cpqFcaPhyDrvCurrentSpeed
CPQFCA-MIB ·
.1.3.6.1.4.1.232.16.2.5.1.1.46
Object
column
mandatory
Enumeration
Physical Drive Current Data Transfer Speed.
The following values are defined:
other(1)
The agent is unable to determine the current negotiated data
transfer speed for this drive.
asynchronous(2)
The negotiated data transfer speed for this drive is
asynchronous.
fast(3)
The negotiated data transfer speed for this drive is 10 million
transfers per second).
ultra(4)
The negotiated data transfer speed for this drive is 20 million
transfers per second.
ultra2(5)
The negotiated data transfer speed for this drive is 40 million
transfers per second.
ultra3(6)
The negotiated data transfer speed for this drive is 80 million
transfers per second.
ultra320(7)
The negotiated data transfer speed for this drive is 160
million transfers per second.
Context
- MIB
- CPQFCA-MIB
- OID
.1.3.6.1.4.1.232.16.2.5.1.1.46- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqFcaPhyDrvEntry
- Table
- cpqFcaPhyDrvTable
- Siblings
- 57
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | asynchronous |
3 | fast |
4 | ultra |
5 | ultra2 |
6 | ultra3 |
7 | ultra320 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqFcaPhyDrvBoxIndex mandatory External Array Physical Drive Storage Box Index.
The storage box index indicates which storage box this physical
drive is in. | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.1 |
| cpqFcaPhyDrvReads mandatory External Array Physical Drive Sectors Read (low).
The phyDrvHReads and the phyDrvReads together shows
the total number of sectors read from the physical disk drive
… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.10 |
| cpqFcaPhyDrvHWrites mandatory Sectors Written (high).
The phyDrvHWrites and the phyDrvWrites together shows the
total number of sectors written to the physical disk drive
during the reference ho… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.11 |
| cpqFcaPhyDrvWrites mandatory Sectors Written (low).
The phyDrvHWrites and the phyDrvWrites together
shows the total number of sectors written to the physical
disk drive during the reference hou… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.12 |
| cpqFcaPhyDrvHSeeks mandatory Total Seeks (high).
The phyDrvHSeeks and the phyDrvSeeks together shows the total
number of seek operations performed by the physical disk drive
during the referenc… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.13 |
| cpqFcaPhyDrvSeeks mandatory Total Seeks (low).
The phyDrvHSeeks and the phyDrvSeeks together shows the total
number of seek operations performed by the physical disk drive
during the reference… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.14 |
| cpqFcaPhyDrvHardReadErrs mandatory Hard Read Errors.
This shows the number of read errors that have occurred on a
drive that could not be recovered by a physical drive`s Error
Correction Code (ECC) a… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.15 |
| cpqFcaPhyDrvRecvReadErrs mandatory Recovered Read Errors.
This shows the number of read errors corrected through physical
drive retries during the reference time (phyDrvRefTime).
Over … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.16 |
| cpqFcaPhyDrvHardWriteErrs mandatory Hard Write Errors.
This shows the number of write errors that could not be recovered
by a physical drive during the reference time (phyDrvRefTime).
O… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.17 |
| cpqFcaPhyDrvRecvWriteErrs mandatory Recovered Write Errors.
This shows the number of write errors corrected through physical
drive retries or recovered by a physical drive during the
reference time (p… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.18 |
| cpqFcaPhyDrvHSeekErrs mandatory Seek Errors (High).
The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
total number of times that the physical disk drive detected a
seek error during th… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.19 |
| cpqFcaPhyDrvIndex mandatory External Array Physical Drive Index.
This index is used for selecting the physical drive table entry.
This number, along with the cpqFcaPhyDrvBoxIndex uniquely
iden… | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.2 |
| cpqFcaPhyDrvSeekErrs mandatory Seek Errors (low).
The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
total number of times that the physical disk drive detected a
seek error during the reference hour… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.20 |
| cpqFcaPhyDrvSpinupTime mandatory Spin up Time in tenths of seconds.
This is the time it takes for a physical drive to spin up to full
speed.
Disks require time to gain momentum and r… | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.21 |
| cpqFcaPhyDrvFunctTest1 obsolete Functional Test 1.
This provides information about a series of tests that indicate
how well a physical drive works. These tests compare the way the
physical drive c… | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.16.2.5.1.1.22 |
| cpqFcaPhyDrvFunctTest2 obsolete Functional Test 2.
