SPC200 Table View

Table-centric layout grouping table, row, and column objects.

Tables
16
Rows
16
Columns
83
.1.3.6.1.4.1.22764.1.1.1.2 · 1 row entry · 5 columns
This table gathers all statistic data specific 
to SPC200 chip relative to plc connection.
portStatsEntry entry .1.3.6.1.4.1.22764.1.1.1.2.1
This row contains statistic data specific to
SPC200 chip relative to a connection.
Indexes
plcBasePortIndex portStatsBandIndex portStatsGroupIndex portStatsCarrierIndex
Column Syntax OID
portStatsBandIndex
The band number on which the signal,
noise, ber data are collected.
BandValue
Textual Convention: BandValue Integer32
Type Constraints:
range: 1..7
.1.3.6.1.4.1.22764.1.1.1.2.1.1
portStatsGroupIndex
The group number on which the signal,
noise, ber data are collected
GroupValue
Textual Convention: GroupValue Integer32
Type Constraints:
range: 1..16
.1.3.6.1.4.1.22764.1.1.1.2.1.2
portStatsCarrierIndex
The group number on which the signal,
noise, ber data are collected
CarrierValue
Textual Convention: CarrierValue Integer32
Type Constraints:
range: 1..8
.1.3.6.1.4.1.22764.1.1.1.2.1.3
portStatsSignal
The DB value of the signal associated
with the carrier wave entry.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.1.2.1.4
portStatsNoise
The DB value of the noise associated
with the carrier wave entry.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.1.2.1.5
.1.3.6.1.4.1.22764.1.1.1.3 · 1 row entry · 4 columns
This table gathers all statistic data specific to 
SPC200 chip relative to plc channels. This table has 
the same information as the portChannelStatsTable 
but in a more compact way. This table has been added 
to deal with possible slow performances.
portStats2Entry entry .1.3.6.1.4.1.22764.1.1.1.3.1
This row contains statistic data specific to
SPC200 chip relative to a connection.
Indexes
plcBasePortIndex plcModBandIndex
Column Syntax OID
portStats2Signal
The values of the signal for all the carrier waves.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is coded on two bytes.
There is one value for each 128 carriers of the
considered band.
OctetString .1.3.6.1.4.1.22764.1.1.1.3.1.1
portStats2Noise
The values of the noise for all the carrier waves.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is coded on two bytes.
There is one value for each 128 carriers of the
considered band.
OctetString .1.3.6.1.4.1.22764.1.1.1.3.1.2
portStats2AvgBandAtt
Average attenuation per band (dB).
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.1.3.1.3
portStats2AvgBandSNR
Average SNR per band (dB).
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.1.3.1.4
.1.3.6.1.4.1.22764.1.1.1.4 · 1 row entry · 2 columns
This table gathers all statistic data specific to 
SPC200 chip relative to plc channels. This table has 
the same information as the portChannelStatsTable 
but in a more compact way. This table has been added 
to deal with possible slow performances.
portStats3Entry entry .1.3.6.1.4.1.22764.1.1.1.4.1
This row contains statistic data specific to
SPC200 chip relative to a connection.
Indexes
plcBasePortIndex
Column Syntax OID
portStats3AvgAtt
Average attenuation on the link (dB).
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.1.4.1.1
portStats3AvgSNR
Average SNR on the link (dB).
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.1.4.1.2
.1.3.6.1.4.1.22764.1.1.2.2.2 · 1 row entry · 4 columns
This table contains the list of plc remote connection
plcBasePortEntry entry .1.3.6.1.4.1.22764.1.1.2.2.2.1
This row contains plc remote connection information
Indexes
plcBasePortIndex
Column Syntax OID
plcBasePortIndex
The MAC address of the MAC layer above
the plc interface of the remote PLC equipment.
SNMPv2-TCMacAddress
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.22764.1.1.2.2.2.1.1
plcBasePortAddress
The MAC address of the MAC layer above
the plc interface of the remote PLC equipment.
SNMPv2-TCMacAddress
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.22764.1.1.2.2.2.1.2
plcBasePortChannelEstimation
Enable or disable the automatic channel
estimation processus.
EstimationModer/w
Textual Convention: EstimationMode Enumeration
Type Values:
1automatic
2manual
.1.3.6.1.4.1.22764.1.1.2.2.2.1.3
plcBasePortAttenuation
Link attenuation (dB).
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.2.2.2.1.4
.1.3.6.1.4.1.22764.1.1.2.2.3 · 1 row entry · 3 columns
This table contains string values for a quick access to
the modulation amplitude configurations of all active
channels.
plcChannelModulationStringEntry entry .1.3.6.1.4.1.22764.1.1.2.2.3.1
This row contains string values for a quick access to
the modulation amplitude configuration
of each active channel of the remote
connection referenced by plcBasePortIndex.
Indexes
plcBasePortIndex
Column Syntax OID
plcRxChannelModulation
The modulation amplitude values for the Rx channel of
a given remote connection entry.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is an octet representing two modulation values.
Each modulation is c…
OctetString .1.3.6.1.4.1.22764.1.1.2.2.3.1.1
plcRxLastChannelModulation
The modulation amplitude values for the Rx Last channel of
a given remote connection entry.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is an octet representing two modulation values.
Each modulation…
OctetString .1.3.6.1.4.1.22764.1.1.2.2.3.1.2
plcTxChannelModulation
The modulation amplitude values for the Tx channel of
a given remote connection entry.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is an octet representing two modulation values.
Each modulation is c…
OctetString .1.3.6.1.4.1.22764.1.1.2.2.3.1.3
.1.3.6.1.4.1.22764.1.1.2.2.4 · 1 row entry · 17 columns
This table contains the modulation amplitude 
configuration of all active channels.
plcChannelModulationEntry entry .1.3.6.1.4.1.22764.1.1.2.2.4.1
This row contains modulation amplitude configuration
of the channel, referenced by the plcPortChannelIndex,
of the remote connection referenced by
plcBasePortIndex.
Indexes
plcBasePortIndex plcPortChannelIndex plcModBandIndex
Column Syntax OID
plcModBandIndex
The band number of which the modulations are defined
BandValue
Textual Convention: BandValue Integer32
Type Constraints:
range: 1..7
.1.3.6.1.4.1.22764.1.1.2.2.4.1.1
plcModGroup1
The modulation amplitude of the first group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.2
plcModGroup2
The modulation amplitude of the second group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.3
plcModGroup3
The modulation amplitude of the third group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.4
plcModGroup4
The modulation amplitude of the fourth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.5
plcModGroup5
The modulation amplitude of the fifth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.6
plcModGroup6
The modulation amplitude of the sixth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.7
plcModGroup7
The modulation amplitude of the seventh group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.8
plcModGroup8
The modulation amplitude of the eighth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.9
plcModGroup9
The modulation amplitude of the nineth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.10
plcModGroup10
The modulation amplitude of the tenth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.11
plcModGroup11
The modulation amplitude of the eleventh group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.12
plcModGroup12
The modulation amplitude of the twelveth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.13
plcModGroup13
The modulation amplitude of the thirteenth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.14
plcModGroup14
The modulation amplitude of the fourteenth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.15
plcModGroup15
The modulation amplitude of the fifteenth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.16
plcModGroup16
The modulation amplitude of the sixteenth group
of the band entry of the channel entry
for a given remote connection entry.
ModulationValue
Textual Convention: ModulationValue Enumeration
Type Values:
1none
2bpsk
3qpsk
4qam16
5qam64
6qam256
.1.3.6.1.4.1.22764.1.1.2.2.4.1.17
.1.3.6.1.4.1.22764.1.1.2.2.6 · 1 row entry · 6 columns
This table contains the list of plc channels
plcPortChannelEntry entry .1.3.6.1.4.1.22764.1.1.2.2.6.1
This row contains plc channel information
Indexes
plcBasePortIndex plcPortChannelIndex
Column Syntax OID
plcPortChannelIndex
The channel number belongs to the remote connection
with plc equipment associated with the
plcBasePortIndex value.
Only three channels are expected.
Index 1 for RX channel
Index 2 for RXLast channel
index 3 fo…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.2.2.6.1.1
plcPortChannelType
The channel type.
PlcChannelType
Textual Convention: PlcChannelType Enumeration
Type Values:
1rx
2rxLast
3tx
.1.3.6.1.4.1.22764.1.1.2.2.6.1.2
plcPortChannelGain
The gain associated with the channel.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.22764.1.1.2.2.6.1.3
plcPortChannelBandwidth
The bandwidth of the channel in Kbit/s.
ChannelBandwidthValue
Textual Convention: ChannelBandwidthValue Integer32
.1.3.6.1.4.1.22764.1.1.2.2.6.1.4
plcPortChannelMaxBandwidth
The maximum bandwidth of the channel in Kbit/s.
ChannelBandwidthValue
Textual Convention: ChannelBandwidthValue Integer32
.1.3.6.1.4.1.22764.1.1.2.2.6.1.5
plcPortChannelSynchronizationBand
The synchronization band used for this channel.
BandValue
Textual Convention: BandValue Integer32
Type Constraints:
range: 1..7
.1.3.6.1.4.1.22764.1.1.2.2.6.1.6
.1.3.6.1.4.1.22764.1.1.2.2.7 · 1 row entry · 3 columns
This table contains the string values representing
of pilot values of all active channels.
plcChannelPilotStringEntry entry .1.3.6.1.4.1.22764.1.1.2.2.7.1
This row contains a quick access for pilot values ,
of the remote connection referenced by
plcBasePortIndex.
Indexes
plcBasePortIndex
Column Syntax OID
plcRxChannelPilots
The carrier wave numbers which support
the pilot waves for the Rx Channel.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is a pair of octets representing the pilot
values. There is one pair (pilot1 p…
OctetString .1.3.6.1.4.1.22764.1.1.2.2.7.1.1
plcRxLastChannelPilots
The carrier wave numbers which support
the pilot waves for the Rx Last Channel.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is a pair of octets representing the pilot
values. There is one pair (pil…
OctetString .1.3.6.1.4.1.22764.1.1.2.2.7.1.2
plcTxChannelPilots
The carrier wave numbers which support
the pilot waves for the Tx Channel.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is a pair of octets representing the pilot
values. There is one pair (pilot1 p…
OctetString .1.3.6.1.4.1.22764.1.1.2.2.7.1.3
.1.3.6.1.4.1.22764.1.1.2.2.8 · 1 row entry · 3 columns
This tabel contains pilots configuration 
for each plc channel.
plcChannelPilotsEntry entry .1.3.6.1.4.1.22764.1.1.2.2.8.1
This row contains the pilots 1 and 2 configuration
for a channel defined by the
couple (plcBasePortIndex, plcPortChannelIndex)
Indexes
plcBasePortIndex plcPortChannelIndex plcChannelPilotBandIndex
Column Syntax OID
plcChannelPilotBandIndex
The band number on which the pilots are defined.
BandValue
Textual Convention: BandValue Integer32
Type Constraints:
range: 1..7
.1.3.6.1.4.1.22764.1.1.2.2.8.1.1
plcChannelPilot1
The carrier wave number which supports
the first pilot wave for the channel
associated with this entry.
PilotValue
Textual Convention: PilotValue Integer32
Type Constraints:
range: 1..128
.1.3.6.1.4.1.22764.1.1.2.2.8.1.2
plcChannePilot2
The carrier wave number which supports
the second pilot wave for the channel
associated with this entry.
PilotValue
Textual Convention: PilotValue Integer32
Type Constraints:
range: 1..128
.1.3.6.1.4.1.22764.1.1.2.2.8.1.3
.1.3.6.1.4.1.22764.1.1.2.3.2 · 1 row entry · 10 columns
This table contains Notches configuration 
for the SPC200 chip.
plcNodeNotchesEntry entry .1.3.6.1.4.1.22764.1.1.2.3.2.1
This row contains Notches configuration for a group.
The group is defined by the couple
(plcNodeNotchesGroupIndex, plcNodeNotchesBandIndex).
Indexes
plcNodeNotchesBandIndex plcNodeNotchesGroupIndex
Column Syntax OID
plcNodeNotchesBandIndex
The band number on which the notches are defined.
BandValue
Textual Convention: BandValue Integer32
Type Constraints:
range: 1..7
.1.3.6.1.4.1.22764.1.1.2.3.2.1.1
plcNodeNotchesGroupIndex
The group number on which the notches are defined.
GroupValue
Textual Convention: GroupValue Integer32
Type Constraints:
range: 1..16
.1.3.6.1.4.1.22764.1.1.2.3.2.1.2
plcNodeNotchesCarrier1
Tell if the first carrier of the group entry
of the band entry is a notch carrier.
The true value means the current carrier is a notch.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22764.1.1.2.3.2.1.3
plcNodeNotchesCarrier2
Tell if the second carrier of the group entry
of the band entry is a notch carrier.
The true value means the current carrier is a notch.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22764.1.1.2.3.2.1.4
plcNodeNotchesCarrier3
Tell if the third carrier of the group entry
of the band entry is a notch carrier.
The true value means the current carrier is a notch.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22764.1.1.2.3.2.1.5
plcNodeNotchesCarrier4
Tell if the fourth carrier of the group entry
of the band entry is a notch carrier.
The true value means the current carrier is a notch.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22764.1.1.2.3.2.1.6
plcNodeNotchesCarrier5
Tell if the fifth carrier of the group entry
of the band entry is a notch carrier.
The true value means the current carrier is a notch.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22764.1.1.2.3.2.1.7
plcNodeNotchesCarrier6
Tell if the sixth carrier of the group entry
of the band entry is a notch carrier.
The true value means the current carrier is a notch.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22764.1.1.2.3.2.1.8
plcNodeNotchesCarrier7
Tell if the seventh carrier of the group entry
of the band entry is a notch carrier.
The true value means the current carrier is a notch.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22764.1.1.2.3.2.1.9
plcNodeNotchesCarrier8
Tell if the eighth carrier of the group entry
of the band entry is a notch carrier.
The true value means the current carrier is a notch.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22764.1.1.2.3.2.1.10
.1.3.6.1.4.1.22764.1.1.2.3.5 · 1 row entry · 3 columns
This table contains pilot values 
used by default on all channels.
plcNodePilotsEntry entry .1.3.6.1.4.1.22764.1.1.2.3.5.1
This row contains pilot values
used by default on a band.
The band is defined by the index
plcNodePilotsBandIndex.
Indexes
plcNodePilotsBandIndex
Column Syntax OID
plcNodePilotsBandIndex
The band number on which the pilot values are defined.
BandValue
Textual Convention: BandValue Integer32
Type Constraints:
range: 1..7
.1.3.6.1.4.1.22764.1.1.2.3.5.1.1
plcNodePilot1
The default carrier wave number
which supports the first pilot wave.
PilotValue
Textual Convention: PilotValue Integer32
Type Constraints:
range: 1..128
.1.3.6.1.4.1.22764.1.1.2.3.5.1.2
plcNodePilot2
The default carrier wave number
which supports the second pilot wave.
PilotValue
Textual Convention: PilotValue Integer32
Type Constraints:
range: 1..128
.1.3.6.1.4.1.22764.1.1.2.3.5.1.3
.1.3.6.1.4.1.22764.1.1.2.3.7 · 1 row entry · 2 columns
This table contains string values for a 
quick access to the adapt configurations 
of all the carriers.
plcNodeAdaptsStringEntry entry .1.3.6.1.4.1.22764.1.1.2.3.7.1
This row contains string values for a quick access to
the adapt configuration
of each carrier of a band.
Indexes
plcBasePortIndex plcNodeAdaptsStringBandIndex
Column Syntax OID
plcNodeAdaptsStringBandIndex
The band number on which the adapt values are defined.
BandValue
Textual Convention: BandValue Integer32
Type Constraints:
range: 1..7
.1.3.6.1.4.1.22764.1.1.2.3.7.1.1
plcNodeAdaptsStringBand
The adapt values of the 128 carriers of a band.
The expected format is VALUE VALUE VALUE ... VALUE.
Each value is two octets representing one adapt carrier
level.
There are ( 16 groups * 8 carriers) = 128 values.
OctetString .1.3.6.1.4.1.22764.1.1.2.3.7.1.2
.1.3.6.1.4.1.22764.1.1.2.3.8 · 1 row entry · 10 columns
This table contains adapt level configuration 
for each carrier of the node.
plcNodeAdaptsEntry entry .1.3.6.1.4.1.22764.1.1.2.3.8.1
This row contains adapt level values
for a group of carriers.
The group is defined by the couple
(plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex).
Indexes
plcNodeAdaptsBandIndex plcNodeAdaptsGroupIndex
Column Syntax OID
plcNodeAdaptsBandIndex
The band number on which the adapt values are defined.
BandValue
Textual Convention: BandValue Integer32
Type Constraints:
range: 1..7
.1.3.6.1.4.1.22764.1.1.2.3.8.1.1
plcNodeAdaptsGroupIndex
The group number on which the adapt values are defined.
GroupValue
Textual Convention: GroupValue Integer32
Type Constraints:
range: 1..16
.1.3.6.1.4.1.22764.1.1.2.3.8.1.2
plcNodeAdaptsCarrier1
The adapt level of the first carrier of the group.
AdaptValue
Textual Convention: AdaptValue Integer32
Type Constraints:
range: 0..8191
.1.3.6.1.4.1.22764.1.1.2.3.8.1.3
plcNodeAdaptsCarrier2
The adapt level of the second carrier of the group.
AdaptValue
Textual Convention: AdaptValue Integer32
Type Constraints:
range: 0..8191
.1.3.6.1.4.1.22764.1.1.2.3.8.1.4
plcNodeAdaptsCarrier3
The adapt level of the third carrier of the group.
AdaptValue
Textual Convention: AdaptValue Integer32
Type Constraints:
range: 0..8191
.1.3.6.1.4.1.22764.1.1.2.3.8.1.5
plcNodeAdaptsCarrier4
The adapt level of the fourth carrier of the group.
AdaptValue
Textual Convention: AdaptValue Integer32
Type Constraints:
range: 0..8191
.1.3.6.1.4.1.22764.1.1.2.3.8.1.6
plcNodeAdaptsCarrier5
The adapt level of the fifth carrier of the group.
AdaptValue
Textual Convention: AdaptValue Integer32
Type Constraints:
range: 0..8191
.1.3.6.1.4.1.22764.1.1.2.3.8.1.7
plcNodeAdaptsCarrier6
The adapt level of the sixth carrier of the group.
AdaptValue
Textual Convention: AdaptValue Integer32
Type Constraints:
range: 0..8191
.1.3.6.1.4.1.22764.1.1.2.3.8.1.8
plcNodeAdaptsCarrier7
The adapt level of the seventh carrier of the group.
AdaptValue
Textual Convention: AdaptValue Integer32
Type Constraints:
range: 0..8191
.1.3.6.1.4.1.22764.1.1.2.3.8.1.9
plcNodeAdaptsCarrier8
The adapt level of the eighth carrier of the group.
AdaptValue
Textual Convention: AdaptValue Integer32
Type Constraints:
range: 0..8191
.1.3.6.1.4.1.22764.1.1.2.3.8.1.10
.1.3.6.1.4.1.22764.1.1.2.3.10 · 1 row entry · 4 columns
This table contains ip and mac 
addresses of the node.
plcNodeNetConfigEntry entry .1.3.6.1.4.1.22764.1.1.2.3.10.1
This row contains ip and mac address
used by an interface.
Indexes
IF-MIBifIndex
Column Syntax OID
plcNodeIpAddr
The IP address of the IP layer above the interface.
SNMPv2-SMIIpAddressr/w
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.22764.1.1.2.3.10.1.1
plcNodeNetMask
The IP Subnet mask of the IP layer above the interface.
SNMPv2-SMIIpAddressr/w
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.22764.1.1.2.3.10.1.2
plcNodeMacAddr
The MAC address of the MAC layer above the interface.
SNMPv2-TCMacAddressr/w
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.22764.1.1.2.3.10.1.3
plcNodeGateway
The Gateway address of the IP layer above the interface.
SNMPv2-SMIIpAddressr/w
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.22764.1.1.2.3.10.1.4
.1.3.6.1.4.1.22764.1.1.2.4.2 · 1 row entry · 5 columns
This table gathers all statistic data specific to 
SPC200 chip relative to plc analyser.
plcSNAnalyserEntry entry .1.3.6.1.4.1.22764.1.1.2.4.2.1
This row contains statistic data specific to
SPC200 chip relative to a band.
Indexes
plcModBandIndex
Column Syntax OID
plcSNAnalyserMinSignal
Minimum signal measured over several samples for the
associated carrier wave entry. The value is expressed
in Glomer� which can be converted in dBm/Hz using the
following formula: dBm/Hz = 19*log10(Glomer�) - 113
OctetString .1.3.6.1.4.1.22764.1.1.2.4.2.1.1
plcSNAnalyserMaxSignal
Maximum signal measured on several samples for the
associated carrier wave entry. The value is expressed
in Glomer� which can be converted in dBm/Hz using the
following formula: dBm/Hz = 19*log10(Glomer�) - 113
OctetString .1.3.6.1.4.1.22764.1.1.2.4.2.1.2
plcSNAnalyserAvgSignal
Average signal measured on several samples for the
associated carrier wave entry. The value is expressed
in Glomer� which can be converted in dBm/Hz using the
following formula: dBm/Hz = 19*log10(Glomer�) - 113
OctetString .1.3.6.1.4.1.22764.1.1.2.4.2.1.3
plcSNAnalyserLastSignal
Signal measured for last sample on the associated
carrier wave entry. The value is expressed
in Glomer� which can be converted in dBm/Hz using the
following formula: dBm/Hz = 19*log10(Glomer�) - 113
OctetString .1.3.6.1.4.1.22764.1.1.2.4.2.1.4
plcSNAnalyserFFTDiv
FFT division factor on the associated band.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.22764.1.1.2.4.2.1.5
.1.3.6.1.4.1.22764.1.1.3.4 · 1 row entry · 2 columns
This table contains the current and reserve 
softwares of the node.
softwareEntry entry .1.3.6.1.4.1.22764.1.1.3.4.1
This row contains software information.
Indexes
softwareIndex
Column Syntax OID
softwareIndex
The index number of the software.
SoftwareIndex
Textual Convention: SoftwareIndex Integer32
Type Constraints:
range: 1..10
.1.3.6.1.4.1.22764.1.1.3.4.1.1
softwareVersion
The name of the software release.
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.22764.1.1.3.4.1.2