smHealthMonitorIndex
SUPERMICRO-HEALTH-MIB ·
.1.3.6.1.4.1.10876.2.1.1.1.1.1
Object
column
Integer32
The unique value identifies this Monitor device.
Context
- MIB
- SUPERMICRO-HEALTH-MIB
- OID
.1.3.6.1.4.1.10876.2.1.1.1.1.1- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- smHealthMonitorEntry
- Table
- smHealthMonitorTable
- Siblings
- 11
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-65535
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| smHealthMonitorMonitor Indicates the monitoring status for the Fan device that are currently in use on the managed device.
0 = not monitored, 1 = monitored. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.10876.2.1.1.1.1.10 |
| smHealthMonitorReadingUnit Indicates the reading unit of the monitor device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.2.1.1.1.1.11 |
| smHealthMonitorStatus Indicates the status of the monitor device. Values:
0: OK
1: Warning
2: Critical | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10876.2.1.1.1.1.12 |
| smHealthMonitorName A textual full name assigned to the Monitor device.
This object is suitable for output to a human operator. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.2.1.1.1.1.2 |
| smHealthMonitorType Identifies this Monitor device type. | column | SMHealthInfoTypes | .1.3.6.1.4.1.10876.2.1.1.1.1.3 |
| smHealthMonitorReading Indicates the reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readings are displayed in mV.
Temper… | column | Integer32 | .1.3.6.1.4.1.10876.2.1.1.1.1.4 |
| smHealthMonitorHighLimit Indicates the the High limit for the Monitor device that are currently in use on the managed device.
This is applied to Temperature and Voltage devices only.
Voltage limit is disp… | column | Integer32 | .1.3.6.1.4.1.10876.2.1.1.1.1.5 |
| smHealthMonitorLowLimit Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device.
FAN limit is displayed in RPM, Voltage limit is displayed in mV,… | column | Integer32 | .1.3.6.1.4.1.10876.2.1.1.1.1.6 |
| smHealthMonitorMaxReading Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readi… | column | Integer32 | .1.3.6.1.4.1.10876.2.1.1.1.1.7 |
| smHealthMonitorMinReading Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device.
FAN readings are displayed in RPM.
Voltage readi… | column | Integer32 | .1.3.6.1.4.1.10876.2.1.1.1.1.8 |
| smHealthMonitorDivisor Indicates the value for the Divisor for the Fan device that are currently in use on the managed device.
This is applied to Fan devices only. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10876.2.1.1.1.1.9 |