This provides information about a series of tests that indicate
how well a physical drive works. These tests compare the way the
physical drive c… | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.16.2.5.1.1.23 |
| cpqFcaPhyDrvFunctTest3 obsolete Functional Test 3.
This provides information about a series of tests that indicate
how well a physical drive works. These tests compare the way the
physical drive c… | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.16.2.5.1.1.24 |
| cpqFcaPhyDrvOtherTimeouts mandatory Other Timeouts.
The number of times that a physical drive did not respond with an
interrupt within a controller-defined period of time after a
command had been issu… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.25 |
| cpqFcaPhyDrvBadRecvReads mandatory Recovery Failed (Bad) Read Error.
The number of times a read error occurred while performing
Automatic Data Recovery from this physical drive to another
drive durin… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.26 |
| cpqFcaPhyDrvBadRecvWrites mandatory Recovery Failed (Bad) Write Error.
The number of times a write error occurred while performing
Automatic Data Recovery from another drive to this physical
drive dur… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.27 |
| cpqFcaPhyDrvFormatErrs mandatory Format Error.
The number of times a format operation failed when the controller
attempted to remap a bad sector during the reference time
(phyDrvRefTime). Zero ind… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.28 |
| cpqFcaPhyDrvNotReadyErrs mandatory Drive Not Ready Errors.
The number of times the physical drive failed after the spin up
command was issued during the reference time (phyDrvRefTime).
When the spin … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.29 |
| cpqFcaPhyDrvModel mandatory External Array Physical Drive Model.
This is a text description of the physical drive. The text that
appears depends upon who manufactured the drive and the drive
… | column | OctetString | .1.3.6.1.4.1.232.16.2.5.1.1.3 |
| cpqFcaPhyDrvHasMonInfo mandatory Physical Drive Has Monitor Information.
All of the physical disk table fields except for the physical
disk status (phyDrvStatus) and the bay location
(phyDrvBayLoca… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.30 |
| cpqFcaPhyDrvCondition mandatory The condition of the device.
This value represents the overall condition of this physical
drive. | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.31 |
| cpqFcaPhyDrvHotPlugs mandatory Physical Drive Hot Plug Count.
This value indicates the number of times this physical drive
was hot-plugged (removed) from a storage system.
If the v… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.32 |
| cpqFcaPhyDrvMediaErrs mandatory Physical Drive Media Failure Count.
This value indicates the number of times this physical drive
was failed due to unrecoverable media errors.
If the… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.33 |
| cpqFcaPhyDrvHardwareErrs mandatory Physical Drive Hardware Error Count.
This value indicates the number of times this physical drive
returned a bad hardware status. The drive may be failed if
retries… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.34 |
| cpqFcaPhyDrvAbortedCmds mandatory Physical Drive Aborted Command Failures.
This value indicates the number of times this physical drive
was failed due to aborted commands that could not be retried
s… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.35 |
| cpqFcaPhyDrvSpinUpErrs mandatory Physical Drive Spin-Up Failure Count.
This value indicates the number of times this physical drive
was failed due to a failure of a spin-up command.
… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.36 |
| cpqFcaPhyDrvBadTargetErrs mandatory Physical Drive Bad Target Count.
This value indicates the number of times this physical drive
performed some action that did not conform to the SCSI-2 bus
protocol.… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.37 |
| cpqFcaPhyDrvSize mandatory Physical Drive Size in MB.
This is the size of the physical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manu… | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.38 |
| cpqFcaPhyDrvBusFaults mandatory Physical Drive Bus Fault Count.
This value indicates the number of times that a bus fault was
detected for the drive by the controller.
If the value … | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.39 |
| cpqFcaPhyDrvFWRev mandatory External Array Physical Drive Firmware Revision.
This shows the physical drive firmware revision number. | column | OctetString | .1.3.6.1.4.1.232.16.2.5.1.1.4 |
| cpqFcaPhyDrvHotPlug mandatory Physical Drive Hot Plug Support Status.
The following values are defined:
other(1)
The Insight Agent is unable to determine if this drive
support… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.40 |
| cpqFcaPhyDrvPlacement mandatory Physical Drive Placement.
The following values are defined:
other(1)
The agent is unable to determine if the drive is internal or
external to the… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.41 |
| cpqFcaPhyDrvBusNumber mandatory Physical Drive SCSI Bus Number.
The bus number indicates to which SCSI bus this physical
drive is attached. The first instance is one and increments
for each SCSI … | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.42 |
| cpqFcaPhyDrvSerialNum mandatory Physical Drive Serial Number.
