cswStackMemberToBeReloadedForUpgrade
CISCO-STACKWISE-MIB ·
.1.3.6.1.4.1.9.9.500.0.0.23
Object
notification
This notification is generated when a member is to be reloaded for upgrade.
Context
- MIB
- CISCO-STACKWISE-MIB
- OID
.1.3.6.1.4.1.9.9.500.0.0.23- Type
- notification
- Status
- current
- Parent
- cswMIBNotifications
- Siblings
- 22
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cswStackPortChange This notification is generated when the state
of a stack port has changed. | notification | - | .1.3.6.1.4.1.9.9.500.0.0.1 |
| cswStackPowerInvalidTopology This notification is generated when an invalid stack power
topology is discovered by a switch. cswSwitchNumCurrent
indicates the switch number of the system where the invalid
topo… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.10 |
| cscwStackPowerBudgetWarrning This notification is generated when the switch power budget is
more than 1000W above its power supplies rated power output.
cswSwitchNumCurrent indicates the switch number of the … | notification | - | .1.3.6.1.4.1.9.9.500.0.0.11 |
| cswStackPowerInvalidInputCurrent This notification is generated when the input current in the
stack power cable is over the limit of the threshold retrieved
by the agent through cswStackPowerPortOverCurrentThresh… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.12 |
| cswStackPowerInvalidOutputCurrent This notification is generated when the output current in the
stack power cable is over the limit of the threshold retrieved
by the agent through cswStackPowerPortOverCurrentThres… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.13 |
| cswStackPowerUnderBudget This notification is generated when the switch's budget is less
than maximum possible switch power consumption.
cswSwitchNumCurrent indicates the switch number of the system
that … | notification | - | .1.3.6.1.4.1.9.9.500.0.0.14 |
| cswStackPowerUnbalancedPowerSupplies This notification is generated when the switch has no power
supply but another switch in the same stack has more than one
power supplies. cswStackPowerName specifies a unique name… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.15 |
| cswStackPowerInsufficientPower This notification is generated when the switch's power stack
does not have enough power to bring up all the switches in the
power stack. cswStackPowerName specifies a unique name … | notification | - | .1.3.6.1.4.1.9.9.500.0.0.16 |
| cswStackPowerPriorityConflict This notification is generated when the switch's power
priorities are conflicting with power priorities of another
switch in the same power stack. cswStackPowerPortName specifies
… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.17 |
| cswStackPowerUnderVoltage This notification is generated when the switch had an under
voltage condition on last boot up. cswSwitchNumCurrent
indicates the switch number of the system that was forced
down w… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.18 |
| cswStackPowerGLS This notification is generated when the switch had to shed
loads based on a sustained over load (SOC) condition.
cswSwitchNumCurrent indicates the switch number of the system
that… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.19 |
| cswStackNewMaster This notification is generated when a new master has been
elected. The notification will contain the cswSwitchNumCurrent
object to indicate the new master ID. | notification | - | .1.3.6.1.4.1.9.9.500.0.0.2 |
| cswStackPowerILS This notification is generated when the switch had to shed
loads based on power supply fail condition. cswSwitchNumCurrent
indicates the switch number of the system that goes thro… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.20 |
| cswStackPowerSRLS This notification is generated when the switch had to shed
loads based on loss of a system in ring topology.
cswSwitchNumCurrent indicates the switch number of the system
that det… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.21 |
| cswStackPowerSSLS This notification is generated when the switch had to shed
loads based on loss of a system in star topology.
cswSwitchNumCurrent indicates the switch number of the system
that det… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.22 |
| cswStackMismatch This notification is generated when a new member attempt
to join the stack but was denied due to a mismatch. The
cswSwitchState object will indicate the type of mismatch. | notification | - | .1.3.6.1.4.1.9.9.500.0.0.3 |
| cswStackRingRedundant This notification is generated when the redundancy of the
ring has changed. | notification | - | .1.3.6.1.4.1.9.9.500.0.0.4 |
| cswStackNewMember This notification is generated when a new member joins the
stack. | notification | - | .1.3.6.1.4.1.9.9.500.0.0.5 |
| cswStackMemberRemoved This notification is generated when a member is removed
from the stack. | notification | - | .1.3.6.1.4.1.9.9.500.0.0.6 |
| cswStackPowerPortLinkStatusChanged This notification is generated when the link status of a stack
power port is changed from up to down or down to up. This
notification is for informational purposes only and no act… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.7 |
| cswStackPowerPortOperStatusChanged This notification is generated when the operational status of a
stack power port is changed from enabled to disabled or from
disabled to enabled. This notification is for informat… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.8 |
| cswStackPowerVersionMismatch This notification is generated when the major version of the
stack power protocol is different from the other members of the
power stack. Upon receiving this notification, the use… | notification | - | .1.3.6.1.4.1.9.9.500.0.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cswSwitchNumCurrent This object contains the current switch identification number.
This number should match any logical labeling on the switch.
For example, a switch whose interfaces are labeled
'int… | column | CswSwitchNumber | .1.3.6.1.4.1.9.9.500.1.2.1.1.1 |