SUPERMICRO-HEALTH-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
12
.1.3.6.1.4.1.10876.2.1.1.1 · 1 row entry · 12 columns
A table of health monitoring entries.
smHealthMonitorEntry entry .1.3.6.1.4.1.10876.2.1.1.1.1
An entry in the health monitoring table.
Entries cannot be created or deleted via SNMP operations.
Indexes
smHealthMonitorIndex
Column Syntax OID
smHealthMonitorIndex
The unique value identifies this Monitor device.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.1
smHealthMonitorName
A textual full name assigned to the Monitor device.
This object is suitable for output to a human operator.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10876.2.1.1.1.1.2
smHealthMonitorType
Identifies this Monitor device type.
SMHealthInfoTypes
Textual Convention: SMHealthInfoTypes Integer32
Type Constraints:
range: 0..64
.1.3.6.1.4.1.10876.2.1.1.1.1.3
smHealthMonitorReading
Indicates the reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture readings are displayed in Celsius.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.4
smHealthMonitorHighLimit
Indicates the the High limit for the Monitor device that are currently in use on the managed device.
This is applied to Temperature and Voltage devices only.
Voltage limit is displayed in mV, and Temperture limit is dis…
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.5
smHealthMonitorLowLimit
Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device.
FAN limit is displayed in RPM, Voltage limit is displayed in mV, and Temperture limit is displayed in Ce…
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.6
smHealthMonitorMaxReading
Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture read…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.7
smHealthMonitorMinReading
Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temperture read…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.10876.2.1.1.1.1.8
smHealthMonitorDivisor
Indicates the value for the Divisor for the Fan device that are currently in use on the managed device.
This is applied to Fan devices only.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10876.2.1.1.1.1.9
smHealthMonitorMonitor
Indicates the monitoring status for the Fan device that are currently in use on the managed device.
0 = not monitored, 1 = monitored.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.10876.2.1.1.1.1.10
smHealthMonitorReadingUnit
Indicates the reading unit of the monitor device.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10876.2.1.1.1.1.11
smHealthMonitorStatus
Indicates the status of the monitor device. Values:
0: OK
1: Warning
2: Critical
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647