WebGraph-OLD-Thermometer-PT-US-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
23
Rows
23
Columns
132
.1.3.6.1.4.1.5040.1.2.17.1.2 · 1 row entry · 1 columns
List of sensors.
wtWebioAn1GraphPtSensorEntry entry .1.3.6.1.4.1.5040.1.2.17.1.2.1
Temperature sensor numbers.
Indexes
wtWebioAn1GraphPtSensorNo
Column Syntax OID
wtWebioAn1GraphPtSensorNo mandatory
Temperature sensor number.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.17.1.2.1.1
.1.3.6.1.4.1.5040.1.2.17.1.3 · 1 row entry · 1 columns
List of temperature values corresponding to the channel numbers.
wtWebioAn1GraphPtTempValueEntry entry .1.3.6.1.4.1.5040.1.2.17.1.3.1
Temperatures of the sensors.
Indexes
wtWebioAn1GraphPtSensorNo
Column Syntax OID
wtWebioAn1GraphPtTempValue mandatory
Temperature value of the sensor, ASCII, 5 characters in length.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.17.1.3.1.1
.1.3.6.1.4.1.5040.1.2.17.1.4 · 1 row entry · 1 columns
List of binary temperature values corresponding to the channel numbers.
wtWebioAn1GraphPtBinaryTempValueEntry entry .1.3.6.1.4.1.5040.1.2.17.1.4.1
Binary temperature values of the sensors.
Indexes
wtWebioAn1GraphPtSensorNo
Column Syntax OID
wtWebioAn1GraphPtBinaryTempValue mandatory
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.17.1.4.1.1
.1.3.6.1.4.1.5040.1.2.17.1.8 · 1 row entry · 1 columns
List of temperature values corresponding to the channel numbers.
wtWebioAn1GraphPtTempValuePktEntry entry .1.3.6.1.4.1.5040.1.2.17.1.8.1
Temperatures of the sensors.
Indexes
wtWebioAn1GraphPtSensorNo
Column Syntax OID
wtWebioAn1GraphPtTempValuePkt mandatory
Temperature value of the sensor, ASCII, 5 characters in length, decimal point.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.17.1.8.1.1
.1.3.6.1.4.1.5040.1.2.17.3.1.4.4 · 1 row entry · 1 columns
List of sensor colors for the praphical presentation.
wtWebioAn1GraphPtSensorColorEntry entry .1.3.6.1.4.1.5040.1.2.17.3.1.4.4.1
Index numbers of the sensors.
Indexes
wtWebioAn1GraphPtSensorNo
Column Syntax OID
wtWebioAn1GraphPtSensorColor mandatory
Color of the sensors at the praphical presention.
OctetStringr/w
Constraints:
range: 3-3
.1.3.6.1.4.1.5040.1.2.17.3.1.4.4.1.1
.1.3.6.1.4.1.5040.1.2.17.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioAn1GraphPtAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.17.3.1.5.2.1
Numbers of the alarms.
Indexes
wtWebioAn1GraphPtAlarmNo
Column Syntax OID
wtWebioAn1GraphPtAlarmNo mandatory
Alarm number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.17.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.17.3.1.5.3 · 1 row entry · 33 columns
List of settings depending on the alarm number.
wtWebioAn1GraphPtAlarmEntry entry .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
wtWebioAn1GraphPtAlarmNo
Column Syntax OID
wtWebioAn1GraphPtAlarmTrigger mandatory
Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0 : Timer
Bit 1 : ColdStart
Bit 2 : WarmStart
Bit 3 : Sensor lost
Bit 4-7: unused

Octet 4:
Bit 0 : Sensor 1
Bit 1…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.1
wtWebioAn1GraphPtAlarmMin mandatory
Minimum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.2
wtWebioAn1GraphPtAlarmMax mandatory
Maximum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.3
wtWebioAn1GraphPtAlarmHysteresis mandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.4
wtWebioAn1GraphPtAlarmDelay mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes).
