protection
CAMBIUM-PTP800-MIB ·
.1.3.6.1.4.1.17713.8.25.1
Object
scalar
r/w
Enumeration
PTP 800 supports a 1+1 Hot Standby configuration where the wireless link is protected against hardware failure. This requires the installation of redundant equipment at each end of the wireless link including a secondary CMU and RFU. At a given end of the wireless link, only one CMU / RFU is Active at any one time, the neighbor CMU / RFU being Inactive. When a fault is detected on the Active CMU / RFU, the Active role will automatically switch to the Inactive CMU / RFU. To enable functionality associated with this feature, this attribute must be configured for a setting of 1+1.
Context
- MIB
- CAMBIUM-PTP800-MIB
- OID
.1.3.6.1.4.1.17713.8.25.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- protectionConfig
- Siblings
- 11
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | disabled |
1 | hotStandby1plus1 |
2 | hotStandby1plus1withRxDiversity |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fiberY One or both ends of a 1+1 Hot Standby system can be
connected to the network using an 'Optical-Y Splitter Kit
per end'. This end configuration provides a single fiber
interface… | scalar | Enumeration | .1.3.6.1.4.1.17713.8.25.12 |
| rxDiversityVlanTpid When Receive Diversity is enabled, the Inactive CMU
sends Rx Diversity Ethernet Frames to the Active CMU.
These Ethernet Frames must be VLAN tagged and this
attribute controls … | scalar | Enumeration | .1.3.6.1.4.1.17713.8.25.14 |
| rxDiversityVid When Receive Diversity is enabled, the Inactive CMU
sends Rx Diversity Ethernet Frames to the Active CMU.
These Ethernet Frames must be VLAN tagged and this
attribute controls … | scalar | Integer32 | .1.3.6.1.4.1.17713.8.25.15 |
| faultProtectionSwitching In a 1+1 Hot Standby configuration, protection switching
on detection of a fault can be enabled/disabled using
this attribute. | scalar | Enumeration | .1.3.6.1.4.1.17713.8.25.2 |
| primarySecondaryMode At a given end of a 1+1 Hot Standby configuration, one
CMU must be configured as Primary, the other CMU as
Secondary. When a Protected Link initialises with no
faults, the CMUs… | scalar | Enumeration | .1.3.6.1.4.1.17713.8.25.3 |
| numberOfAntennas This must be configured to match the number of antennas
installed at this end of the link. | scalar | Enumeration | .1.3.6.1.4.1.17713.8.25.4 |
| primaryRecovery At a given end of a 1+1 Hot Standby configuration, the
CMU configured as Primary is the preferred unit to take
the Active role. If the Primary Recovery attribute is set
to Enab… | scalar | Enumeration | .1.3.6.1.4.1.17713.8.25.5 |
| primaryRecoveryPeriod At a given end of a 1+1 Hot Standby configuration, the
CMU configured as Primary is the preferred unit to take
the Active role. If the Primary Recovery attribute is set
to Enab… | scalar | Integer32 | .1.3.6.1.4.1.17713.8.25.6 |
| requestedProtectionState In a 1+1 Hot Standby configuration, only one CMU / RFU
at a given end of the link is Active at any one time, the
neighbor CMU / RFU being Inactive. Use the Requested
Protection… | scalar | Enumeration | .1.3.6.1.4.1.17713.8.25.7 |
| antennaReceiveLevelDeltaThreshold At a given end of a 1+1 Hot Standby configuration, a CMU
will raise an alarm to the management system when the
measured receive level adjusted by antenna gain and
feeder loss i… | scalar | Integer32 | .1.3.6.1.4.1.17713.8.25.8 |
| antennaReceiveLevelMeasurementWindow At a given end of a 1+1 Hot Standby configuration, a CMU
will raise an alarm to the management system when the
measured receive level adjusted by antenna gain and
feeder loss i… | scalar | Integer32 | .1.3.6.1.4.1.17713.8.25.9 |