wtWebGraphAirQualityAlarmMin
WebGraph-Air-Quality-US-MIB ·
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.2
Object
column
mandatory
r/w
OctetString
Minimum temperature in degrees with maximum 2 decimal places.
Context
- MIB
- WebGraph-Air-Quality-US-MIB
- OID
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.2- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebGraphAirQualityAlarmEntry
- Table
- wtWebGraphAirQualityAlarmTable
- Siblings
- 50
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebGraphAirQualityAlarmTrigger mandatory Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart
Octet 4:
Bit 0: Sensor 1
Bit 1: Senso… | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.1 |
| wtWebGraphAirQualityAlarmMailText mandatory Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.10 |
| wtWebGraphAirQualityAlarmManagerIP mandatory Name or IP address of the SNMP Manager which accepts the trap. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.11 |
| wtWebGraphAirQualityAlarmTrapText mandatory This text is sent in the trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.12 |
| wtWebGraphAirQualityAlarmMailOptions mandatory Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.13 |
| wtWebGraphAirQualityAlarmTcpIpAddr mandatory Name or IP address of the TCP server which accepts the trap. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.14 |
| wtWebGraphAirQualityAlarmTcpPort mandatory Port number of the TCP server which accepts the trap. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.15 |
| wtWebGraphAirQualityAlarmTcpText mandatory This text is sent in the TCP trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.16 |
| wtWebGraphAirQualityAlarmClearMailSubject mandatory Subject line for alarm clear mail. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.17 |
| wtWebGraphAirQualityAlarmClearMailText mandatory Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.18 |
| wtWebGraphAirQualityAlarmClearTrapText mandatory This text is sent in the trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.19 |
| wtWebGraphAirQualityAlarmClearTcpText mandatory This text is sent in the TCP trap body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.20 |
| wtWebGraphAirQualityAlarmDeltaTemp mandatory Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.21 |
| wtWebGraphAirQualityAlarmRHMin mandatory Minimum rel. Humidity in percent with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.22 |
| wtWebGraphAirQualityAlarmRHMax mandatory Maximum rel.Humidity in percent with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.23 |
| wtWebGraphAirQualityAlarmRHHysteresis mandatory Hysteresis of rel. Humidity in percent with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.24 |
| wtWebGraphAirQualityAlarmAHMin mandatory Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.25 |
| wtWebGraphAirQualityAlarmAHMax mandatory Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.26 |
| wtWebGraphAirQualityAlarmSyslogIpAddr mandatory IP address of the syslog server to which the Webio device should send syslog messages. | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.27 |
| wtWebGraphAirQualityAlarmSyslogPort mandatory Port number of the syslog server to which the Webio device should send syslog messages. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.28 |
| wtWebGraphAirQualityAlarmSyslogText mandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.29 |
| wtWebGraphAirQualityAlarmMax mandatory Maximum temperature in degrees with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.3 |
| wtWebGraphAirQualityAlarmSyslogClearText mandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.30 |
| wtWebGraphAirQualityAlarmFtpDataPort mandatory Local data port: 1..65535 or AUTO: the next free port will be assigned. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.31 |
| wtWebGraphAirQualityAlarmFtpFileName mandatory Name of the file including path informations. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.32 |
| wtWebGraphAirQualityAlarmFtpText mandatory Message text to store on the FTP server. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.33 |
| wtWebGraphAirQualityAlarmFtpClearText mandatory Alarm clear message to store on the FTP server. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.34 |
| wtWebGraphAirQualityAlarmFtpOption mandatory Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.35 |
| wtWebGraphAirQualityAlarmTimerCron mandatory This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are… | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.36 |
| wtWebGraphAirQualityAlarmVocMax mandatory Maximum VOC in ppm with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.37 |
| wtWebGraphAirQualityAlarmVocHysteresis mandatory Hysteresis of VOC in ppm with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.38 |
| wtWebGraphAirQualityAlarmName mandatory Alert name | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.39 |
| wtWebGraphAirQualityAlarmHysteresis mandatory Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.4 |
| wtWebGraphAirQualityAlarmActive mandatory Alert active
1 = ON
0 = OFF | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.40 |
| wtWebGraphAirQualityAlarmDelay mandatory Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.5 |
| wtWebGraphAirQualityAlarmInterval mandatory Send interval for alarm messages. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.6 |
| wtWebGraphAirQualityAlarmHttpReqAuthEnable mandatory Binary coded options, select only one option at the same time:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.61 |
| wtWebGraphAirQualityAlarmHttpReqAuthUser mandatory HTTP Request: User | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.62 |
| wtWebGraphAirQualityAlarmHttpReqAuthPassword mandatory HTTP Request: Password | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.63 |
| wtWebGraphAirQualityAlarmHttpReqSetUrl mandatory HTTP Request: Set URL | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.64 |
| wtWebGraphAirQualityAlarmHttpReqClearUrl mandatory HTTP Request: Clear URL | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.65 |
| wtWebGraphAirQualityAlarmHttpReqServerPort mandatory HTTP Request: Server Port | column | Integer32 | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.66 |
| wtWebGraphAirQualityAlarmMqttTopicPath mandatory MQTT Publish: Topic path | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.67 |
| wtWebGraphAirQualityAlarmMqttTopicSetTopic mandatory MQTT Publish: Topic SET message | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.68 |
| wtWebGraphAirQualityAlarmMqttTopicClear mandatory MQTT Publish: Topic CLEAR message | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.69 |
| wtWebGraphAirQualityAlarmEnable mandatory Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.7 |
| wtWebGraphAirQualityAlarmSensorLostSelection mandatory Binary coded options:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 3-7: unused
Bit 2 : Sensor 2
Bit 1 : Sensor 1
Bit 0 : Sensor 0 | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.70 |
| wtWebGraphAirQualityAlarmLimitWindow mandatory If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE
the alarm is generated when t… | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.71 |
| wtWebGraphAirQualityAlarmEMailAddr mandatory E-Mail address for sending the alarm mail to. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.8 |
| wtWebGraphAirQualityAlarmMailSubject mandatory Subject line for alarm mail. | column | OctetString | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.9 |