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.5
wtWebioAn1GraphPtAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.6
wtWebioAn1GraphPtAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Mail Enable
Bit 1 : SNMP Trap enable
Bit 2 : TCP Client enable
Bit 3 : Syslog Messages enable
Bit 4 : FTP enable
Bi…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.7
wtWebioAn1GraphPtAlarmEMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.8
wtWebioAn1GraphPtAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.9
wtWebioAn1GraphPtAlarmMailText mandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.10
wtWebioAn1GraphPtAlarmManagerIP mandatory
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.11
wtWebioAn1GraphPtAlarmTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.12
wtWebioAn1GraphPtAlarmMailOptions mandatory
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.13
wtWebioAn1GraphPtAlarmTcpIpAddr mandatory
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.14
wtWebioAn1GraphPtAlarmTcpPort mandatory
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.15
wtWebioAn1GraphPtAlarmTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.16
wtWebioAn1GraphPtAlarmClearMailSubject mandatory
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.17
wtWebioAn1GraphPtAlarmClearMailText mandatory
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.18
wtWebioAn1GraphPtAlarmClearTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.19
wtWebioAn1GraphPtAlarmClearTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.20
wtWebioAn1GraphPtAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.21
wtWebioAn1GraphPtAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.22
wtWebioAn1GraphPtAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.23
wtWebioAn1GraphPtAlarmSyslogClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.24
wtWebioAn1GraphPtAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.25
wtWebioAn1GraphPtAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.26
wtWebioAn1GraphPtAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.27
wtWebioAn1GraphPtAlarmFtpClearText mandatory
Alarm clear message to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.28
wtWebioAn1GraphPtAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.29
wtWebioAn1GraphPtAlarmTimerCron mandatory
This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab.
The activation time of the report is defined by a…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.30
wtWebioAn1GraphPtAlarmDeltaTemp mandatory
Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.31
wtWebioAn1GraphPtAlarmName mandatory
Alert name
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.39
wtWebioAn1GraphPtAlarmActive mandatory
Alert active
1 = ON
0 = OFF
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.40
.1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3 · 1 row entry · 2 columns
List of sensor colors for the praphical presentation.
wtWebioAn1GraphPt2SensorColorEntry entry .1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1
Numbers of the sensors.
Indexes
wtWebioAn1GraphPtSensorNo
Column Syntax OID
wtWebioAn1GraphPt2GraphicsSensorColor mandatory
Color of the sensors at the praphical presention.
OctetStringr/w
Constraints:
range: 3-3
.1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1.1
wtWebioAn1GraphPt2GraphicsSelectScale mandatory
Assignes one of 4 scales to a sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Use Scale 1
Bit 1-7: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1.2
.1.3.6.1.4.1.5040.1.2.17.3.2.1 · 1 row entry · 8 columns
List of settings depending on the sensor number.
wtWebioAn1GraphPtPortEntry entry .1.3.6.1.4.1.5040.1.2.17.3.2.1.1
Sensor parameters for the individual sensors.
Indexes
wtWebioAn1GraphPtSensorNo
Column Syntax OID
wtWebioAn1GraphPtPortName mandatory
Name of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.1
wtWebioAn1GraphPtPortText mandatory
Description of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.2
wtWebioAn1GraphPtPortOffset1 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.3
wtWebioAn1GraphPtPortTemperature1 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.4
wtWebioAn1GraphPtPortOffset2 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.5
wtWebioAn1GraphPtPortTemperature2 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.6
wtWebioAn1GraphPtPortComment mandatory
Offset calibration: informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.7
wtWebioAn1GraphPtPortSensorSelect mandatory
Binary coded options of the sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : PT100 (default)
Bit 1 : PT1000
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.17.3.2.1.1.8
.1.3.6.1.4.1.5040.1.2.23.1.2 · 1 row entry · 1 columns
List of sensors.
wtWebioAn1GraphPtSwSensorEntry entry .1.3.6.1.4.1.5040.1.2.23.1.2.1
Temperature sensor numbers.
Indexes
wtWebioAn1GraphPtSwSensorNo
Column Syntax OID
wtWebioAn1GraphPtSwSensorNo mandatory
Temperature sensor number.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.23.1.2.1.1
.1.3.6.1.4.1.5040.1.2.23.1.3 · 1 row entry · 1 columns
List of temperature values corresponding to the channel numbers.
wtWebioAn1GraphPtSwTempValueEntry entry .1.3.6.1.4.1.5040.1.2.23.1.3.1
Temperatures of the sensors.
