WebGraph-Thermometer-NTC-US-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
9
Rows
9
Columns
59
.1.3.6.1.4.1.5040.1.2.38.1.2 · 1 row entry · 1 columns
List of sensors.
wtWebioAn1GraphNtcSensorEntry entry .1.3.6.1.4.1.5040.1.2.38.1.2.1
Temperature sensor numbers.
Indexes
wtWebioAn1GraphNtcSensorNo
Column Syntax OID
wtWebioAn1GraphNtcSensorNo mandatory
Temperature sensor number.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.38.1.2.1.1
.1.3.6.1.4.1.5040.1.2.38.1.3 · 1 row entry · 1 columns
List of temperature values corresponding to the channel numbers.
wtWebioAn1GraphNtcTempValueEntry entry .1.3.6.1.4.1.5040.1.2.38.1.3.1
Temperatures of the sensors.
Indexes
wtWebioAn1GraphNtcSensorNo
Column Syntax OID
wtWebioAn1GraphNtcTempValue mandatory
Temperature value of the sensor, ASCII, 5 characters in length.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.38.1.3.1.1
.1.3.6.1.4.1.5040.1.2.38.1.4 · 1 row entry · 1 columns
List of binary temperature values corresponding to the channel numbers.
wtWebioAn1GraphNtcBinaryTempValueEntry entry .1.3.6.1.4.1.5040.1.2.38.1.4.1
Binary temperature values of the sensors.
Indexes
wtWebioAn1GraphNtcSensorNo
Column Syntax OID
wtWebioAn1GraphNtcBinaryTempValue mandatory
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.38.1.4.1.1
.1.3.6.1.4.1.5040.1.2.38.1.8 · 1 row entry · 1 columns
List of temperature values corresponding to the channel numbers.
wtWebioAn1GraphNtcTempValuePktEntry entry .1.3.6.1.4.1.5040.1.2.38.1.8.1
Temperatures of the sensors.
Indexes
wtWebioAn1GraphNtcSensorNo
Column Syntax OID
wtWebioAn1GraphNtcTempValuePkt mandatory
Temperature value of the sensor, ASCII, 5 characters in length, decimal point.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.38.1.8.1.1
.1.3.6.1.4.1.5040.1.2.38.3.1.4.4 · 1 row entry · 1 columns
List of sensor colors for the praphical presentation.
wtWebioAn1GraphNtcSensorColorEntry entry .1.3.6.1.4.1.5040.1.2.38.3.1.4.4.1
Index numbers of the sensors.
Indexes
wtWebioAn1GraphNtcSensorNo
Column Syntax OID
wtWebioAn1GraphNtcSensorColor mandatory
Color of the sensors at the praphical presention.
OctetStringr/w
Constraints:
range: 3-3
.1.3.6.1.4.1.5040.1.2.38.3.1.4.4.1.1
.1.3.6.1.4.1.5040.1.2.38.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioAn1GraphNtcAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.38.3.1.5.2.1
Numbers of the alarms.
Indexes
wtWebioAn1GraphNtcAlarmNo
Column Syntax OID
wtWebioAn1GraphNtcAlarmNo mandatory
Alarm number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.38.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3 · 1 row entry · 44 columns
List of settings depending on the alarm number.
wtWebioAn1GraphNtcAlarmEntry entry .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
wtWebioAn1GraphNtcAlarmNo
Column Syntax OID
wtWebioAn1GraphNtcAlarmTrigger mandatory
Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart

Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
B…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.1
wtWebioAn1GraphNtcAlarmMin mandatory
Minimum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.2
wtWebioAn1GraphNtcAlarmMax mandatory
Maximum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.3
wtWebioAn1GraphNtcAlarmHysteresis mandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.4
wtWebioAn1GraphNtcAlarmDelay mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes).
