powerDomain1Entry
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1
Object
row
mandatory
Fuel Gauge entry
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1- Type
- row
- Status
- mandatory
- Parent
- powerDomain1Table
- Table
- powerDomain1Table
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pd1Index mandatory Power Domain 1 Table Index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1 |
| pd1ModuleCPUDutyCycles mandatory Power Domain 1 Table Module CPUs Duty Cycles applies to blade
servers only. It displays the duty cycle for each CPU on the blade
as a percentage. Note that some blades do not re… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10 |
| pd1ModuleThrottle mandatory Power Domain 1 Table Module Throttle indicates whether the
server blade may be allowed to throttle or not.
When a 1200W or 1400W power module is installed in the domain
the power … | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11 |
| pd1ModulePowerCapabilities mandatory Power Domain 1 Table Module Power Capabilities.
staticPowerManagement: the module with the static worst
case power values.
fixedPowermanagement: the module with… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12 |
| pd1ModuleMeasuredOrStatic mandatory Power Domain 1 Table Module Measured Or Static. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13 |
| pd1BayNumber mandatory Power Domain 1 Table Bay Number.
The following Bay Number IDs are used in the BladeCenter:
notApplicable(1),
notApplicable(2),
blowerBay1(3),
blowerBay2(4),
managementModuleB… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2 |
| pd1BladePrimarySlot mandatory Power Domain 1 Table Blade Primary Slot can be useful
when a server blade spans multiple slots (e.g. double wide or
triple wide). For example if the blade is double wide and
is i… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3 |
| pd1ModuleStatus mandatory Power Domain 1 Table Module Throttle Status. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4 |
| pd1ModuleName mandatory Power Domain 1 Table Module Name. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5 |
| pd1ModuleState mandatory Power Domain 1 Table Module State. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6 |
| pd1ModuleAllocatedPowerCurrent mandatory Power Domain 1 Table Allocated Power Current indicates the current power
allocation for the module in Watts. When a 1200W or 1400W power module is
installed in the domain the powe… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7 |
| pd1ModuleAllocatedPowerMax mandatory Power Domain 1 Table Allocated Power Max indicates the maximum power
allocation for the module in Watts. It is indicative of the maximum
amount of power the module will consume i… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8 |
| pd1ModuleAllocatedPowerMin mandatory Power Domain 1 Table Allocated Power Min indicates the minumum power
allocation for the module in Watts. It is indicative of the minumum
power consumption of the component in the… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9 |