cadDownChannelLsredMinThresh

CADANT-CMTS-DOWNCHANNEL-MIB · .1.3.6.1.4.1.4998.1.1.15.2.2.7

Object

scalar r/w milliseconds Integer32
This parameter defines the start of the downstream latency
region where packets are randomly dropped.  This value must
be less than or equal to cadDownChannelLsredMaxThresh.

Context

MIB
CADANT-CMTS-DOWNCHANNEL-MIB
OID
.1.3.6.1.4.1.4998.1.1.15.2.2.7
Type
scalar
Access
readwrite
Status
current
Units
milliseconds
Parent
cadDownChannelParams
Siblings
9

Syntax

milliseconds Integer32

Values & Constraints

Object Constraints
range: 10-2000

Related Objects

Sibling Objects