Indexes
wtWebioAn1GraphPtSwSensorNo
Column Syntax OID
wtWebioAn1GraphPtSwTempValue mandatory
Temperature value of the sensor, ASCII, 5 characters in length.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.23.1.3.1.1
.1.3.6.1.4.1.5040.1.2.23.1.4 · 1 row entry · 1 columns
List of binary temperature values corresponding to the channel numbers.
wtWebioAn1GraphPtSwBinaryTempValueEntry entry .1.3.6.1.4.1.5040.1.2.23.1.4.1
Binary temperature values of the sensors.
Indexes
wtWebioAn1GraphPtSwSensorNo
Column Syntax OID
wtWebioAn1GraphPtSwBinaryTempValue mandatory
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.23.1.4.1.1
.1.3.6.1.4.1.5040.1.2.23.1.6 · 1 row entry · 1 columns
List of outputs.
wtWebioAn1GraphPtSwOutputEntry entry .1.3.6.1.4.1.5040.1.2.23.1.6.1
Output numbers.
Indexes
wtWebioAn1GraphPtSwOutputNo
Column Syntax OID
wtWebioAn1GraphPtSwOutputNo mandatory
Output number.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.23.1.6.1.1
.1.3.6.1.4.1.5040.1.2.23.1.7 · 1 row entry · 1 columns
List of binary ouput values corresponding to the channel numbers.
wtWebioAn1GraphPtSwBinaryOutputValueEntry entry .1.3.6.1.4.1.5040.1.2.23.1.7.1
Binary states of the outputs.
Indexes
wtWebioAn1GraphPtSwOutputNo
Column Syntax OID
wtWebioAn1GraphPtSwBinaryOutputValue mandatory
Binary state of the output.
Enumeration
Enumerated Values:
0wtWebioAn1GraphPtSwBinaryOutput-OFF
1wtWebioAn1GraphPtSwBinaryOutput-ON
.1.3.6.1.4.1.5040.1.2.23.1.7.1.1
.1.3.6.1.4.1.5040.1.2.23.1.8 · 1 row entry · 1 columns
List of temperature values corresponding to the channel numbers.
wtWebioAn1GraphPtSwTempValuePktEntry entry .1.3.6.1.4.1.5040.1.2.23.1.8.1
Temperatures of the sensors.
Indexes
wtWebioAn1GraphPtSwSensorNo
Column Syntax OID
wtWebioAn1GraphPtSwTempValuePkt mandatory
Temperature value of the sensor, ASCII, 5 characters in length, decimal point.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.23.1.8.1.1
.1.3.6.1.4.1.5040.1.2.23.3.1.4.4 · 1 row entry · 1 columns
List of sensor colors for the praphical presentation.
wtWebioAn1GraphPtSwSensorColorEntry entry .1.3.6.1.4.1.5040.1.2.23.3.1.4.4.1
Index numbers of the sensors.
Indexes
wtWebioAn1GraphPtSwSensorNo
Column Syntax OID
wtWebioAn1GraphPtSwSensorColor mandatory
Color of the sensors at the praphical presention.
OctetStringr/w
Constraints:
range: 3-3
.1.3.6.1.4.1.5040.1.2.23.3.1.4.4.1.1
.1.3.6.1.4.1.5040.1.2.23.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioAn1GraphPtSwAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.23.3.1.5.2.1
Numbers of the alarms.
Indexes
wtWebioAn1GraphPtSwAlarmNo
Column Syntax OID
wtWebioAn1GraphPtSwAlarmNo mandatory
Alarm number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.23.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.23.3.1.5.3 · 1 row entry · 33 columns
List of settings depending on the alarm number.
wtWebioAn1GraphPtSwAlarmEntry entry .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
wtWebioAn1GraphPtSwAlarmNo
Column Syntax OID
wtWebioAn1GraphPtSwAlarmTrigger mandatory
Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0 : Timer
Bit 1 : ColdStart
Bit 2 : WarmStart
Bit 3 : Sensor lost
Bit 4-7: unused
Octet 4:
Bit 0 : Sensor 1
Bit 1-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.1
wtWebioAn1GraphPtSwAlarmMin mandatory
Minimum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.2
wtWebioAn1GraphPtSwAlarmMax mandatory
Maximum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.3
wtWebioAn1GraphPtSwAlarmHysteresis mandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.4
wtWebioAn1GraphPtSwAlarmDelay mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes).
