wtWebioAn1GraphNtcAlarmDeltaTemp
WebGraph-Thermometer-NTC-US-MIB ·
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.31
Object
column
mandatory
r/w
OctetString
Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes.
Context
- MIB
- WebGraph-Thermometer-NTC-US-MIB
- OID
.1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.31- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioAn1GraphNtcAlarmEntry
- Table
- wtWebioAn1GraphNtcAlarmTable
- Siblings
- 43
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioAn1GraphNtcAlarmTrigger mandatory Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart
Octet 4:
Bit 0: Sensor 1
Bit 1: Senso… | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.1 |
| wtWebioAn1GraphNtcAlarmMailText mandatory Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.10 |
| wtWebioAn1GraphNtcAlarmManagerIP mandatory Name or IP address of the SNMP Manager which accepts the trap. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.11 |
| wtWebioAn1GraphNtcAlarmTrapText mandatory This text is sent in the trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.12 |
| wtWebioAn1GraphNtcAlarmMailOptions mandatory Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.13 |
| wtWebioAn1GraphNtcAlarmTcpIpAddr mandatory Name or IP address of the TCP server which accepts the trap. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.14 |
| wtWebioAn1GraphNtcAlarmTcpPort mandatory Port number of the TCP server which accepts the trap. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.15 |
| wtWebioAn1GraphNtcAlarmTcpText mandatory This text is sent in the TCP trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.16 |
| wtWebioAn1GraphNtcAlarmClearMailSubject mandatory Subject line for alarm clear mail. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.17 |
| wtWebioAn1GraphNtcAlarmClearMailText mandatory Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.18 |
| wtWebioAn1GraphNtcAlarmClearTrapText mandatory This text is sent in the trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.19 |
| wtWebioAn1GraphNtcAlarmMin mandatory Minimum temperature in degrees with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.2 |
| wtWebioAn1GraphNtcAlarmClearTcpText mandatory This text is sent in the TCP trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.20 |
| wtWebioAn1GraphNtcAlarmSyslogIpAddr mandatory IP address of the syslog server to which the Webio device should send syslog messages. | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.21 |
| wtWebioAn1GraphNtcAlarmSyslogPort mandatory Port number of the syslog server to which the Webio device should send syslog messages. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.22 |
| wtWebioAn1GraphNtcAlarmSyslogText mandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.23 |
| wtWebioAn1GraphNtcAlarmSyslogClearText mandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.24 |
| wtWebioAn1GraphNtcAlarmFtpDataPort mandatory Local data port: 1..65535 or AUTO: the next free port will be assigned. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.25 |
| wtWebioAn1GraphNtcAlarmFtpFileName mandatory Name of the file including path informations. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.26 |
| wtWebioAn1GraphNtcAlarmFtpText mandatory Message text to store on the FTP server. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.27 |
| wtWebioAn1GraphNtcAlarmFtpClearText mandatory Alarm clear message to store on the FTP server. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.28 |
| wtWebioAn1GraphNtcAlarmFtpOption mandatory Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.29 |
| wtWebioAn1GraphNtcAlarmMax mandatory Maximum temperature in degrees with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.3 |
| wtWebioAn1GraphNtcAlarmTimerCron mandatory This entry contains 5 text fields space or tab seperated for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are… | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.30 |
| wtWebioAn1GraphNtcAlarmName mandatory Alert name | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.39 |
| wtWebioAn1GraphNtcAlarmHysteresis mandatory Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.4 |
| wtWebioAn1GraphNtcAlarmActive mandatory Alert active
1 = ON
0 = OFF | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.40 |
| wtWebioAn1GraphNtcAlarmDelay mandatory Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.5 |
| wtWebioAn1GraphNtcAlarmInterval mandatory Send interval for alarm messages. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.6 |
| wtWebioAn1GraphNtcAlarmHttpReqAuthEnable mandatory Binary coded options, select only one option at the same time:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.61 |
| wtWebioAn1GraphNtcAlarmHttpReqAuthUser mandatory HTTP Request: User | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.62 |
| wtWebioAn1GraphNtcAlarmHttpReqAuthPassword mandatory HTTP Request: Password | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.63 |
| wtWebioAn1GraphNtcAlarmHttpReqSetUrl mandatory HTTP Request: Set URL | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.64 |
| wtWebioAn1GraphNtcAlarmHttpReqClearUrl mandatory HTTP Request: Clear URL | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.65 |
| wtWebioAn1GraphNtcAlarmHttpReqServerPort mandatory HTTP Request: Server Port | column | Integer32 | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.66 |
| wtWebioAn1GraphNtcAlarmMqttTopicPath mandatory MQTT Publish: Topic path | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.67 |
| wtWebioAn1GraphNtcAlarmMqttTopicSetTopic mandatory MQTT Publish: Topic SET message | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.68 |
| wtWebioAn1GraphNtcAlarmMqttTopicClear mandatory MQTT Publish: Topic CLEAR message | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.69 |
| wtWebioAn1GraphNtcAlarmEnable mandatory Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.7 |
| wtWebioAn1GraphNtcAlarmSensorLostSelection mandatory Binary coded options:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Sensor 0 | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.70 |
| wtWebioAn1GraphNtcAlarmLimitWindow mandatory If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE
the alarm is generated when t… | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.71 |
| wtWebioAn1GraphNtcAlarmEMailAddr mandatory E-Mail address for sending the alarm mail to. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.8 |
| wtWebioAn1GraphNtcAlarmMailSubject mandatory Subject line for alarm mail. | column | OctetString | .1.3.6.1.4.1.5040.1.2.38.3.1.5.3.1.9 |