This is the serial number assigned to the physical drive.
This value is based upon the serial number as returned by the
SCSI inquiry c… | column | OctetString | .1.3.6.1.4.1.232.16.2.5.1.1.43 |
| cpqFcaPhyDrvPreFailMonitoring mandatory Physical Drive Predictive Failure Monitoring.
The following values are defined:
other(1)
The agent is unable to determine if the drive supports
p… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.44 |
| cpqFcaPhyDrvCurrentWidth mandatory Physical Drive Current Width.
The following values are defined:
other(1)
The agent is unable to determine the current negotiated data
transfer wi… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.45 |
| cpqFcaPhyDrvFailureCode mandatory Physical Drive Failure Code.
This value is the drive failure reason code returned by the
array firmware. It is valid only when the drive is failed.
If the drive is… | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.47 |
| cpqFcaPhyDrvBlinkTime mandatory Physical Drive LED Blink Time.
This value is the amount of time remaining for the drive LEDs to
blink in tenths of seconds. A value of zero means the drive
LEDs ar… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.48 |
| cpqFcaPhyDrvSmartStatus mandatory Physical Drive S.M.A.R.T Status.
The following values are defined:
other(1)
The agent is unable to determine if the status of S.M.A.R.T
predictiv… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.49 |
| cpqFcaPhyDrvBay mandatory External Array Physical Drive Bay Location.
This value matches the bay location where the physical drive has
been installed. Each bay is labeled with a separate nu… | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.5 |
| cpqFcaPhyDrvRotationalSpeed mandatory Physical Drive Rotational Speed.
The following values are defined:
other(1)
The agent is unable to determine the rotational speed for
this drive.… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.50 |
| cpqFcaPhyDrvType mandatory Physical Drive Type.
The following values are defined:
other(1)
The agent is unable to determine the type for this drive.
parallelSc… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.51 |
| cpqFcaPhyDrvSataVersion mandatory Physical Drive SATA Version.
The following values are defined:
other(1)
The agent is unable to determine the SATA version for this
drive or it is… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.52 |
| cpqFcaPhyDrvBoxConnector mandatory Physical Drive Box Connector.
This is the box connector to which the drive is ultimately
attached. If the box connector cannot be determined, the agent
will return… | column | OctetString | .1.3.6.1.4.1.232.16.2.5.1.1.53 |
| cpqFcaPhyDrvBoxOnConnector mandatory Physical Drive Box on Connector.
The box on connector indicates to which box instance this
physical drive belongs. The instances start at one and increment for
eac… | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.54 |
| cpqFcaPhyDrvLocationString mandatory Physical Drive Location String.
This string describes the location of the drive in relation to
the storage box. If the location string cannot be determined,
the ag… | column | OctetString | .1.3.6.1.4.1.232.16.2.5.1.1.55 |
| cpqFcaPhyDrvNegotiatedLinkRate mandatory Physical Drive Negotiated Link Rate.
The following values are defined:
other(1)
The agent is unable to determine the negotiated link rate
this dr… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.56 |
| cpqFcaPhyDrvPhyCount mandatory Physical Drive PHY Count.
This value indicates how many PHYs exist on a SAS or SATA disk
drive. If the value cannot be determined or does not apply,
-1 is returne… | column | Integer32 | .1.3.6.1.4.1.232.16.2.5.1.1.57 |
| cpqFcaPhyDrvUnsupportedDrive mandatory Physical Drive Unsupported Drive.
The following values are defined:
other(1)
The agent is unable to determine the value for this drive.
… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.58 |
| cpqFcaPhyDrvStatus mandatory External Array Physical Drive Status.
This shows the status of the physical drive.
The following values are valid for the physical drive status:
… | column | Enumeration | .1.3.6.1.4.1.232.16.2.5.1.1.6 |
| cpqFcaPhyDrvUsedReallocs mandatory External Array Physical Drive Used Reallocated Sectors.
This shows the number of sectors of the reallocation area that
have been used by the physical drive.
… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.7 |
| cpqFcaPhyDrvRefHours mandatory External Array Reference Time in hours.
This shows the total number of hours that a physical drive has
been spinning since the drive was stamped. The drive will ha… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.8 |
| cpqFcaPhyDrvHReads mandatory External Array Physical Drive Sectors Read (high).
The phyDrvHReads and the phyDrvReads together shows the total
number of sectors read from the physical disk drive… | column | RFC1155-SMICounter | .1.3.6.1.4.1.232.16.2.5.1.1.9 |