bladeDetailsPowerSaverMode
CME-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6
Object
column
mandatory
r/w
Enumeration
When enabled, the static low power saver mode allows the blade to selectively
alter its operating voltage and frequency to reduce power consumption.
This feature is not available on all blade types. Please refer to the blade documentation for details.
If a blade does not support the static low power saver mode, this object will return notApplicable (255).
Under certain rare circumstances, the enabling of the static low power saver mode
may not complete successfully due to interactions with other
blade functions, such as BIOS. Therefore, it is highly recommended that
the user perform a GET of this object after performing a SET, in order
to verify the completion of the intended operation.
NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled.
Context
- MIB
- CME-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- bladeDetailsEntry
- Table
- bladeDetailsTable
- Siblings
- 11
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | disable |
1 | enable |
255 | notApplicable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| bladeDetailsIndex mandatory Blade Module Details Table Index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1 |
| bladeDetailsPcapMin mandatory Blade Module Details Table power capping Minimum value in watts.
The blade must support the advanced power management feature.
If the value of Pcap Min is 'notAppli… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.10 |
| bladeDetailsPcapGuaranteedMin mandatory Blade Module Details Table power capping Guaranteed Minimum value in watts.
The blade must support the advanced power management feature.
If the value of Pcap Guara… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.11 |
| bladeDetailsPcapMax mandatory Blade Module Details Table power capping Maximum value in watts.
The blade must support the advanced power management feature.
If the value is '<max1> Watts,<max2> … | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.12 |
| bladeDetailsId mandatory Blade Module Details Table Blade Id. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2 |
| bladeDetailsMaxPowerConfig mandatory Blade Module Details Table Maximum Power Configuration.
Allow the user to set the maximum power that can be used by the blade. This
function is also known as power capping.
Blade … | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3 |
| bladeDetailsEffectiveClockRate mandatory Blade Module Details Table Effective CPU Clock Rate applies to DPM
blades only. It displays processor's effective clock rate based
on sample interval. Note that some blades do n… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4 |
| bladeDetailsMaximumClockRate mandatory Blade Module Details Table Maximum CPU Clock Rate applies to DPM
blades only. It displays processor's maximum clock rate based
on sample interval. Note that some blades do not m… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5 |
| bladeDetailsDynamicPowerSaver mandatory When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade
to be controlled based on how busy the CPU is. This feature is not available on all bl… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7 |
| bladeDetailsDynamicPowerFavorPerformanceOverPower mandatory When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the
system past its nominal CPU frequency when CPU and memory utilization impl… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8 |
| bladeDetailsPowerControl mandatory This object is used to get or set the power control setting on a blade.
If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned.
… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9 |