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.5
wtWebioAn1GraphPtSwAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.6
wtWebioAn1GraphPtSwAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Output switch enable
Bit 1 : Mail Enable
Bit 2 : SNMP Trap enable
Bit 3 : TCP Client enable
Bit 4 : Syslog Messages …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.7
wtWebioAn1GraphPtSwAlarmEMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.8
wtWebioAn1GraphPtSwAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.9
wtWebioAn1GraphPtSwAlarmMailText mandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.10
wtWebioAn1GraphPtSwAlarmManagerIP mandatory
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.11
wtWebioAn1GraphPtSwAlarmTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.12
wtWebioAn1GraphPtSwAlarmMailOptions mandatory
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.13
wtWebioAn1GraphPtSwAlarmTcpIpAddr mandatory
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.14
wtWebioAn1GraphPtSwAlarmTcpPort mandatory
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.15
wtWebioAn1GraphPtSwAlarmTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.16
wtWebioAn1GraphPtSwAlarmClearMailSubject mandatory
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.17
wtWebioAn1GraphPtSwAlarmClearMailText mandatory
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.18
wtWebioAn1GraphPtSwAlarmClearTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.19
wtWebioAn1GraphPtSwAlarmClearTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.20
wtWebioAn1GraphPtSwAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.21
wtWebioAn1GraphPtSwAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.22
wtWebioAn1GraphPtSwAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.23
wtWebioAn1GraphPtSwAlarmSyslogClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.24
wtWebioAn1GraphPtSwAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.25
wtWebioAn1GraphPtSwAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.26
wtWebioAn1GraphPtSwAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.27
wtWebioAn1GraphPtSwAlarmFtpClearText mandatory
Alarm clear message to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.28
wtWebioAn1GraphPtSwAlarmFtpOptions mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.29
wtWebioAn1GraphPtSwAlarmTimerCron mandatory
This entry contains 5 text fields space or tab seperated for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separately.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.30
wtWebioAn1GraphPtSwAlarmDeltaTemp mandatory
Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.31
wtWebioAn1GraphPtSwAlarmName mandatory
Alert name
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.39
wtWebioAn1GraphPtSwAlarmActive mandatory
Alert active
1 = ON
0 = OFF
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.40
.1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3 · 1 row entry · 2 columns
List of sensor colors for the praphical presentation.
wtWebioAn1GraphPtSw2SensorColorEntry entry .1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1
Numbers of the sensors.
Indexes
wtWebioAn1GraphPtSwSensorNo
Column Syntax OID
wtWebioAn1GraphPtSw2GraphicsSensorColor mandatory
Color of the sensors at the praphical presention.
OctetStringr/w
Constraints:
range: 3-3
.1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1.1
wtWebioAn1GraphPtSw2GraphicsSelectScale mandatory
Assignes one of 4 scales to a sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Use Scale 1
Bit 1-7: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1.2
.1.3.6.1.4.1.5040.1.2.23.3.1.7.2 · 1 row entry · 1 columns
List of Report indices.
wtWebioAn1GraphPtSwReportIfEntry entry .1.3.6.1.4.1.5040.1.2.23.3.1.7.2.1
Numbers of the Reports.
Indexes
wtWebioAn1GraphPtSwReportNo
Column Syntax OID
wtWebioAn1GraphPtSwReportNo mandatory
Report number.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.23.3.1.7.2.1.1
.1.3.6.1.4.1.5040.1.2.23.3.1.7.3 · 1 row entry · 25 columns
List of settings depending on the Report number.
wtWebioAn1GraphPtSwReportEntry entry .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1
Report parameters of the individual Reports.
