cpqFcaPhyDrvSpinupTime

CPQFCA-MIB · .1.3.6.1.4.1.232.16.2.5.1.1.21

Object

column mandatory Integer32
Spin up Time in tenths of seconds.
              
This is the time it takes for a physical drive to spin up to full
speed.
              
Disks require time to gain momentum and reach operating speed. As
cars are tested to go from 0 mph to 60 mph in x number of seconds,
drive manufacturers have preset expectations for the time it takes
the drive to spin to full speed. Drives that do not meet these
expectations may have problems.
              
The value may be zero (0) under one of the following conditions:
              
*  If you are monitoring a physical drive that is part of the
   monitored system`s internal drive array storage, and you use a
   warm boot to reset the monitored system. During a warm boot,
   the drives continue to spin.
              
*  If you are monitoring a physical drive in an ProLiant Storage
   System storage and you reset the array but not the ProLiant
   Storage System.
              
If the value cannot be determined, -1 is returned.

Context

MIB
CPQFCA-MIB
OID
.1.3.6.1.4.1.232.16.2.5.1.1.21
Type
column
Access
readonly
Status
mandatory
Parent
cpqFcaPhyDrvEntry
Table
cpqFcaPhyDrvTable
Siblings
57

Syntax

Integer32
Source
COPS-PR-SPPIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects