaSpareCondition mandatory The Spare Drive condition.
This value represents the overall condition of this spare drive
and any associated physical drives. | column | Enumeration | .1.3.6.1.4.1.232.3.2.4.1.1.6 |
| cpqDaSpareBusNumber mandatory Spare Drive SCSI Bus Number.
The bus number indicates to which SCSI bus this spare drive
is attached. The first instance is one and increments for
each SCSI bus on… | column | Integer32 | .1.3.6.1.4.1.232.3.2.4.1.1.7 |
| cpqDaSpareBay mandatory Spare Drive Bay Location.
This value matches the bay location where the physical drive has
been installed. For a SCSI drive, this is the SCSI ID of the
drive. | column | Integer32 | .1.3.6.1.4.1.232.3.2.4.1.1.8 |
| cpqDaSpareReplacedDrvBusNumber mandatory Spare Replaced Drive Bus Number.
If the spare status is active(6) or building(5), then this
has the physical drive bus number of the replaced drive.
If the value ca… | column | Integer32 | .1.3.6.1.4.1.232.3.2.4.1.1.9 |