cpqFcaPhyDrvNotReadyErrs

CPQFCA-MIB · .1.3.6.1.4.1.232.16.2.5.1.1.29

Object

column mandatory RFC1155-SMICounter
Drive Not Ready Errors.
              
The number of times the physical drive failed after the spin up
command was issued during the reference time (phyDrvRefTime).
When the spin up command was issued, the drive failed to reach
its ready state.  If the current value is zero, the drive has
not failed.  If the current value is greater than zero, at
least one failure occurred.
              
This error could be caused because the physical drive has failed
to spin.
              
If you suspect a problem:
              
1.  Check the cables connecting the drive to ensure that they
    are intact.
              
2.  If the cables are properly connected, run diagnostics to
    verify that a problem exists.
              
If the value cannot be determined, 4,294,967,295 is
returned.