pd1ModuleAllocatedPowerMax
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8
Object
column
mandatory
OctetString
Power Domain 1 Table Allocated Power Max indicates the maximum power
allocation for the module in Watts. It is indicative of the maximum
amount of power the module will consume in the domain when it is
fully populated with memory chips, expansion cards, etc.
When a 1200W or 1400W power module is installed in the domain
the power management policy will not be applicable.
In addition the power consumption in this domain will not be monitored.
NOTE: When a server blade spans multiple slots (e.g. double wide or
triple wide), the maximum power allocation for the module is equally
divided among the slots.
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- powerDomain1Entry
- Table
- powerDomain1Table
- Siblings
- 12
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pd1Index mandatory Power Domain 1 Table Index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1 |
| pd1ModuleCPUDutyCycles mandatory Power Domain 1 Table Module CPUs Duty Cycles applies to blade
servers only. It displays the duty cycle for each CPU on the blade
as a percentage. Note that some blades do not re… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10 |
| pd1ModuleThrottle mandatory Power Domain 1 Table Module Throttle indicates whether the
server blade may be allowed to throttle or not.
When a 1200W or 1400W power module is installed in the domain
the power … | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11 |
| pd1ModulePowerCapabilities mandatory Power Domain 1 Table Module Power Capabilities.
staticPowerManagement: the module with the static worst
case power values.
fixedPowermanagement: the module with… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12 |
| pd1ModuleMeasuredOrStatic mandatory Power Domain 1 Table Module Measured Or Static. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13 |
| pd1BayNumber mandatory Power Domain 1 Table Bay Number.
The following Bay Number IDs are used in the BladeCenter:
notApplicable(1),
notApplicable(2),
blowerBay1(3),
blowerBay2(4),
managementModuleB… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2 |
| pd1BladePrimarySlot mandatory Power Domain 1 Table Blade Primary Slot can be useful
when a server blade spans multiple slots (e.g. double wide or
triple wide). For example if the blade is double wide and
is i… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3 |
| pd1ModuleStatus mandatory Power Domain 1 Table Module Throttle Status. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4 |
| pd1ModuleName mandatory Power Domain 1 Table Module Name. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5 |
| pd1ModuleState mandatory Power Domain 1 Table Module State. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6 |
| pd1ModuleAllocatedPowerCurrent mandatory Power Domain 1 Table Allocated Power Current indicates the current power
allocation for the module in Watts. When a 1200W or 1400W power module is
installed in the domain the powe… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7 |
| pd1ModuleAllocatedPowerMin mandatory Power Domain 1 Table Allocated Power Min indicates the minumum power
allocation for the module in Watts. It is indicative of the minumum
power consumption of the component in the… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9 |