pd1BayNumber
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2
Object
column
mandatory
OctetString
Power Domain 1 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), managementModuleBay1(5), managementModuleBay2(6), switchModuleBay1(7), switchModuleBay2(8), switchModuleBay3(9), switchModuleBay4(10), serverBladeBay1(11), serverBladeBay2(12), serverBladeBay3(13), serverBladeBay4(14), serverBladeBay5(15), serverBladeBay6(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay1(17), serverBladeBay2(18), serverBladeBay3(19), serverBladeBay4(20), serverBladeBay5(21), serverBladeBay6(22), serverBladeBay7(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), blowerBay3(5) (if Power Domain 2 is not available), blowerBay4(6) (if Power Domain 2 is not available), managementModuleBay1(7), managementModuleBay2(8), switchModuleBay1(9), switchModuleBay2(10), switchModuleBay3(11), switchModuleBay4(12), serverBladeBay1(13), serverBladeBay2(14), serverBladeBay3(15), serverBladeBay4(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter HT: notApplicable(1), mediatrayBay1(2), mediatrayBay2(3), fanPackBay1(4), fanPackBay2(5), fanPackBay3(6), fanPackBay4(7), blowerBay1(8), blowerBay2(9), blowerBay3(10), blowerBay4(11), networkclockBay1(12), networkclockBay2(13), midplaneelectroBay1(14), midplaneelectroBay2(15), notApplicable(16), managementModuleBay1(17), managementModuleBay2(18), ioModuleBay1(19), ioModuleBay2(20), ioModuleBay3(21), ioModuleBay4(22), serverBladeBay1(23), serverBladeBay2(24), serverBladeBay3(25), serverBladeBay4(26), serverBladeBay5(27), serverBladeBay6(28), notApplicable(29) The following Bay Number IDs are used in the BladeCenter S: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), blowerBay1(7), blowerBay2(8), blowerBay3(9), blowerBay4(10), storageModuleBay1(11), storageModuleBay2(12), managementModuleBay(13), ioModuleBay1(14), ioModuleBay2(15), ioModuleBay3(16), ioModuleBay4(17), serverBladeBay1(18), serverBladeBay2(19), serverBladeBay3(20), serverBladeBay4(21), serverBladeBay5(22), serverBladeBay6(23), notApplicable(24)
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- powerDomain1Entry
- Table
- powerDomain1Table
- Siblings
- 12
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pd1Index mandatory Power Domain 1 Table Index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1 |
| pd1ModuleCPUDutyCycles mandatory Power Domain 1 Table Module CPUs Duty Cycles applies to blade
servers only. It displays the duty cycle for each CPU on the blade
as a percentage. Note that some blades do not re… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10 |
| pd1ModuleThrottle mandatory Power Domain 1 Table Module Throttle indicates whether the
server blade may be allowed to throttle or not.
When a 1200W or 1400W power module is installed in the domain
the power … | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11 |
| pd1ModulePowerCapabilities mandatory Power Domain 1 Table Module Power Capabilities.
staticPowerManagement: the module with the static worst
case power values.
fixedPowermanagement: the module with… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12 |
| pd1ModuleMeasuredOrStatic mandatory Power Domain 1 Table Module Measured Or Static. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13 |
| pd1BladePrimarySlot mandatory Power Domain 1 Table Blade Primary Slot can be useful
when a server blade spans multiple slots (e.g. double wide or
triple wide). For example if the blade is double wide and
is i… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3 |
| pd1ModuleStatus mandatory Power Domain 1 Table Module Throttle Status. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4 |
| pd1ModuleName mandatory Power Domain 1 Table Module Name. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5 |
| pd1ModuleState mandatory Power Domain 1 Table Module State. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6 |
| pd1ModuleAllocatedPowerCurrent mandatory Power Domain 1 Table Allocated Power Current indicates the current power
allocation for the module in Watts. When a 1200W or 1400W power module is
installed in the domain the powe… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7 |
| pd1ModuleAllocatedPowerMax mandatory Power Domain 1 Table Allocated Power Max indicates the maximum power
allocation for the module in Watts. It is indicative of the maximum
amount of power the module will consume i… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8 |
| pd1ModuleAllocatedPowerMin mandatory Power Domain 1 Table Allocated Power Min indicates the minumum power
allocation for the module in Watts. It is indicative of the minumum
power consumption of the component in the… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9 |