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.5
wtWebioAn1GraphNtcAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.6
wtWebioAn1GraphNtcAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.7
wtWebioAn1GraphNtcAlarmEMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.8
wtWebioAn1GraphNtcAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.9
wtWebioAn1GraphNtcAlarmMailText mandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.10
wtWebioAn1GraphNtcAlarmManagerIP mandatory
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.11
wtWebioAn1GraphNtcAlarmTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.12
wtWebioAn1GraphNtcAlarmMailOptions mandatory
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.13
wtWebioAn1GraphNtcAlarmTcpIpAddr mandatory
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.14
wtWebioAn1GraphNtcAlarmTcpPort mandatory
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.15
wtWebioAn1GraphNtcAlarmTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.16
wtWebioAn1GraphNtcAlarmClearMailSubject mandatory
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.17
wtWebioAn1GraphNtcAlarmClearMailText mandatory
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.18
wtWebioAn1GraphNtcAlarmClearTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.19
wtWebioAn1GraphNtcAlarmClearTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.20
wtWebioAn1GraphNtcAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.21
wtWebioAn1GraphNtcAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.22
wtWebioAn1GraphNtcAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.23
wtWebioAn1GraphNtcAlarmSyslogClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.24
wtWebioAn1GraphNtcAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.25
wtWebioAn1GraphNtcAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.26
wtWebioAn1GraphNtcAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.27
wtWebioAn1GraphNtcAlarmFtpClearText mandatory
Alarm clear message to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.28
wtWebioAn1GraphNtcAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.29
wtWebioAn1GraphNtcAlarmTimerCron mandatory
This entry contains 5 text fields space or tab seperated for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separately.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.30
wtWebioAn1GraphNtcAlarmDeltaTemp mandatory
Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.31
wtWebioAn1GraphNtcAlarmName mandatory
Alert name
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.39
wtWebioAn1GraphNtcAlarmActive mandatory
Alert active
1 = ON
0 = OFF
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.40
wtWebioAn1GraphNtcAlarmHttpReqAuthEnable mandatory
Binary coded options, select only one option at the same time:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.61
wtWebioAn1GraphNtcAlarmHttpReqAuthUser mandatory
HTTP Request: User
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.62
wtWebioAn1GraphNtcAlarmHttpReqAuthPassword mandatory
HTTP Request: Password
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.63
wtWebioAn1GraphNtcAlarmHttpReqSetUrl mandatory
HTTP Request: Set URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.64
wtWebioAn1GraphNtcAlarmHttpReqClearUrl mandatory
HTTP Request: Clear URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.65
wtWebioAn1GraphNtcAlarmHttpReqServerPort mandatory
HTTP Request: Server Port
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.66
wtWebioAn1GraphNtcAlarmMqttTopicPath mandatory
MQTT Publish: Topic path
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.67
wtWebioAn1GraphNtcAlarmMqttTopicSetTopic mandatory
MQTT Publish: Topic SET message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.68
wtWebioAn1GraphNtcAlarmMqttTopicClear mandatory
MQTT Publish: Topic CLEAR message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.69
wtWebioAn1GraphNtcAlarmSensorLostSelection mandatory
Binary coded options:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Sensor 0
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.70
wtWebioAn1GraphNtcAlarmLimitWindow mandatory
If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE
the alarm is generated when the measured value is lower than the mini…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.71
.1.3.6.1.4.1.5040.1.2.38.3.1.6.2.3 · 1 row entry · 2 columns
List of sensor colors for the praphical presentation.
wtWebioAn1GraphNtc2SensorColorEntry entry .1.3.6.1.4.1.5040.1.2.38.3.1.6.2.3.1
Numbers of the sensors.
Indexes
wtWebioAn1GraphNtcSensorNo
Column Syntax OID
wtWebioAn1GraphNtcGraphicsSensorColor mandatory
Color of the sensors at the praphical presention.
OctetStringr/w
Constraints:
range: 3-3
.1.3.6.1.4.1.5040.1.2.38.3.1.6.2.3.1.1
wtWebioAn1GraphNtcGraphicsSelectScale mandatory
Assignes one of 4 scales to a sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Use Scale 1
Bit 1-7: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.1.6.2.3.1.2
.1.3.6.1.4.1.5040.1.2.38.3.2.1 · 1 row entry · 7 columns
List of settings depending on the sensor number.
wtWebioAn1GraphNtcPortEntry entry .1.3.6.1.4.1.5040.1.2.38.3.2.1.1
Sensor parameters for the individual sensors.
Indexes
wtWebioAn1GraphNtcSensorNo
Column Syntax OID
wtWebioAn1GraphNtcPortName mandatory
Name of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.2.1.1.1
wtWebioAn1GraphNtcPortText mandatory
Description of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.2.1.1.2
wtWebioAn1GraphNtcPortOffset1 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.2.1.1.3
wtWebioAn1GraphNtcPortTemperature1 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.2.1.1.4
wtWebioAn1GraphNtcPortOffset2 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.2.1.1.5
wtWebioAn1GraphNtcPortTemperature2 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.2.1.1.6
wtWebioAn1GraphNtcPortComment mandatory
Offset calibration: informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.38.3.2.1.1.7