pd1BayNumber

BLADE-MIB · .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2

Object

column mandatory OctetString
Power Domain 1 Table Bay Number.
The following Bay Number IDs are used in the BladeCenter:
 notApplicable(1),
 notApplicable(2),
 blowerBay1(3),
 blowerBay2(4),
 managementModuleBay1(5),
 managementModuleBay2(6),
 switchModuleBay1(7),
 switchModuleBay2(8),
 switchModuleBay3(9),
 switchModuleBay4(10),
 serverBladeBay1(11),
 serverBladeBay2(12),
 serverBladeBay3(13),
 serverBladeBay4(14),
 serverBladeBay5(15),
 serverBladeBay6(16),
 notApplicable(17)
The following Bay Number IDs are used in the BladeCenter H:
 notApplicable(1),
 notApplicable(2),
 fanPackBay1(3),
 fanPackBay2(4),
 fanPackBay3(5),
 fanPackBay4(6),
 managementModuleBay1(7),
 managementModuleBay2(8),
 ioModuleBay1(9),
 ioModuleBay2(10),
 ioModuleBay3(11),
 ioModuleBay4(12),
 ioModuleBay7(13),
 ioModuleBay8(14),
 ioModuleBay9(15),
 ioModuleBay10(16),
 serverBladeBay1(17),
 serverBladeBay2(18),
 serverBladeBay3(19),
 serverBladeBay4(20),
 serverBladeBay5(21),
 serverBladeBay6(22),
 serverBladeBay7(23),
 notApplicable(24)
The following Bay Number IDs are used in the BladeCenter T:
 notApplicable(1),
 notApplicable(2),
 blowerBay1(3),
 blowerBay2(4),
 blowerBay3(5) (if Power Domain 2 is not available),
 blowerBay4(6) (if Power Domain 2 is not available),
 managementModuleBay1(7),
 managementModuleBay2(8),
 switchModuleBay1(9),
 switchModuleBay2(10),
 switchModuleBay3(11),
 switchModuleBay4(12),
 serverBladeBay1(13),
 serverBladeBay2(14),
 serverBladeBay3(15),
 serverBladeBay4(16),
 notApplicable(17)
The following Bay Number IDs are used in the BladeCenter HT:
 notApplicable(1),
 mediatrayBay1(2),
 mediatrayBay2(3),
 fanPackBay1(4),
 fanPackBay2(5),
 fanPackBay3(6),
 fanPackBay4(7),
 blowerBay1(8),
 blowerBay2(9),
 blowerBay3(10),
 blowerBay4(11),
 networkclockBay1(12),
 networkclockBay2(13),
 midplaneelectroBay1(14),
 midplaneelectroBay2(15),
 notApplicable(16),
 managementModuleBay1(17),
 managementModuleBay2(18),
 ioModuleBay1(19),
 ioModuleBay2(20),
 ioModuleBay3(21),
 ioModuleBay4(22),
 serverBladeBay1(23),
 serverBladeBay2(24),
 serverBladeBay3(25),
 serverBladeBay4(26),
 serverBladeBay5(27),
 serverBladeBay6(28),
 notApplicable(29)
The following Bay Number IDs are used in the BladeCenter S:
 notApplicable(1),
 notApplicable(2),
 fanPackBay1(3),
 fanPackBay2(4),
 fanPackBay3(5),
 fanPackBay4(6),
 blowerBay1(7),
 blowerBay2(8),
 blowerBay3(9),
 blowerBay4(10),
 storageModuleBay1(11),
 storageModuleBay2(12),
 managementModuleBay(13),
 ioModuleBay1(14),
 ioModuleBay2(15),
 ioModuleBay3(16),
 ioModuleBay4(17),
 serverBladeBay1(18),
 serverBladeBay2(19),
 serverBladeBay3(20),
 serverBladeBay4(21),
 serverBladeBay5(22),
 serverBladeBay6(23),
 notApplicable(24)

Context

MIB
BLADE-MIB
OID
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2
Type
column
Access
readonly
Status
mandatory
Parent
powerDomain1Entry
Table
powerDomain1Table
Siblings
12

Syntax

OctetString

Values & Constraints

No enumerated values or constraints recorded.

Related Objects