WebGraph-Air-Quality-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
8
Rows
8
Columns
65
.1.3.6.1.4.1.5040.1.2.41.1.2
·
1 row entry
·
1 columns
List of sensors.
List of sensor numbers.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualitySensorNo
mandatory
Sensor number.
|
Integer32 | .1.3.6.1.4.1.5040.1.2.41.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.41.1.3
·
1 row entry
·
1 columns
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityTempValue
mandatory
Measurement value of the sensor, ASCII, 5 characters in length.
|
OctetString | .1.3.6.1.4.1.5040.1.2.41.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.41.1.4
·
1 row entry
·
1 columns
List of binary measurement values corresponding to the channel numbers.
Binary measurement values of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityBinaryTempValue
mandatory
Binary measurement value of the sensor in 1/10 degrees Celsius, 1/10 per cent
or 1/10 ppm, signed number, 0x7FFFFFFF indicates an invalid measured value. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.41.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.41.1.8
·
1 row entry
·
1 columns
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityTempValuePkt
mandatory
Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point.
|
OctetString | .1.3.6.1.4.1.5040.1.2.41.1.8.1.1 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.2
·
1 row entry
·
1 columns
List of alarm indices.
Numbers of the alarms.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityAlarmNo
mandatory
Alarm number.
|
Integer32 | .1.3.6.1.4.1.5040.1.2.41.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3
·
1 row entry
·
51 columns
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityAlarmTrigger
mandatory
Binary coded trigger conditions:
Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
OctetStringr/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.1 |
|
wtWebGraphAirQualityAlarmMin
mandatory
Minimum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.2 |
|
wtWebGraphAirQualityAlarmMax
mandatory
Maximum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.3 |
|
wtWebGraphAirQualityAlarmHysteresis
mandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.4 |
|
wtWebGraphAirQualityAlarmDelay
mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.5 |
|
wtWebGraphAirQualityAlarmInterval
mandatory
Send interval for alarm messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.6 |
|
wtWebGraphAirQualityAlarmEnable
mandatory
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.7 |
|
wtWebGraphAirQualityAlarmEMailAddr
mandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.8 |
|
wtWebGraphAirQualityAlarmMailSubject
mandatory
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.9 |
|
wtWebGraphAirQualityAlarmMailText
mandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.10 |
|
wtWebGraphAirQualityAlarmManagerIP
mandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.11 |
|
wtWebGraphAirQualityAlarmTrapText
mandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.12 |
|
wtWebGraphAirQualityAlarmMailOptions
mandatory
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.13 |
|
wtWebGraphAirQualityAlarmTcpIpAddr
mandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.14 |
|
wtWebGraphAirQualityAlarmTcpPort
mandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.15 |
|
wtWebGraphAirQualityAlarmTcpText
mandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.16 |
|
wtWebGraphAirQualityAlarmClearMailSubject
mandatory
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.17 |
|
wtWebGraphAirQualityAlarmClearMailText
mandatory
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.18 |
|
wtWebGraphAirQualityAlarmClearTrapText
mandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.19 |
|
wtWebGraphAirQualityAlarmClearTcpText
mandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.20 |
|
wtWebGraphAirQualityAlarmDeltaTemp
mandatory
Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes. |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.21 |
|
wtWebGraphAirQualityAlarmRHMin
mandatory
Minimum rel. Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.22 |
|
wtWebGraphAirQualityAlarmRHMax
mandatory
Maximum rel.Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.23 |
|
wtWebGraphAirQualityAlarmRHHysteresis
mandatory
Hysteresis of rel. Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.24 |
|
wtWebGraphAirQualityAlarmAHMin
mandatory
Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.25 |
|
wtWebGraphAirQualityAlarmAHMax
mandatory
Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.26 |
|
wtWebGraphAirQualityAlarmSyslogIpAddr
mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.27 |
|
wtWebGraphAirQualityAlarmSyslogPort
mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.28 |
|
wtWebGraphAirQualityAlarmSyslogText
mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.29 |
|
wtWebGraphAirQualityAlarmSyslogClearText
mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.30 |
|
wtWebGraphAirQualityAlarmFtpDataPort
mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.31 |
|
wtWebGraphAirQualityAlarmFtpFileName
mandatory
Name of the file including path informations.
|
OctetStringr/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.32 |
|
wtWebGraphAirQualityAlarmFtpText
mandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.33 |
|
wtWebGraphAirQualityAlarmFtpClearText
mandatory
Alarm clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.34 |
|
wtWebGraphAirQualityAlarmFtpOption
mandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.35 |
|
wtWebGraphAirQualityAlarmTimerCron
mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Rang… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.36 |
|
wtWebGraphAirQualityAlarmVocMax
mandatory
Maximum VOC in ppm with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.37 |
|
wtWebGraphAirQualityAlarmVocHysteresis
mandatory
Hysteresis of VOC in ppm with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.38 |
|
wtWebGraphAirQualityAlarmName
mandatory
Alert name
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.39 |
|
wtWebGraphAirQualityAlarmActive
mandatory
Alert active
1 = ON 0 = OFF |
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.40 |
|
wtWebGraphAirQualityAlarmHttpReqAuthEnable
mandatory
Binary coded options, select only one option at the same time:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.61 |
|
wtWebGraphAirQualityAlarmHttpReqAuthUser
mandatory
HTTP Request: User
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.62 |
|
wtWebGraphAirQualityAlarmHttpReqAuthPassword
mandatory
HTTP Request: Password
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.63 |
|
wtWebGraphAirQualityAlarmHttpReqSetUrl
mandatory
HTTP Request: Set URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.64 |
|
wtWebGraphAirQualityAlarmHttpReqClearUrl
mandatory
HTTP Request: Clear URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.65 |
|
wtWebGraphAirQualityAlarmHttpReqServerPort
mandatory
HTTP Request: Server Port
|
Integer32r/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.66 |
|
wtWebGraphAirQualityAlarmMqttTopicPath
mandatory
MQTT Publish: Topic path
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.67 |
|
wtWebGraphAirQualityAlarmMqttTopicSetTopic
mandatory
MQTT Publish: Topic SET message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.68 |
|
wtWebGraphAirQualityAlarmMqttTopicClear
mandatory
MQTT Publish: Topic CLEAR message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.69 |
|
wtWebGraphAirQualityAlarmSensorLostSelection
mandatory
Binary coded options:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Sensor 2 Bit 1 : Sensor 1 Bit 0 : Sensor 0 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.70 |
|
wtWebGraphAirQualityAlarmLimitWindow
mandatory
If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the mini… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.71 |
.1.3.6.1.4.1.5040.1.2.41.3.1.6.2.3
·
1 row entry
·
2 columns
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityGraphicsSensorColor
mandatory
Color of the sensors at the praphical presention.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.6.2.3.1.1 |
|
wtWebGraphAirQualityGraphicsSelectScale
mandatory
Assignes one of 4 scales to a sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.41.3.2.1
·
1 row entry
·
7 columns
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityPortName
mandatory
Name of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.1 |
|
wtWebGraphAirQualityPortText
mandatory
Description of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.2 |
|
wtWebGraphAirQualityPortOffset1
mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.3 |
|
wtWebGraphAirQualityPortTemperature1
mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.4 |
|
wtWebGraphAirQualityPortOffset2
mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.5 |
|
wtWebGraphAirQualityPortTemperature2
mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.6 |
|
wtWebGraphAirQualityPortComment
mandatory
Offset calibration: informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.7 |