Indexes
wtWebioAn1GraphPtSwReportNo
Column Syntax OID
wtWebioAn1GraphPtSwReportEnable mandatory
Bin?r kodierte Triggerbedingungen:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Report enable
Bit 1-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.1
wtWebioAn1GraphPtSwReportTimerCron mandatory
This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab.
The activation time of the report is defined by a…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.2
wtWebioAn1GraphPtSwReportMethodeEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
Bit 3: Syslog enable
Bit 4: FTP Client enable
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.3
wtWebioAn1GraphPtSwReportEMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.8
wtWebioAn1GraphPtSwReportMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.9
wtWebioAn1GraphPtSwReportMailText mandatory
Report mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.10
wtWebioAn1GraphPtSwReportManagerIP mandatory
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.11
wtWebioAn1GraphPtSwReportTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.12
wtWebioAn1GraphPtSwReportMailOptions mandatory
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Logger.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.13
wtWebioAn1GraphPtSwReportTcpIpAddr mandatory
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.14
wtWebioAn1GraphPtSwReportTcpPort mandatory
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.15
wtWebioAn1GraphPtSwReportTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.16
wtWebioAn1GraphPtSwReportClearMailSubject mandatory
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.17
wtWebioAn1GraphPtSwReportClearMailText mandatory
Report clear mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.18
wtWebioAn1GraphPtSwReportClearTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.19
wtWebioAn1GraphPtSwReportClearTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.20
wtWebioAn1GraphPtSwReportSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.24
wtWebioAn1GraphPtSwReportSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.25
wtWebioAn1GraphPtSwReportSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.26
wtWebioAn1GraphPtSwReportSyslogClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.27
wtWebioAn1GraphPtSwReportFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.28
wtWebioAn1GraphPtSwReportFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.29
wtWebioAn1GraphPtSwReportFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.30
wtWebioAn1GraphPtSwReportFtpClearText mandatory
Report clear message to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.31
wtWebioAn1GraphPtSwReportFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.32
.1.3.6.1.4.1.5040.1.2.23.3.2.1 · 1 row entry · 9 columns
List of settings depending on the sensor number.
wtWebioAn1GraphPtSwPortEntry entry .1.3.6.1.4.1.5040.1.2.23.3.2.1.1
Sensor parameters for the individual sensors.
Indexes
wtWebioAn1GraphPtSwSensorNo
Column Syntax OID
wtWebioAn1GraphPtSwPortName mandatory
Name of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.1
wtWebioAn1GraphPtSwPortText mandatory
Description of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.2
wtWebioAn1GraphPtSwPortOffset1 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.3
wtWebioAn1GraphPtSwPortTemperature1 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.4
wtWebioAn1GraphPtSwPortOffset2 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.5
wtWebioAn1GraphPtSwPortTemperature2 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.6
wtWebioAn1GraphPtSwPortComment mandatory
Offset calibration: informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.7
wtWebioAn1GraphPtSwPortSensorSelect mandatory
Binary coded options of the sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : PT100 (default)
Bit 1 : PT1000
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.2.1.1.8
wtWebioAn1GraphPtSwPortSensorUnit mandatory
Binary coded options of the sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Celsius (default)
Bit 1 : Fahrenheit
Bit 2 : Kelvin
Bit 3-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.2.1.1.9
.1.3.6.1.4.1.5040.1.2.23.3.2.3 · 1 row entry · 5 columns
List of settings depending on the sensor number.
wtWebioAn1GraphPtSwPortOutputEntry entry .1.3.6.1.4.1.5040.1.2.23.3.2.3.1
Parameters for the individual outputs.
Indexes
wtWebioAn1GraphPtSwOutputNo
Column Syntax OID
wtWebioAn1GraphPtSwPortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.3.1.1
wtWebioAn1GraphPtSwPortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.3.1.2
wtWebioAn1GraphPtSwPortOutputPolarity mandatory
Binary coded options of the output:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Normally open (default)
Bit 1 : Normally closed
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.2.3.1.3
wtWebioAn1GraphPtSwPortOutputComment mandatory
Additional informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.23.3.2.3.1.4
wtWebioAn1GraphPortOutputResetEnable mandatory
Binary coded options of the output:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Manual Reset enable (default off)
Bit 1-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.23.3.2.3.1.5